These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 9157263)

  • 21. In-phantom dosimetry and spectrometry of photoneutrons from an 18 MV linear accelerator.
    d'Errico F; Nath R; Tana L; Curzio G; Alberts WG
    Med Phys; 1998 Sep; 25(9):1717-24. PubMed ID: 9775378
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Dose measurements compared with Monte Carlo simulations of narrow 6 MV multileaf collimator shaped photon beams.
    De Vlamynck K; Palmans H; Verhaegen F; De Wagter C; De Neve W; Thierens H
    Med Phys; 1999 Sep; 26(9):1874-82. PubMed ID: 10505876
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Off-axis output factors for 6MV and 18MV photons.
    Butler AP; Turner JR
    Australas Phys Eng Sci Med; 1997 Sep; 20(3):177-82. PubMed ID: 9409018
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Measurement of the 9Be(p,n) thick target spectrum for use in accelerator-based boron neutron capture therapy.
    Howard WB; Yanch JC; Grimes SM; Massey TN; al-Quraishi SI; Jacobs DK; Brient CE
    Med Phys; 1996 Jul; 23(7):1233-5. PubMed ID: 8839418
    [No Abstract]   [Full Text] [Related]  

  • 25. An automated procedure for the quality assurance of electron beam output and energy.
    Woo MK; Videla NG
    Med Phys; 2004 May; 31(5):972-4. PubMed ID: 15191280
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Long term variation in beam symmetry as a function of gantry angle for a computer-controlled linear accelerator.
    Loyd MD; Lane RG; Laxton J; Chow CH; Rosen II
    Med Phys; 1989; 16(4):614-7. PubMed ID: 2505030
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Total skin electron therapy at two energies on a linear accelerator.
    Turner JR; Hugtenburg RP; Wynne CJ
    Australas Phys Eng Sci Med; 1995 Dec; 18(4):208-20. PubMed ID: 8867391
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reference dosimetry in clinical high-energy photon beams: comparison of the AAPM TG-51 and AAPM TG-21 dosimetry protocols.
    Saiful Huq M; Andreo P
    Med Phys; 2001 Jan; 28(1):46-54. PubMed ID: 11213922
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Shaping of photon beams from electron linear accelerators in radiation therapy.
    Izewska J
    Med Phys; 1993; 20(1):171-7. PubMed ID: 8455496
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Survey of 5 mm small-field output factor measurements in Australia.
    Oliver CP; Butler DJ; Takau V; Williams I
    J Appl Clin Med Phys; 2018 Mar; 19(2):329-337. PubMed ID: 29368796
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Levels of leakage radiation from electron collimators of a linear accelerator.
    Das KR; Cramb JA; Millar RM; Kenny MB; Patterson WR; Ackerly TL; Perkins AE; Chongkitivitya K
    Med Phys; 1990; 17(6):1058-63. PubMed ID: 2126336
    [TBL] [Abstract][Full Text] [Related]  

  • 32. An operational issue of absorbed dose versus dose equivalent in TG-45.
    Christensen R
    Med Phys; 1994 Dec; 21(12):1979, 1981. PubMed ID: 7700206
    [No Abstract]   [Full Text] [Related]  

  • 33. Addendum to the code of practice for electron beam dosimetry in radiotherapy (1985): interim additional recommendations. Working Party of the IPSM.
    Phys Med Biol; 1992 Jul; 37(7):1477-83. PubMed ID: 1631193
    [No Abstract]   [Full Text] [Related]  

  • 34. Determination of electron beam output factors for a 20-MeV linear accelerator.
    Mills MD; Hogstrom KR; Fields RS
    Med Phys; 1985; 12(4):473-6. PubMed ID: 3929052
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Influence of electron contamination on in vivo surface dosimetry for high-energy photon beams.
    Sjögren R; Karlsson M
    Med Phys; 1998 Jun; 25(6):916-21. PubMed ID: 9650182
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry.
    Baldock C; Burford RP; Billingham N; Wagner GS; Patval S; Badawi RD; Keevil SF
    Phys Med Biol; 1998 Mar; 43(3):695-702. PubMed ID: 9533146
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A protocol for the determination of absorbed dose from high-energy photon and electron beams.
    Med Phys; 1983; 10(6):741-71. PubMed ID: 6419029
    [No Abstract]   [Full Text] [Related]  

  • 38. Extrafocal radiation: a unified approach to the prediction of beam penumbra and output factors for megavoltage x-ray beams.
    Sharpe MB; Jaffray DA; Battista JJ; Munro P
    Med Phys; 1995 Dec; 22(12):2065-74. PubMed ID: 8746712
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Monte Carlo calculation of output factors for circular, rectangular, and square fields of electron accelerators (6-20 MeV).
    Verhaegen F; Mubata C; Pettingell J; Bidmead AM; Rosenberg I; Mockridge D; Nahum AE
    Med Phys; 2001 Jun; 28(6):938-49. PubMed ID: 11439490
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An equivalent square field formula for determining head scatter factors of rectangular fields.
    Kim S; Zhu TC; Palta JR
    Med Phys; 1997 Nov; 24(11):1770-4. PubMed ID: 9394284
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.