BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

284 related articles for article (PubMed ID: 9174228)

  • 1. Thermal balance in term and preterm newborn infants nursed in an incubator equipped with a radiant heat source.
    Sjörs G; Hammarlund K; Sedin G
    Acta Paediatr; 1997 Apr; 86(4):403-9. PubMed ID: 9174228
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Additional double-wall roof in single-wall, closed, convective incubators: Impact on body heat loss from premature infants and optimal adjustment of the incubator air temperature.
    Delanaud S; Decima P; Pelletier A; Libert JP; Stephan-Blanchard E; Bach V; Tourneux P
    Med Eng Phys; 2016 Sep; 38(9):922-8. PubMed ID: 27387899
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Water loss from the skin of term and preterm infants nursed under a radiant heater.
    Kjartansson S; Arsan S; Hammarlund K; Sjörs G; Sedin G
    Pediatr Res; 1995 Feb; 37(2):233-8. PubMed ID: 7731762
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Infant incubators and radiant warmers.
    Bell EF
    Early Hum Dev; 1983 Oct; 8(3-4):351-75. PubMed ID: 6641579
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The heat balance of small babies nursed in incubators and under radiant warmers.
    Wheldon AE; Rutter N
    Early Hum Dev; 1982 Apr; 6(2):131-43. PubMed ID: 7094851
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mannequin-assessed dry-heat exchanges in the incubator-nursed newborn.
    Apedoh A; el Hajajji A; Telliez F; Bouferrache B; Libert JP; Rachid A
    Biomed Instrum Technol; 1999; 33(5):446-54. PubMed ID: 10511915
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A double-walled incubator alters the partition of body heat loss of premature infants.
    Bell EF; Rios GR
    Pediatr Res; 1983 Feb; 17(2):135-40. PubMed ID: 6402753
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cardiovascular changes in preterm infants nursed under radiant warmers.
    Walther FJ; Wu PY; Siassi B
    Pediatrics; 1987 Aug; 80(2):235-9. PubMed ID: 3615094
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Relative efficacy of radiant and convective heat in incubators in producing thermoneutrality for the premature.
    Leblanc MH
    Pediatr Res; 1984 May; 18(5):425-8. PubMed ID: 6728569
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A clinical comparison of radiant warmer and incubator care for preterm infants from birth to 1800 grams.
    Meyer MP; Payton MJ; Salmon A; Hutchinson C; de Klerk A
    Pediatrics; 2001 Aug; 108(2):395-401. PubMed ID: 11483805
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Early skin-to-skin care in extremely preterm infants: thermal balance and care environment.
    Karlsson V; Heinemann AB; Sjörs G; Nykvist KH; Agren J
    J Pediatr; 2012 Sep; 161(3):422-6. PubMed ID: 22497906
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Neutral temperature range in incubators: performance of equipment in current use and new developments.
    Libert JP; Bach V; Farges G
    Crit Rev Biomed Eng; 1997; 25(4-5):287-370. PubMed ID: 9505136
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Optimal thermal management for low birth weight infants nursed under high-powered radiant warmers.
    Malin SW; Baumgart S
    Pediatrics; 1987 Jan; 79(1):47-54. PubMed ID: 3797170
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Continuous measurement of core body temperature in preterm infants.
    Dollberg S; Rimon A; Atherton HD; Hoath SB
    Am J Perinatol; 2000; 17(5):257-64. PubMed ID: 11110344
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiant heat loss versus radiant heat gain in premature neonates under radiant warmers.
    Baumgart S
    Biol Neonate; 1990; 57(1):10-20. PubMed ID: 2302433
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Assessing neonatal heat balance and physiological strain in newborn infants nursed under radiant warmers in intensive care with fentanyl sedation.
    Molgat-Seon Y; Daboval T; Chou S; Jay O
    Eur J Appl Physiol; 2014 Dec; 114(12):2539-49. PubMed ID: 25115506
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimization of the incubator air temperature during LED phototherapy treatment for the preterm infant.
    Yassin FC; Delanaud S; Szcrupak C; Dubos C; Durand E; Tourneux P
    Eur J Pediatr; 2021 Jan; 180(1):277-281. PubMed ID: 32594245
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of forced convection of heated air on insensible water loss and heat loss in preterm infants in incubators.
    Okken A; Blijham C; Franz W; Bohn E
    J Pediatr; 1982 Jul; 101(1):108-12. PubMed ID: 7086609
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiant energy and insensible water loss in the premature newborn infant nursed under a radiant warmer.
    Baumgart S
    Clin Perinatol; 1982 Oct; 9(3):483-503. PubMed ID: 6761034
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thermoregulation: incubators, radiant warmers, artificial skins, and body hoods.
    LeBlanc MH
    Clin Perinatol; 1991 Sep; 18(3):403-22. PubMed ID: 1934849
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.