144 related articles for article (PubMed ID: 9141888)
1. Charnley wear model for validation of hip simulators--ball diameter versus polytetrafluoroethylene and polyethylene wear.
Clarke IC; Good V; Anissian L; Gustafson A
Proc Inst Mech Eng H; 1997; 211(1):25-36. PubMed ID: 9141888
[TBL] [Abstract][Full Text] [Related]
2. The fallacy of evaluating biomaterial wear-rates with water as lubricant: a hip simulator study of alumina-PTFE nd CoCr-PTFE combinations.
Phipatanakul WP; Johnson SA; Good V; Clarke IC
J Biomed Mater Res; 1998 Feb; 39(2):229-33. PubMed ID: 9457552
[TBL] [Abstract][Full Text] [Related]
3. Ultra-low wear rates for rigid-on-rigid bearings in total hip replacements.
Clarke IC; Good V; Williams P; Schroeder D; Anissian L; Stark A; Oonishi H; Schuldies J; Gustafson G
Proc Inst Mech Eng H; 2000; 214(4):331-47. PubMed ID: 10997055
[TBL] [Abstract][Full Text] [Related]
4. Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model.
Good VD; Clarke IC; Anissian L
J Biomed Mater Res; 1996; 33(4):275-83. PubMed ID: 8953393
[TBL] [Abstract][Full Text] [Related]
5. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of a hip joint simulator.
Smith SL; Burgess IC; Unsworth A
Proc Inst Mech Eng H; 1999; 213(6):469-73. PubMed ID: 10635695
[TBL] [Abstract][Full Text] [Related]
7. An in vitro wear study of alumina-alumina total hip prostheses.
Smith SL; Unsworth A
Proc Inst Mech Eng H; 2001; 215(5):443-6. PubMed ID: 11726044
[TBL] [Abstract][Full Text] [Related]
8. Hip-simulator ranking of polyethylene wear: comparisons between ceramic heads of different sizes.
Clarke IC; Gustafson A; Jung H; Fujisawa A
Acta Orthop Scand; 1996 Apr; 67(2):128-32. PubMed ID: 8623565
[TBL] [Abstract][Full Text] [Related]
9. A comparison between gravimetric and volumetric techniques of wear measurement of UHMWPE acetabular cups against zirconia and cobalt-chromium-molybdenum femoral heads in a hip simulator.
Smith SL; Unsworth A
Proc Inst Mech Eng H; 1999; 213(6):475-83. PubMed ID: 10635696
[TBL] [Abstract][Full Text] [Related]
10. Wear of ultra-high molecular weight polyethylene and polytetrafluoroethylene in a hip simulator: a dose-response study of protein concentration.
Good VD; Clarke IC; Gustafson GA; Downs B; Anissian L; Sorensen K
Acta Orthop Scand; 2000 Aug; 71(4):365-9. PubMed ID: 11028884
[TBL] [Abstract][Full Text] [Related]
11. Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon.
Saikko V; Ahlroos T; Calonius O; Keränen J
Biomaterials; 2001 Jun; 22(12):1507-14. PubMed ID: 11374449
[TBL] [Abstract][Full Text] [Related]
12. The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement.
Lancaster JG; Dowson D; Isaac GH; Fisher J
Proc Inst Mech Eng H; 1997; 211(1):17-24. PubMed ID: 9141887
[TBL] [Abstract][Full Text] [Related]
13. Tribological assessment of a flexible carbon-fibre-reinforced poly(ether-ether-ketone) acetabular cup articulating against an alumina femoral head.
Scholes SC; Inman IA; Unsworth A; Jones E
Proc Inst Mech Eng H; 2008 Apr; 222(3):273-83. PubMed ID: 18491697
[TBL] [Abstract][Full Text] [Related]
14. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
[TBL] [Abstract][Full Text] [Related]
15. Wear and creep of highly crosslinked polyethylene against cobalt chrome and ceramic femoral heads.
Galvin AL; Jennings LM; Tipper JL; Ingham E; Fisher J
Proc Inst Mech Eng H; 2010 Oct; 224(10):1175-83. PubMed ID: 21138235
[TBL] [Abstract][Full Text] [Related]
16. Comparison of wear of ultra-high molecular weight polyethylene acetabular cups against surface-engineered femoral heads.
Galvin A; Brockett C; Williams S; Hatto P; Burton A; Isaac G; Stone M; Ingham E; Fisher J
Proc Inst Mech Eng H; 2008 Oct; 222(7):1073-80. PubMed ID: 19024155
[TBL] [Abstract][Full Text] [Related]
17. Wear of polyethylene acetabular cups against alumina femoral heads. 5 prostheses compared in a hip simulator for 35 million walking cycles.
Saikko VO
Acta Orthop Scand; 1993 Oct; 64(5):507-12. PubMed ID: 8237313
[TBL] [Abstract][Full Text] [Related]
18. Comparison of wear, wear debris and functional biological activity of moderately crosslinked and non-crosslinked polyethylenes in hip prostheses.
Endo M; Tipper JL; Barton DC; Stone MH; Ingham E; Fisher J
Proc Inst Mech Eng H; 2002; 216(2):111-22. PubMed ID: 12022418
[TBL] [Abstract][Full Text] [Related]
19. Comparison of the wear rates of twenty-eight and thirty-two-millimeter femoral heads on cross-linked polyethylene acetabular cups in a wear simulator.
Hermida JC; Bergula A; Chen P; Colwell CW; D'Lima DD
J Bone Joint Surg Am; 2003 Dec; 85(12):2325-31. PubMed ID: 14668501
[TBL] [Abstract][Full Text] [Related]
20. A hip joint simulator study using new and physiologically scratched femoral heads with ultra-high molecular weight polyethylene acetabular cups.
Barbour PS; Stone MH; Fisher J
Proc Inst Mech Eng H; 2000; 214(6):569-76. PubMed ID: 11201404
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]