These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
373 related articles for article (PubMed ID: 9167924)
21. Biomechanical Analysis of a Novel Syndesmotic Plate Compared With Traditional Screw and Suture Button Fixation. Weng Q; Lin C; Liu Y; Dai G; Lutchooman V; Hong J J Foot Ankle Surg; 2020; 59(3):522-528. PubMed ID: 31864842 [TBL] [Abstract][Full Text] [Related]
22. [Biomechanical study on repairing distal tibiofibular syndesmosis injuries with artificial ligaments]. Wu Z; Wang B; Cao Y; Zhao Y; Wang Y Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Oct; 28(10):1217-20. PubMed ID: 25591295 [TBL] [Abstract][Full Text] [Related]
23. Strength of Syndesmosis Fixation: Two TightRope versus One TightRope with Plate-and-Screw Construct. Tsai J; Pivec R; Jauregui JJ; Hayes WT; McLeold M; Naziri Q; Kapadia BH; Saha S; Uribe JA J Long Term Eff Med Implants; 2016; 26(2):161-165. PubMed ID: 28094740 [TBL] [Abstract][Full Text] [Related]
24. The Fate of the Fixed Syndesmosis Over Time. Gennis E; Koenig S; Rodericks D; Otlans P; Tornetta P Foot Ankle Int; 2015 Oct; 36(10):1202-8. PubMed ID: 26041545 [TBL] [Abstract][Full Text] [Related]
25. Screw fixation of the syndesmosis: a cadaver model comparing stainless steel and titanium screws and three and four cortical fixation. Beumer A; Campo MM; Niesing R; Day J; Kleinrensink GJ; Swierstra BA Injury; 2005 Jan; 36(1):60-4. PubMed ID: 15589915 [TBL] [Abstract][Full Text] [Related]
26. Biomechanical effects of internal fixation of the distal tibiofibular syndesmotic joint: comparison of two fixation techniques. Peter RE; Harrington RM; Henley MB; Tencer AF J Orthop Trauma; 1994; 8(3):215-9. PubMed ID: 8027890 [TBL] [Abstract][Full Text] [Related]
27. Technical aspects of the syndesmotic screw and their effect on functional outcome following acute distal tibiofibular syndesmosis injury. Schepers T; van der Linden H; van Lieshout EM; Niesten DD; van der Elst M Injury; 2014 Apr; 45(4):775-9. PubMed ID: 24139172 [TBL] [Abstract][Full Text] [Related]
28. Syndesmosis fixation using dual 3.5 mm and 4.5 mm screws with tricortical and quadricortical purchase: a biomechanical study. Markolf KL; Jackson SR; McAllister DR Foot Ankle Int; 2013 May; 34(5):734-9. PubMed ID: 23405026 [TBL] [Abstract][Full Text] [Related]
29. Novel anatomical reconstruction of distal tibiofibular ligaments restores syndesmotic biomechanics. Che J; Li C; Gao Z; Qi W; Ji B; Liu Y; Liow MHL Knee Surg Sports Traumatol Arthrosc; 2017 Jun; 25(6):1866-1872. PubMed ID: 28321479 [TBL] [Abstract][Full Text] [Related]
30. The management of acute distal tibio-fibular syndesmotic injuries: results of a nationwide survey. Schepers T; van Zuuren WJ; van den Bekerom MP; Vogels LM; van Lieshout EM Injury; 2012 Oct; 43(10):1718-23. PubMed ID: 22795845 [TBL] [Abstract][Full Text] [Related]
31. Alterations in tibiotalar joint reaction force following syndesmotic injury are restored with static syndesmotic fixation. Kelly M; Vasconcellos D; Osman WS; Masqoodi N; Fowler X; Elfar JC; Olles MW; Flemister AS; Ketz JP; Oh I Clin Biomech (Bristol); 2019 Oct; 69():156-163. PubMed ID: 31352256 [TBL] [Abstract][Full Text] [Related]
32. Suture-button fixation and anterior inferior tibiofibular ligament augmentation with suture-tape for syndesmosis injury: A biomechanical cadaveric study. Shoji H; Teramoto A; Suzuki D; Okada Y; Sakakibara Y; Matsumura T; Suzuki T; Watanabe K; Yamashita T Clin Biomech (Bristol); 2018 Dec; 60():121-126. PubMed ID: 30342380 [TBL] [Abstract][Full Text] [Related]
33. Comparison of Open Anterior Syndesmotic Repair Augmented With Suture-Tape and Trans-syndesmotic Screw Fixation: A Biomechanical Study. Lee HS; Kim WJ; Young KW; Jeong GM; Yeo ED; Lee YK J Foot Ankle Surg; 2021; 60(2):339-344. PubMed ID: 33431315 [TBL] [Abstract][Full Text] [Related]
34. Effects of ligament sectioning on the kinematics of the distal tibiofibular syndesmosis: a radiostereometric study of 10 cadaveric specimens based on presumed trauma mechanisms with suggestions for treatment. Beumer A; Valstar ER; Garling EH; Niesing R; Ginai AZ; Ranstam J; Swierstra BA Acta Orthop; 2006 Jun; 77(3):531-40. PubMed ID: 16819696 [TBL] [Abstract][Full Text] [Related]
35. Biomechanical comparison of syndesmosis fixation with 3.5- and 4.5-millimeter stainless steel screws. Thompson MC; Gesink DS Foot Ankle Int; 2000 Sep; 21(9):736-41. PubMed ID: 11023220 [TBL] [Abstract][Full Text] [Related]
36. Suture-button versus screw fixation of the syndesmosis: a biomechanical analysis. Klitzman R; Zhao H; Zhang LQ; Strohmeyer G; Vora A Foot Ankle Int; 2010 Jan; 31(1):69-75. PubMed ID: 20067726 [TBL] [Abstract][Full Text] [Related]
37. A 3-D CT Analysis of Screw and Suture-Button Fixation of the Syndesmosis. Schon JM; Williams BT; Venderley MB; Dornan GJ; Backus JD; Turnbull TL; LaPrade RF; Clanton TO Foot Ankle Int; 2017 Feb; 38(2):208-214. PubMed ID: 27733556 [TBL] [Abstract][Full Text] [Related]