These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 9158364)
1. Tracheal mucus velocity remains normal in healthy sheep intubated with a new endotracheal tube with a novel laryngeal seal. Trawöger R; Kolobow T; Cereda M; Sparacino ME Anesthesiology; 1997 May; 86(5):1140-4. PubMed ID: 9158364 [TBL] [Abstract][Full Text] [Related]
2. New ultrathin-walled endotracheal tube with a novel laryngeal seal design. Long-term evaluation in sheep. Reali-Forster C; Kolobow T; Giacomini M; Hayashi T; Horiba K; Ferrans VJ Anesthesiology; 1996 Jan; 84(1):162-72; discussion 27A. PubMed ID: 8572330 [TBL] [Abstract][Full Text] [Related]
4. Endotracheal tubes for critically ill patients: an in vivo analysis of associated tracheal injury, mucociliary clearance, and sealing efficacy. Li Bassi G; Luque N; Martí JD; Aguilera Xiol E; Di Pasquale M; Giunta V; Comaru T; Rigol M; Terraneo S; De Rosa F; Rinaudo M; Crisafulli E; Peralta Lepe RC; Agusti C; Lucena C; Ferrer M; Fernández L; Torres A Chest; 2015 May; 147(5):1327-1335. PubMed ID: 25500677 [TBL] [Abstract][Full Text] [Related]
5. Following tracheal intubation, mucus flow is reversed in the semirecumbent position: possible role in the pathogenesis of ventilator-associated pneumonia. Li Bassi G; Zanella A; Cressoni M; Stylianou M; Kolobow T Crit Care Med; 2008 Feb; 36(2):518-25. PubMed ID: 18176317 [TBL] [Abstract][Full Text] [Related]
6. A 72-hour study to test the efficacy and safety of the "Mucus Slurper" in mechanically ventilated sheep. Li Bassi G; Curto F; Zanella A; Stylianou M; Kolobow T Crit Care Med; 2007 Mar; 35(3):906-11. PubMed ID: 17255853 [TBL] [Abstract][Full Text] [Related]
7. Performance of the PneuX System: A Bench Study Comparison With 4 Other Endotracheal Tube Cuffs. Chenelle CT; Itagaki T; Fisher DF; Berra L; Kacmarek RM Respir Care; 2017 Jan; 62(1):102-112. PubMed ID: 27879379 [TBL] [Abstract][Full Text] [Related]
8. Endotracheal Tube Seal and Suction Performance in a Novel Biorealistic Tracheal Model. Rozycki SK; Dixon FP; Yopp MA; Maxvold NJ; Rubin BK Respir Care; 2015 Aug; 60(8):1113-9. PubMed ID: 25944945 [TBL] [Abstract][Full Text] [Related]
9. Design and development of ultrathin-walled, nonkinking endotracheal tubes of a new "no-pressure" laryngeal seal design. A preliminary report. Kolobow T; Tsuno K; Rossi N; Aprigliano M Anesthesiology; 1994 Oct; 81(4):1061-7. PubMed ID: 7943817 [TBL] [Abstract][Full Text] [Related]
10. Endotracheal tubes and fluid aspiration: an in vitro evaluation of new cuff technologies. Mariyaselvam MZ; Marsh LL; Bamford S; Smith A; Wise MP; Williams DW BMC Anesthesiol; 2017 Mar; 17(1):36. PubMed ID: 28257624 [TBL] [Abstract][Full Text] [Related]
11. Endotracheal tubes coated with antiseptics decrease bacterial colonization of the ventilator circuits, lungs, and endotracheal tube. Berra L; De Marchi L; Yu ZX; Laquerriere P; Baccarelli A; Kolobow T Anesthesiology; 2004 Jun; 100(6):1446-56. PubMed ID: 15166564 [TBL] [Abstract][Full Text] [Related]
12. Endotracheal tube and laryngeal mask airway cuff pressures can exceed critical values during ascent to higher altitude. Miyashiro RM; Yamamoto LG Pediatr Emerg Care; 2011 May; 27(5):367-70. PubMed ID: 21494168 [TBL] [Abstract][Full Text] [Related]
13. Antibacterial-coated tracheal tubes cleaned with the Mucus Shaver : a novel method to retain long-term bactericidal activity of coated tracheal tubes. Berra L; Curto F; Li Bassi G; Laquerriere P; Baccarelli A; Kolobow T Intensive Care Med; 2006 Jun; 32(6):888-93. PubMed ID: 16601964 [TBL] [Abstract][Full Text] [Related]
14. Clearance of mucus from endotracheal tubes during intratracheal pulmonary ventilation. Trawöger R; Kolobow T; Cereda M; Giacomini M; Usuki J; Horiba K; Ferrans VJ Anesthesiology; 1997 Jun; 86(6):1367-74. PubMed ID: 9197307 [TBL] [Abstract][Full Text] [Related]
15. The Mucus Slurper: A novel tracheal tube that requires no tracheal tube suctioning. A preliminary report. Kolobow T; Li Bassi G; Curto F; Zanella A Intensive Care Med; 2006 Sep; 32(9):1414-8. PubMed ID: 16826389 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of continuous aspiration of subglottic secretion in an in vivo study. Berra L; De Marchi L; Panigada M; Yu ZX; Baccarelli A; Kolobow T Crit Care Med; 2004 Oct; 32(10):2071-8. PubMed ID: 15483416 [TBL] [Abstract][Full Text] [Related]
17. Comparative effects of salmeterol, albuterol, and ipratropium on normal and impaired mucociliary function in sheep. Sabater JR; Lee TA; Abraham WM Chest; 2005 Nov; 128(5):3743-9. PubMed ID: 16304342 [TBL] [Abstract][Full Text] [Related]
18. Endothelin-1 depresses tracheal mucus velocity in ovine airways via ET-A receptors. Sabater JR; Otero R; Abraham WM; Wanner A; O'Riordan TG Am J Respir Crit Care Med; 1996 Aug; 154(2 Pt 1):341-5. PubMed ID: 8756804 [TBL] [Abstract][Full Text] [Related]
19. Impairment of tracheal mucociliary clearance but not ciliary beat frequency by a combination of low level ozone and sulfur dioxide in sheep. Abraham WM; Sielczak MW; Delehunt JC; Marchette B; Wanner A Eur J Respir Dis; 1986 Feb; 68(2):114-20. PubMed ID: 3699114 [TBL] [Abstract][Full Text] [Related]
20. Effect of cuffed endotracheal tubes on tracheal mucous velocity. Sackner MA; Hirsch J; Epstein S Chest; 1975 Dec; 68(6):774-7. PubMed ID: 1192854 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]