These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
7. Magnetic resonance imaging of dissolved hyperpolarized 129Xe using a membrane-based continuous flow system. Amor N; Zänker PP; Blümler P; Meise FM; Schreiber LM; Scholz A; Schmiedeskamp J; Spiess HW; Münnemann K J Magn Reson; 2009 Nov; 201(1):93-9. PubMed ID: 19729327 [TBL] [Abstract][Full Text] [Related]
8. Measurement of 129Xe T1 in blood to explore the feasibility of hyperpolarized 129Xe MRI. Albert MS; Schepkin VD; Budinger TF J Comput Assist Tomogr; 1995; 19(6):975-8. PubMed ID: 8537536 [TBL] [Abstract][Full Text] [Related]
9. Signal dynamics in magnetic resonance imaging of the lung with hyperpolarized noble gases. Möller HE; Chen XJ; Chawla MS; Driehuys B; Hedlund LW; Johnson GA J Magn Reson; 1998 Nov; 135(1):133-43. PubMed ID: 9799687 [TBL] [Abstract][Full Text] [Related]
10. Study of gas-fluidization dynamics with laser-polarized 129Xe. Wang R; Rosen MS; Candela D; Mair RW; Walsworth RL Magn Reson Imaging; 2005 Feb; 23(2):203-7. PubMed ID: 15833613 [TBL] [Abstract][Full Text] [Related]
12. Development of hyperpolarized noble gas MRI. Albert MS; Balamore D Nucl Instrum Methods Phys Res A; 1998; 402():441-53. PubMed ID: 11543065 [TBL] [Abstract][Full Text] [Related]
13. Development of a hyperpolarized 129Xe system on 3T for the rat lungs. Sato H; Enmi J; Hayashi T; Takei N; Iwadate Y; Abe S; Teramoto N; Kawachi N; Hattori M; Watabe H; Sawada T; Uchiyama K; Tsukamoto T; Nagasawa K; Iida H Magn Reson Med Sci; 2004 Apr; 3(1):1-9. PubMed ID: 16093614 [TBL] [Abstract][Full Text] [Related]
14. NMR imaging of thermally polarized helium-3 gas. Kober F; Koenigsberg B; Belle V; Viallon M; Leviel JL; Delon A; Ziegler A; Décorps M J Magn Reson; 1999 Jun; 138(2):308-12. PubMed ID: 10341135 [TBL] [Abstract][Full Text] [Related]
15. Hyperpolarized 129Xe phase-selective imaging of mouse lung at 9.4T using a continuous-flow hyperpolarizing system. Wakayama T; Narazaki M; Kimura A; Fujiwara H Magn Reson Med Sci; 2008; 7(2):65-72. PubMed ID: 18603837 [TBL] [Abstract][Full Text] [Related]
16. NMR-based biosensing with optimized delivery of polarized 129Xe to solutions. Han SI; Garcia S; Lowery TJ; Ruiz EJ; Seeley JA; Chavez L; King DS; Wemmer DE; Pines A Anal Chem; 2005 Jul; 77(13):4008-12. PubMed ID: 15987104 [TBL] [Abstract][Full Text] [Related]
17. Hyperpolarized 129 Xe MRI of the mouse lung at a low xenon concentration using a continuous flow-type hyperpolarizing system. Wakayama T; Kitamoto M; Ueyama T; Imai H; Narazaki M; Kimura A; Fujiwara H J Magn Reson Imaging; 2008 Apr; 27(4):777-84. PubMed ID: 18383257 [TBL] [Abstract][Full Text] [Related]