These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 9171127)

  • 1. Port site electrosurgical (diathermy) burns during surgical laparoscopy.
    Willson PD; van der Walt JD; Moxon D; Rogers J
    Surg Endosc; 1997 Jun; 11(6):653-4. PubMed ID: 9171127
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monopolar electrosurgery through single-port laparoscopy: a potential hidden hazard for bowel burns.
    Abu-Rafea B; Vilos GA; Al-Obeed O; AlSheikh A; Vilos AG; Al-Mandeel H
    J Minim Invasive Gynecol; 2011; 18(6):734-40. PubMed ID: 21925969
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Surgical complications specific to monopolar electrosurgical energy: engineering changes that have made electrosurgery safer.
    Odell RC
    J Minim Invasive Gynecol; 2013; 20(3):288-98. PubMed ID: 23659749
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Laparoscopic electrosurgical injuries: survey results and their implications.
    Tucker RD
    Surg Laparosc Endosc; 1995 Aug; 5(4):311-7. PubMed ID: 7551285
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Education and engineering solutions for potential problems with laparoscopic monopolar electrosurgery.
    Voyles CR; Tucker RD
    Am J Surg; 1992 Jul; 164(1):57-62. PubMed ID: 1385675
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cause and prevention of electrosurgical injuries in laparoscopy.
    Nduka CC; Super PA; Monson JR; Darzi AW
    J Am Coll Surg; 1994 Aug; 179(2):161-70. PubMed ID: 8044385
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Complications and recommended practices for electrosurgery in laparoscopy.
    Wu MP; Ou CS; Chen SL; Yen EY; Rowbotham R
    Am J Surg; 2000 Jan; 179(1):67-73. PubMed ID: 10737583
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Indirect electrical injuries from capacitive coupling: a rarely mentioned electrosurgical complication in monopolar laparoscopy.
    Liu Q; Sun XB
    Acta Obstet Gynecol Scand; 2013 Feb; 92(2):238-41. PubMed ID: 23193981
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Alternate-site burns from improperly seated electrosurgical pencil active electrodes.
    Health Devices; 2000 Jan; 29(1):24-7. PubMed ID: 10631561
    [No Abstract]   [Full Text] [Related]  

  • 10. Alternate-site burns from improperly seated or damaged electrosurgical pencil active electrodes.
    Health Devices; 2012 Oct; 41(10):334. PubMed ID: 23444680
    [No Abstract]   [Full Text] [Related]  

  • 11. Active electrode monitoring. How to prevent unintentional thermal injury associated with monopolar electrosurgery at laparoscopy.
    Vancaillie TG
    Surg Endosc; 1998 Aug; 12(8):1009-12. PubMed ID: 9685531
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Antenna coupling--a novel mechanism of radiofrequency electrosurgery complication: practical implications.
    Robinson TN; Barnes KS; Govekar HR; Stiegmann GV; Dunn CL; McGreevy FT
    Ann Surg; 2012 Aug; 256(2):213-8. PubMed ID: 22791097
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electrophysical properties of electrosurgery and capacitive induced current.
    Vilos G; Latendresse K; Gan BS
    Am J Surg; 2001 Sep; 182(3):222-5. PubMed ID: 11587681
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intended and stray radiofrequency electrical currents during resectoscopic surgery.
    Vilos GA; McCulloch S; Borg P; Zheng W; Denstedt J
    J Am Assoc Gynecol Laparosc; 2000 Feb; 7(1):55-63. PubMed ID: 10648740
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrosurgical generators and monopolar and bipolar electrosurgery.
    Vilos GA; Rajakumar C
    J Minim Invasive Gynecol; 2013; 20(3):279-87. PubMed ID: 23659748
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Insulation failure in laparoscopic instruments.
    Montero PN; Robinson TN; Weaver JS; Stiegmann GV
    Surg Endosc; 2010 Feb; 24(2):462-5. PubMed ID: 19572175
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Thermal injury due to electrosurgery.
    Tuncel U; Ozgenel GY
    Ulus Travma Acil Cerrahi Derg; 2005 Jan; 11(1):76-7. PubMed ID: 15688274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Unrecognized hazards of surgical electrodes passed through metal suction-irrigation devices.
    Voyles CR; Tucker RD
    Surg Endosc; 1994 Mar; 8(3):185-7. PubMed ID: 8191356
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Single-incision laparoscopic surgery increases the risk of unintentional thermal injury from the monopolar "Bovie" instrument in comparison with traditional laparoscopy.
    Townsend NT; Jones EL; Overbey D; Dunne B; McHenry J; Robinson TN
    Surg Endosc; 2017 Aug; 31(8):3146-3151. PubMed ID: 27864716
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Electrosurgery in otolaryngology-head and neck surgery: principles, advances, and complications.
    Smith TL; Smith JM
    Laryngoscope; 2001 May; 111(5):769-80. PubMed ID: 11359154
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.