678 related articles for article (PubMed ID: 9148357)
1. [Electron microscopy of the lesions produced in the human dura mater by Quincke beveled and Whitacre needles].
Reina MA; López-García A; de Andrés-Ibáñez JA; Dittmann M; Cascales MR; del Caño MC; Daneri J; Zambrano O
Rev Esp Anestesiol Reanim; 1997 Feb; 44(2):56-61. PubMed ID: 9148357
[TBL] [Abstract][Full Text] [Related]
2. An in vitro study of dural lesions produced by 25-gauge Quincke and Whitacre needles evaluated by scanning electron microscopy.
Reina MA; de Leon-Casasola OA; Lopez A; De Andres J; Martin S; Mora M
Reg Anesth Pain Med; 2000; 25(4):393-402. PubMed ID: 10925937
[TBL] [Abstract][Full Text] [Related]
3. Post dural puncture headache after spinal anaesthesia for caesarean section: a comparison of 25 g Quincke, 27 g Quincke and 27 g Whitacre spinal needles.
Shaikh JM; Memon A; Memon MA; Khan M
J Ayub Med Coll Abbottabad; 2008; 20(3):10-3. PubMed ID: 19610505
[TBL] [Abstract][Full Text] [Related]
4. Comparison of Sprotte and Quincke needles with respect to post dural puncture headache and backache.
Tarkkila PJ; Heine H; Tervo RR
Reg Anesth; 1992; 17(5):283-7. PubMed ID: 1419942
[TBL] [Abstract][Full Text] [Related]
5. [Experience with G27 Whitacre needle in in-patient and out-patient settings--incidence of post dural puncture headaches and other side effects].
Jost U; Hirschauer M; Weinig E; Dörsing C; Jahr C
Anasthesiol Intensivmed Notfallmed Schmerzther; 2000 Jun; 35(6):381-7. PubMed ID: 10900496
[TBL] [Abstract][Full Text] [Related]
6. [The relief of postspinal headache using the Whitacre cannula. Experimental studies].
Kreuscher H; Sandmann G
Reg Anaesth; 1989 May; 12(3):43-5. PubMed ID: 2772271
[TBL] [Abstract][Full Text] [Related]
7. Dura-arachnoid lesions produced by 22 gauge Quincke spinal needles during a lumbar puncture.
Reina MA; López A; Badorrey V; De Andrés JA; Martín S
J Neurol Neurosurg Psychiatry; 2004 Jun; 75(6):893-7. PubMed ID: 15146008
[TBL] [Abstract][Full Text] [Related]
8. Spinal needle determinants of rate of transdural fluid leak.
Ready LB; Cuplin S; Haschke RH; Nessly M
Anesth Analg; 1989 Oct; 69(4):457-60. PubMed ID: 2782645
[TBL] [Abstract][Full Text] [Related]
9. An anatomic study of the effects of dural puncture with different spinal needles.
Celleno D; Capogna G; Costantino P; Catalano P
Reg Anesth; 1993; 18(4):218-21. PubMed ID: 8398954
[TBL] [Abstract][Full Text] [Related]
10. Comparison of 27-gauge (0.41-mm) Whitacre and Quincke spinal needles with respect to post-dural puncture headache and non-dural puncture headache.
Santanen U; Rautoma P; Luurila H; Erkola O; Pere P
Acta Anaesthesiol Scand; 2004 Apr; 48(4):474-9. PubMed ID: 15025611
[TBL] [Abstract][Full Text] [Related]
11. [Subdural intra-arachnoid spread of local anesthetics. A complication of spinal anesthesia].
Möllmann M; Holst D; Enk D; Lübbesmeyer H; Deitmer T; Lawin P
Anaesthesist; 1992 Nov; 41(11):685-8. PubMed ID: 1463156
[TBL] [Abstract][Full Text] [Related]
12. The effect of spinal needle design, size, and penetration angle on dural puncture cerebral spinal fluid loss.
O'Connor G; Gingrich R; Moffat M
AANA J; 2007 Apr; 75(2):111-6. PubMed ID: 17471881
[TBL] [Abstract][Full Text] [Related]
13. An in vitro comparison of fluid leakage after dural puncture with Atraucan, Sprotte, Whitacre, and Quincke needles.
Morrison LM; McCrae AF; Foo I; Scott DB; Wildsmith JA
Reg Anesth; 1996; 21(2):139-43. PubMed ID: 8829406
[TBL] [Abstract][Full Text] [Related]
14. [Development of incidence of post-dural puncture headache in patients undergoing caesarean section in spinal anaesthesia at the Department of Obstetrics and Gynecology in Olomouc during 2003-2004].
L'ubuský M; Berta E; Procházka M; Marek O; Kudela M
Cas Lek Cesk; 2006; 145(3):204-8. PubMed ID: 16634479
[TBL] [Abstract][Full Text] [Related]
15. [The effect of needle type and immobilization on postspinal headache].
Hafer J; Rupp D; Wollbrück M; Engel J; Hempelmann G
Anaesthesist; 1997 Oct; 46(10):860-6. PubMed ID: 9424969
[TBL] [Abstract][Full Text] [Related]
16. [Possibility of cauda equina nerve root damage from lumbar punctures performed with 25-gauge Quincke and Whitacre needles].
Reina MA; López A; Villanueva MC; De Andrés JA; Martín S
Rev Esp Anestesiol Reanim; 2005 May; 52(5):267-75. PubMed ID: 15968905
[TBL] [Abstract][Full Text] [Related]
17. Dural tissue trauma and cerebrospinal fluid leak after epidural needle puncture: effect of needle design, angle, and bevel orientation.
Angle PJ; Kronberg JE; Thompson DE; Ackerley C; Szalai JP; Duffin J; Faure P
Anesthesiology; 2003 Dec; 99(6):1376-82. PubMed ID: 14639152
[TBL] [Abstract][Full Text] [Related]
18. Electron Microscopy of Dural and Arachnoid Disruptions After Subarachnoid Block.
Reina MA; Puigdellívol-Sánchez A; Gatt SP; De Andrés J; Prats-Galino A; van Zundert A
Reg Anesth Pain Med; 2017; 42(6):709-718. PubMed ID: 28991062
[TBL] [Abstract][Full Text] [Related]
19. Comparison of post-dural puncture headache and low back pain between 23 and 25 gauge Quincke spinal needles in patients over 60 years: randomized, double-blind controlled trial.
Kim M; Yoon H
Int J Nurs Stud; 2011 Nov; 48(11):1315-22. PubMed ID: 21561619
[TBL] [Abstract][Full Text] [Related]
20. [Comparison of two 27-G-caliber needles for spinal anesthesia. Study of 1,555 patients].
de Diego Fernández R; Tisner Madrid ML; Cabrerizo Torrente P; Sanjoaquín Mur T
Rev Esp Anestesiol Reanim; 2003 Apr; 50(4):182-7. PubMed ID: 12825306
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]