These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

122 related articles for article (PubMed ID: 9157350)

  • 21. [Bone reaction to contact with a granulated titanium surface. Apropos of 101 total hip prostheses with six years follow-up].
    Nègre J; Henry F
    Rev Chir Orthop Reparatrice Appar Mot; 1995; 81(2):106-13. PubMed ID: 7569185
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Non-linear three-dimensional finite element analysis of a cementless hip endoprosthesis.
    Tensi HM; Gese H; Ascherl R
    Proc Inst Mech Eng H; 1989; 203(4):215-22. PubMed ID: 2701959
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of hydroxyapatite coating on the radio-clinical results of a grit-blasted titanium alloy femoral taper. A case-control study of 198 cementless primary total hip arthroplasty with the Alloclassic™ system.
    Delaunay C
    Orthop Traumatol Surg Res; 2014 Nov; 100(7):739-44. PubMed ID: 25261173
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Cementless total hip arthroplasty.
    Morscher EW
    Clin Orthop Relat Res; 1983 Dec; (181):76-91. PubMed ID: 6357588
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Cementless hip prosthesis: goals, problems, evaluation methods].
    Lemaire R
    Acta Orthop Belg; 1993; 59 Suppl 1():88-94. PubMed ID: 8116448
    [No Abstract]   [Full Text] [Related]  

  • 26. [Noncemented total hip arthroplasty: influence of extramedullary parameters on initial implant stability and on bone-implant interface stresses].
    Ramaniraka NA; Rakotomanana LR; Rubin PJ; Leyvraz P
    Rev Chir Orthop Reparatrice Appar Mot; 2000 Oct; 86(6):590-7. PubMed ID: 11060433
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Special problems of cementless fixation of total hip-joint endoprostheses with reference to the PM type.
    Refior HJ; Parhofer R; Ungethüm M; Blömer W
    Arch Orthop Trauma Surg (1978); 1988; 107(3):158-71. PubMed ID: 3382335
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A cementless titanium hip endoprosthesis system based on press-fit fixation: basic research and clinical results.
    Zweymüller K
    Instr Course Lect; 1986; 35():203-25. PubMed ID: 3819408
    [No Abstract]   [Full Text] [Related]  

  • 29. The self-locking Balgrist hip socket for cementless fixation: biomechanical principles and clinical results.
    Schreiber A; Jacob HA; Hauser R; Kern S
    Keio J Med; 1993 Jun; 42(2):53-9. PubMed ID: 8341032
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Cementless implant fixation--toward improved reliability.
    Pilliar RM
    Orthop Clin North Am; 2005 Jan; 36(1):113-9. PubMed ID: 15542130
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Clinical and radiographic experience with a hydroxyapatite-coated titanium plasma-sprayed porous implant.
    Vaughn BK; Lombardi AV; Mallory TH
    Semin Arthroplasty; 1991 Oct; 2(4):309-16. PubMed ID: 10149619
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Comparison of different hip prosthesis shapes considering micro-level bone remodeling and stress-shielding criteria using three-dimensional design space topology optimization.
    Boyle C; Kim IY
    J Biomech; 2011 Jun; 44(9):1722-8. PubMed ID: 21497816
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Osseointegration of total hip arthroplasties: studies in humans and animals.
    Song Y; Beaupre G; Goodman SB
    J Long Term Eff Med Implants; 1999; 9(1-2):77-112. PubMed ID: 10537590
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Effects of porous coating, with and without collar support, on early relative motion for a cementless hip prosthesis.
    Keaveny TM; Bartel DL
    J Biomech; 1993 Dec; 26(12):1355-68. PubMed ID: 8308041
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Modified metaphyseal-loading anterolaterally flared anatomic femoral stem: five- to nine-year prospective follow-up evaluation and results of three-dimensional finite element analysis.
    Kokubo Y; Uchida K; Oki H; Negoro K; Nagamune K; Kawaguchi S; Takeno K; Yayama T; Nakajima H; Sugita D; Yoshida A; Baba H
    Artif Organs; 2013 Feb; 37(2):175-82. PubMed ID: 23009086
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Technology of cementless hip endoprosthetics].
    Ungethüm M; Blömer W
    Orthopade; 1987 Jun; 16(3):170-84. PubMed ID: 3627790
    [TBL] [Abstract][Full Text] [Related]  

  • 37. [Experience with the cementless hip prosthesis, with special reference to the implantation of prosthesis stems].
    Krakovits G; Sass L; Farkas L
    Magy Traumatol Orthop Helyreallito Seb; 1989; 32(2):131-8. PubMed ID: 2570888
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Flocking hip joint endoprosthesis].
    Sherepo KM
    Med Tekh; 1997; (4):26-32. PubMed ID: 9379860
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Computer and experimental analyses of the stress state in the cement hip joint endoprosthesis body.
    Tabaković S; Grujić J; Zeljković M; Blagojević Z; Radojević B; Popović Z; Zivković A; Stevanović V
    Vojnosanit Pregl; 2014 Nov; 71(11):1034-9. PubMed ID: 25536806
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The contributions and limitations of hydroxyapatite coatings to implant fixation: A histomorphometric study of load bearing implants in dogs.
    Munting E
    Int Orthop; 1996; 20(1):1-6. PubMed ID: 8881881
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.