These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

155 related articles for article (PubMed ID: 9138327)

  • 1. [Experimental protocol for mechanical characterization of a femoral implant of carbon-Peek composite hip prosthesis in fatigue].
    Soyer J
    Chirurgie; 1997 Jan; 121(9-10):658-62. PubMed ID: 9138327
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterization of wear in composite material orthopaedic implants. Part I: The composite trunnion/ceramic head interface.
    Maharaj G; Bleser S; Albert K; Lambert R; Jani S; Jamison R
    Biomed Mater Eng; 1994; 4(3):193-8. PubMed ID: 7950868
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characterization of wear in composite material orthopaedic implants. Part II: The implant/bone interface.
    Albert K; Schledjewski R; Harbaugh M; Bleser S; Jamison R; Friedrich K
    Biomed Mater Eng; 1994; 4(3):199-211. PubMed ID: 7950869
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Strain distribution in the proximal femur with flexible composite and metallic femoral components under axial and torsional loads.
    Otani T; Whiteside LA; White SE
    J Biomed Mater Res; 1993 May; 27(5):575-85. PubMed ID: 8314810
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Composite technology for total hip arthroplasty.
    Skinner HB
    Clin Orthop Relat Res; 1988 Oct; (235):224-36. PubMed ID: 3416528
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Mechanical stability of hip joint endoprosthesis shafts of carbon fiber composite materials].
    Kaddick C; Ascherl R; Siebels W; Brüller O; Blümel G
    Z Orthop Ihre Grenzgeb; 1996; 134(2):111-6. PubMed ID: 8779253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The application of new composite materials for total joint arthroplasty.
    Mukherjee DP; Saha S
    J Long Term Eff Med Implants; 1993; 3(2):131-41. PubMed ID: 10146540
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The influence of sterilization processes on the micromechanical properties of carbon fiber-reinforced PEEK composites for bone implant applications.
    Godara A; Raabe D; Green S
    Acta Biomater; 2007 Mar; 3(2):209-20. PubMed ID: 17236831
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stiffness optimisation of cement and stem materials in total hip replacement.
    Hedia HS
    Biomed Mater Eng; 2001; 11(1):1-10. PubMed ID: 11281574
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of optimized epoxy graphite implant for the total hip joint.
    Iyer LS; Jayasekaran T; Blunck CF; Selvam RP
    ISA Trans; 1984; 23(2):7-14. PubMed ID: 6746263
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Fracture toughness and fatigue crack propagation rate of short fiber reinforced epoxy composites for analogue cortical bone.
    Chong AC; Miller F; Buxton M; Friis EA
    J Biomech Eng; 2007 Aug; 129(4):487-93. PubMed ID: 17655469
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Conus hip prosthesis.
    Wagner H; Wagner M
    Acta Chir Orthop Traumatol Cech; 2001; 68(4):213-21. PubMed ID: 11706545
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The European school of total hip arthroplasty and 35 years of total hip arthroplasty in the Czech Republic.
    Cech O; Dzupa V
    Acta Chir Orthop Traumatol Cech; 2005; 72(1):57-76. PubMed ID: 15860155
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation and comparison of polyetheretherketone rod system to traditional titanium rod fixation.
    Ponnappan RK; Serhan H; Zarda B; Patel R; Albert T; Vaccaro AR
    Spine J; 2009 Mar; 9(3):263-7. PubMed ID: 18838341
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Migration and cyclic motion of a new short-stemmed hip prosthesis--a biomechanical in vitro study.
    Westphal FM; Bishop N; Honl M; Hille E; Püschel K; Morlock MM
    Clin Biomech (Bristol, Avon); 2006 Oct; 21(8):834-40. PubMed ID: 16806616
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Cementless socket fixation based on the "press-fit" concept in total hip joint arthroplasty].
    Morscher EW; Widmer KH; Bereiter H; Elke R; Schenk R
    Acta Chir Orthop Traumatol Cech; 2002; 69(1):8-15. PubMed ID: 11951572
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Stiffness and strength tailoring of a hip prosthesis made of advanced composite materials.
    Chang FK; Perez JL; Davidson JA
    J Biomed Mater Res; 1990 Jul; 24(7):873-99. PubMed ID: 2398076
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Influence of proximal stem geometry and stem-cement interface characteristics on bone and cement stresses in femoral hip arthroplasty: finite element analysis].
    Massin P; Astoin E; Lavaste F
    Rev Chir Orthop Reparatrice Appar Mot; 2003 Apr; 89(2):134-43. PubMed ID: 12844057
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Influence of airborne-particle abrasion on mechanical properties and bond strength of carbon/epoxy and glass/bis-GMA fiber-reinforced resin posts.
    Soares CJ; Santana FR; Pereira JC; Araujo TS; Menezes MS
    J Prosthet Dent; 2008 Jun; 99(6):444-54. PubMed ID: 18514666
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.