BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 9164111)

  • 21. Initial clinical experience with a new heparin-coated chronic hemodialysis catheter.
    Mojibian H; Spector M; Ni N; Eliseo D; Pollak J; Tal M
    Hemodial Int; 2009 Jul; 13(3):329-34. PubMed ID: 19473278
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Material thrombogenicity in central venous catheterization. I. A comparison between uncoated and heparin-coated, long antebrachial, polyethylene catheters.
    Bennegård K; Curelaru I; Gustavsson B; Linder LE; Zachrisson BF
    Acta Anaesthesiol Scand; 1982 Apr; 26(2):112-20. PubMed ID: 7048839
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [A clinical study of thrombus formation associated with central venous catheterization].
    Yagi K; Kawakami M; Sugimoto T
    Nihon Geka Gakkai Zasshi; 1988 Dec; 89(12):1943-9. PubMed ID: 3231204
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Thrombus formation on the balloon of heparin-bonded pulmonary artery catheters: an ultrastructural scanning electron microscope study.
    Hofbauer R; Moser D; Kaye AD; Dielacher C; Hornykewycz S; Handler S; Speiser W; Kapiotis S; Frass M
    Crit Care Med; 2000 Mar; 28(3):727-35. PubMed ID: 10752822
    [TBL] [Abstract][Full Text] [Related]  

  • 25. A comparative study of several polymers for use as intravenous catheters.
    Sawyer PN; Ramsey W; Stanczewski B; Turner R; Liebig W; Kammlott GW; Braun B
    Med Instrum; 1977; 11(4):221-30. PubMed ID: 895597
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Catheter coatings, blood flow, and biocompatibility.
    Eberhart RC; Clagett CP
    Semin Hematol; 1991 Oct; 28(4 Suppl 7):42-8; discussion 66-8. PubMed ID: 1822610
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Reduced thrombus formation with silicone elastomere (silastic) umbilical artery catheters.
    Boros SJ; Thompson TR; Reynolds JW; Jarvis CW; Williams HJ
    Pediatrics; 1975 Dec; 56(6):981-6. PubMed ID: 1196766
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The impact of catheter-restricted filling with cefotaxime and heparin on the lifespan of temporary hemodialysis catheters: a case controlled study.
    Saxena AK; Panhotra BR
    J Nephrol; 2005; 18(6):755-63. PubMed ID: 16358235
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Thrombogenicity of tips of umbilical catheters.
    Hecker JF
    Pediatrics; 1981 Apr; 67(4):467-71. PubMed ID: 7254968
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Electron microscopic study on the surface of long-term indwelling silver-protein-coated urethral catheters (Urotopic Ag Protein)].
    Konishi T; Tomoyoshi T; Johnin K
    Hinyokika Kiyo; 1997 Jan; 43(1):19-23. PubMed ID: 9046416
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Usefulness of subcutaneous implantable port with new one-way valve].
    Sawamura A; Aogi K; Yoshimoto A; Yamaguchi Y; Miyahara E; Kawami H; Hihara J; Noma K; Toge T
    Gan To Kagaku Ryoho; 1996 Sep; 23(11):1555-7. PubMed ID: 8854803
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A scanning electron microscopic study on thrombogenicity of intraarterial catheters for chemotherapeutic treatment in head and neck cancer.
    Moser D; Rasse M; Schopper C; Lagogiannis G; Frass M; Ewers R; Kaye AD; Hofbauer R
    Head Neck; 2002 Jun; 24(6):566-74. PubMed ID: 12112554
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Chronic performance of polyurethane catheters covalently coated with ATH complex: a rabbit jugular vein model.
    Klement P; Du YJ; Berry LR; Tressel P; Chan AK
    Biomaterials; 2006 Oct; 27(29):5107-17. PubMed ID: 16781768
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Experience in the use of Kyosera Injection Port as a kind of implantable reservoir (the second report)].
    Takano S; Oishi T; Watanabe Y; Higaki T; Moriguchi M; Oishi H; Seki N; Fujii M; Tanaka T
    Gan To Kagaku Ryoho; 1990 Apr; 17(4 Pt 1):675-9. PubMed ID: 2321986
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [A new non-surgically implantable catheter port system for locoregional chemotherapy of advanced bladder cancer].
    Strecker EP; Michaelis W; Claus T; Tsikuras P
    Rofo; 1990 Sep; 153(3):260-5. PubMed ID: 2171057
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Clot formation in angiographic catheters--an in vitro comparative study. Effects of heparin and protein coating of the catheter.
    Raininko R; Söder H
    Acta Radiol; 1993 Jan; 34(1):78-82. PubMed ID: 8427754
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A comparative multicentre study on the incidence of catheter-associated urinary tract infection between nitrofurazone-coated and silicone catheters.
    Lee SJ; Kim SW; Cho YH; Shin WS; Lee SE; Kim CS; Hong SJ; Chung BH; Kim JJ; Yoon MS
    Int J Antimicrob Agents; 2004 Sep; 24 Suppl 1():S65-9. PubMed ID: 15364311
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Testing an implantable intraspinal drug delivery device in the ewe.
    Coombs DW; Colburn RW; DeLeo JA; Twitchell BB
    Reg Anesth; 1993; 18(4):230-7. PubMed ID: 8398957
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Randomized trial of prevention of catheter-related bloodstream infection by continuous infusion of low-dose unfractionated heparin in patients with hematologic and oncologic disease.
    Abdelkefi A; Torjman L; Ladeb S; Othman TB; Achour W; Lakhal A; Hsairi M; Kammoun L; Hassen AB; Abdeladhim AB
    J Clin Oncol; 2005 Nov; 23(31):7864-70. PubMed ID: 16258088
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Surface-treated catheters--a review.
    Dwyer A
    Semin Dial; 2008; 21(6):542-6. PubMed ID: 19000120
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 4.