These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
653 related articles for article (PubMed ID: 914142)
21. Phonocardiographic findings in patients with normally functioning Ionescu-Shiley prostheses. Szkopiec RL; Desser KB; Benchimol A; Sheasby C Am J Cardiol; 1983 Mar; 51(6):969-72. PubMed ID: 6829474 [TBL] [Abstract][Full Text] [Related]
22. Frequency content of heart sounds and systolic murmurs in patients with porcine bioprosthetic valves: diagnostic value for the early detection of valvular degeneration. Stein PD; Sabbah HN; Lakier JB; Kemp SR; Magilligan DJ Henry Ford Hosp Med J; 1982; 30(3):119-23. PubMed ID: 7161125 [No Abstract] [Full Text] [Related]
23. Closing click of St Jude Medical and Duromedics Edwards bileaflet valves: complaints created by valve noise and their relation to sound pressure and hearing level. Moritz A; Steinseifer U; Kobina G; Neuwirth-Riedl K; Wolters H; Reul H; Wolner E Eur Heart J; 1991 Jun; 12(6):673-9. PubMed ID: 1860467 [TBL] [Abstract][Full Text] [Related]
25. First-degree atrioventricular block: a cause of false malfunction of a mitral disc-valve prosthesis. Case report. Stefadouros MA; Smith WS; Fraser RC; Hitch W; Rubin JW J Thorac Cardiovasc Surg; 1975 May; 69(5):776-80. PubMed ID: 1127976 [TBL] [Abstract][Full Text] [Related]
26. The evaluation of common heart murmurs in the adult by noninvasive techniques. Siegel W Cardiovasc Clin; 1975; 7(1):157-68. PubMed ID: 1149059 [No Abstract] [Full Text] [Related]
28. Atypical phonocardiographic presentation of a patient with congenital aortic insufficiency. Kerin N; Davis B; Schwartz H Am Heart J; 1975 Jul; 90(1):75-7. PubMed ID: 1136941 [No Abstract] [Full Text] [Related]
29. A decision tree--based method for the differential diagnosis of Aortic Stenosis from Mitral Regurgitation using heart sounds. Pavlopoulos SA; Stasis AC; Loukis EN Biomed Eng Online; 2004 Jun; 3(1):21. PubMed ID: 15225347 [TBL] [Abstract][Full Text] [Related]
30. [Systolic time intervals and sound level differences between the opening and closing sounds of Starr-Edwards aortic valve prostheses (author's transl)]. Aigner A; Müller G; Knapp E; Raas E Wien Klin Wochenschr; 1974 Oct; 86(19):559-61. PubMed ID: 4432513 [No Abstract] [Full Text] [Related]
31. [Noise origin and noise-induced complaints after heart valve replacement with mechanical prostheses]. Moritz A; Kobinia G; Steinseifer U; Neuwirth-Riedl K; Reul H; Windisch A; Föger A; Wolner E Wien Klin Wochenschr; 1991; 103(12):351-6. PubMed ID: 1926862 [TBL] [Abstract][Full Text] [Related]
32. [Studies on the mechanisms of the third and fourth heart sounds: with special reference to the phase analysis of mitral flow velocity pattern]. Fukuda N; Oki T; Sakai H; Asai M; Ohshima C; Murao A; Tominaga T; Kusaka Y; Manabe K; Niki T J Cardiogr; 1983 Sep; 13(3):571-85. PubMed ID: 6678290 [TBL] [Abstract][Full Text] [Related]
33. [Auscultation and phonocardiography in acquired heart defects]. Michel D Internist (Berl); 1965 Dec; 6(12):515-29. PubMed ID: 5334459 [No Abstract] [Full Text] [Related]
34. [Auscultatory findings of heart sounds and murmurs in congenital heart anomalies and acquired valvular diseases. Special reference to the determination of the severity of the condition on the basis of phonocardiography]. Shibuya M Kyobu Geka; 1965 Dec; 18(14):1008-16. PubMed ID: 5894745 [No Abstract] [Full Text] [Related]
35. Heart sounds and murmurs in diagnosis of heart disease. Engle MA Pediatr Ann; 1981 Mar; 10(3):84-93. PubMed ID: 7220126 [No Abstract] [Full Text] [Related]
36. The value of bedside examination in an era of high technology--Part 4. Adolph RJ Heart Dis Stroke; 1994; 3(6):312-5. PubMed ID: 7850148 [No Abstract] [Full Text] [Related]
37. [Correlations between the features of first heart sound and opening snap and the shape and motion of the anterior mitral leaflet in patients with mitral stenosis]. Fukuda N; Mikawa T; Irahara K; Kawano K; Shinomiya H; Tominaga T; Okushi H; Uchida T; Oki T; Mori H J Cardiol; 1987 Mar; 17(1):77-93. PubMed ID: 3429924 [TBL] [Abstract][Full Text] [Related]
39. Distribution of aortic mechanical prosthetic valve closure sound model parameters on the surface of the chest. Baykal A; Ider YZ; Köymen H IEEE Trans Biomed Eng; 1995 Apr; 42(4):358-70. PubMed ID: 7729835 [TBL] [Abstract][Full Text] [Related]
40. Austin flint murmur associated with a disc mitral valve prosthesis. A case report. Dannheimer IP; van der Spuy JC; Ziady F S Afr Med J; 1977 Oct; 52(19):781-2. PubMed ID: 601657 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]