These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 9141888)

  • 21. Metal release from total hip articulations in vitro: substantial from CoCr/CoCr, negligible from CoCr/PE and alumina/PE.
    Saikko V; Nevalainen J; Revitzer H; Ylinen P
    Acta Orthop Scand; 1998 Oct; 69(5):449-54. PubMed ID: 9855223
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study.
    Kim YH
    J Bone Joint Surg Am; 2005 Aug; 87(8):1769-76. PubMed ID: 16085617
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups.
    Wroblewski BM; Siney PD; Dowson D; Collins SN
    J Bone Joint Surg Br; 1996 Mar; 78(2):280-5. PubMed ID: 8666642
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Wear-testing of a temporomandibular joint prosthesis: UHMWPE and PTFE against a metal ball, in water and in serum.
    Van Loon JP; Verkerke GJ; de Bont LG; Liem RS
    Biomaterials; 1999 Aug; 20(16):1471-8. PubMed ID: 10458560
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Wear of the polyethylene acetabular cup. Metallic and ceramic heads compared in a hip simulator.
    Saikko VO; Paavolainen PO; Slätis P
    Acta Orthop Scand; 1993 Aug; 64(4):391-402. PubMed ID: 8213114
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Wear of conventional and cross-linked ultra-high-molecular-weight polyethylene acetabular cups against polished and roughened CoCr femoral heads in a biaxial hip simulator.
    Saikko V; Calonius O; Keränen J
    J Biomed Mater Res; 2002; 63(6):848-53. PubMed ID: 12418033
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A multi-station hip joint simulator study of the performance of 22 mm diameter zirconia-ultra-high molecular weight polyethylene total replacement hip joints.
    Goldsmith AA; Dowson D
    Proc Inst Mech Eng H; 1999; 213(2):77-90. PubMed ID: 10333682
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Ceramic versus cobalt-chrome femoral components; wear of polyethylene insert in total knee prosthesis.
    Oonishi H; Ueno M; Kim SC; Oonishi H; Iwamoto M; Kyomoto M
    J Arthroplasty; 2009 Apr; 24(3):374-82. PubMed ID: 18524533
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Tribological and surface analysis of 38 mm alumina-as-cast Co-Cr-Mo total hip arthroplasties.
    Williams SR; Wu JJ; Unsworth A; Khan I
    Proc Inst Mech Eng H; 2009 Nov; 223(8):941-54. PubMed ID: 20092092
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.
    Smith SL; Dowson D; Goldsmith AA
    Proc Inst Mech Eng H; 2001; 215(2):161-70. PubMed ID: 11382075
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.
    Roy ME; Whiteside LA; Magill ME; Katerberg BJ
    Clin Orthop Relat Res; 2011 Aug; 469(8):2337-45. PubMed ID: 21312076
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina.
    Tanaka K; Tamura J; Kawanabe K; Shimizu M; Nakamura T
    J Bone Joint Surg Br; 2003 Jul; 85(5):655-60. PubMed ID: 12892185
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Third-body abrasive wear challenge of 32 mm conventional and 44 mm highly crosslinked polyethylene liners in a hip simulator model.
    Sorimachi T; Clarke IC; Williams PA; Gustafson A; Yamamoto K
    Proc Inst Mech Eng H; 2009 Jul; 223(5):607-23. PubMed ID: 19623913
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [In-vivo wear of the slide combinations ceramics-polyethylene as opposed to metal-polyethylene].
    Zichner L; Lindenfeld T
    Orthopade; 1997 Feb; 26(2):129-34. PubMed ID: 9157352
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Hip simulator wear testing according to the newly introduced standard ISO 14242.
    Kaddick C; Wimmer MA
    Proc Inst Mech Eng H; 2001; 215(5):429-42. PubMed ID: 11726043
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Wear of polyethylene acetabular components in total hip arthroplasty. An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations.
    Jasty M; Goetz DD; Bragdon CR; Lee KR; Hanson AE; Elder JR; Harris WH
    J Bone Joint Surg Am; 1997 Mar; 79(3):349-58. PubMed ID: 9070522
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The influence of phospholipid concentration in protein-containing lubricants on the wear of ultra-high molecular weight polyethylene in artificial hip joints.
    Bell J; Tipper JL; Ingham E; Stone MH; Fisher J
    Proc Inst Mech Eng H; 2001; 215(2):259-63. PubMed ID: 11382086
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.
    Garvin KL; White TC; Dusad A; Hartman CW; Martell J
    Clin Orthop Relat Res; 2015 Dec; 473(12):3829-35. PubMed ID: 26122983
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator.
    Ezzet KA; Hermida JC; Colwell CW; D'Lima DD
    Clin Orthop Relat Res; 2004 Nov; (428):120-4. PubMed ID: 15534531
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.