These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. A prospective randomized comparison in humans of biphasic waveform 60-microF and 120-microF capacitance pulses using a unipolar defibrillation system. Bardy GH; Poole JE; Kudenchuk PJ; Dolack GL; Mehra R; DeGroot P; Raitt MH; Jones GK; Johnson G Circulation; 1995 Jan; 91(1):91-5. PubMed ID: 7805224 [TBL] [Abstract][Full Text] [Related]
5. Effects of polarity on defibrillation thresholds using a biphasic waveform in a hot can electrode system. Yamanouchi Y; Mowrey KA; Nadzam GR; Hills DG; Kroll MW; Brewer JE; Donohoo AM; Wilkoff BL; Tchou PJ Pacing Clin Electrophysiol; 1997 Dec; 20(12 Pt 1):2911-6. PubMed ID: 9455750 [TBL] [Abstract][Full Text] [Related]
10. Biphasic waveform defibrillation using a three-electrode transvenous lead system in humans. Marks ML; Johnson G; Hofer BO; Bardy GH J Cardiovasc Electrophysiol; 1994 Feb; 5(2):103-8. PubMed ID: 8186880 [TBL] [Abstract][Full Text] [Related]
11. Internal defibrillation with smaller capacitors: a prospective randomized cross-over comparison of defibrillation efficacy obtained with 90-microF and 125-microF capacitors in humans. Block M; Hammel D; Böcker D; Borggrefe M; Seifert T; Fastenrath C; Scheld HH; Breithardt G J Cardiovasc Electrophysiol; 1995 May; 6(5):333-42. PubMed ID: 7551301 [TBL] [Abstract][Full Text] [Related]
12. Truncated biphasic pulses for transthoracic defibrillation. Bardy GH; Gliner BE; Kudenchuk PJ; Poole JE; Dolack GL; Jones GK; Anderson J; Troutman C; Johnson G Circulation; 1995 Mar; 91(6):1768-74. PubMed ID: 7882486 [TBL] [Abstract][Full Text] [Related]
13. Effect of shock waveform on relationship between upper limit of vulnerability and defibrillation threshold. Swerdlow CD; Kass RM; O'Connor ME; Chen PS J Cardiovasc Electrophysiol; 1998 Apr; 9(4):339-49. PubMed ID: 9581950 [TBL] [Abstract][Full Text] [Related]
14. Optimizing defibrillation through improved waveforms. Block M; Breithardt G Pacing Clin Electrophysiol; 1995 Mar; 18(3 Pt 2):526-38. PubMed ID: 7777417 [TBL] [Abstract][Full Text] [Related]
15. Ventricular defibrillation with triphasic waveforms. Huang J; KenKnight BH; Rollins DL; Smith WM; Ideker RE Circulation; 2000 Mar; 101(11):1324-8. PubMed ID: 10725294 [TBL] [Abstract][Full Text] [Related]
16. Effect of electrode polarity on internal defibrillation with monophasic and biphasic waveforms using an endocardial lead system. Huang J; KenKnight BH; Walcott GP; Walker RG; Smith WM; Ideker RE J Cardiovasc Electrophysiol; 1997 Feb; 8(2):161-71. PubMed ID: 9048247 [TBL] [Abstract][Full Text] [Related]
17. Effects of respiration phase on ventricular defibrillation threshold in a hot can electrode system. Yamanouchi Y; Mowrey KA; Kroll MW; Brewer JE; Donohoo AM; Niebauer MJ; Wilkoff BL; Tchou PJ Pacing Clin Electrophysiol; 1998 Jun; 21(6):1216-24. PubMed ID: 9633063 [TBL] [Abstract][Full Text] [Related]
18. Effect of changing capacitors between phases of a biphasic defibrillation shock. Walcott GP; Rollins DL; Smith WM; Ideker RE Pacing Clin Electrophysiol; 1996 Jun; 19(6):945-54. PubMed ID: 8774825 [TBL] [Abstract][Full Text] [Related]
19. Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system. Poole JE; Bardy GH; Kudenchuk PJ; Dolack GL; Raitt MH; Mehra R; Johnson G Pacing Clin Electrophysiol; 1995 Jul; 18(7):1369-73. PubMed ID: 7567589 [TBL] [Abstract][Full Text] [Related]
20. Internal cardioversion of atrial fibrillation in sheep. Cooper RA; Alferness CA; Smith WM; Ideker RE Circulation; 1993 May; 87(5):1673-86. PubMed ID: 8491023 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]