These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
166 related articles for article (PubMed ID: 9179909)
1. Repair of an arterial perforation of the internal carotid artery using Hemashield wrapping with aneurysm clip reinforcement: technical note. Ogilvy CS Neurosurgery; 1997 Jun; 40(6):1312-4. PubMed ID: 9179909 [TBL] [Abstract][Full Text] [Related]
2. Internal carotid artery rotation technique to expose an aneurysm neck: technical note. Hongo K; Tanaka Y; Horiuchi T; Tada T; Kobayashi S Neurosurgery; 2003 Feb; 52(2):455-7; discussion 457. PubMed ID: 12535379 [TBL] [Abstract][Full Text] [Related]
3. Risk of intraoperative aneurysm clip slippage: a new experience with titanium clips. Carvi y Nievas MN; Höllerhage HG J Neurosurg; 2000 Mar; 92(3):478-80. PubMed ID: 10701539 [TBL] [Abstract][Full Text] [Related]
4. Interlocking-clipping technique for giant aneurysms of the internal carotid artery: technical case report. Hashimoto H; Iida J; Masui K; Yonezawa T; Sakaki T Neurosurgery; 1997 Jun; 40(6):1302-4; discussion 1304-6. PubMed ID: 9179907 [TBL] [Abstract][Full Text] [Related]
5. Large dorsal internal carotid artery aneurysm--report of two cases. Diraz A; Kobayashi S; Gibo H; Ohsawa M Neurol Med Chir (Tokyo); 1993 Aug; 33(8):564-7. PubMed ID: 7692330 [TBL] [Abstract][Full Text] [Related]
6. Treatment of giant intracranial aneurysm with carotid ligation, saphenous vein bypass graft. Schmidt JH; Witsberger TA W V Med J; 1992 Aug; 88(8):346-7. PubMed ID: 1514283 [TBL] [Abstract][Full Text] [Related]
7. Temporary aneurysm orifice balloon occlusion as an alternative to retrograde suction decompression for giant paraclinoid internal carotid artery aneurysms: technical note. Steiger HJ; Lins F; Mayer T; Schmid-Elsaesser R; Stummer W; Turowski B Neurosurgery; 2005 Apr; 56(2 Suppl):E442; discussion E442. PubMed ID: 15794846 [TBL] [Abstract][Full Text] [Related]
8. Clipping of proximal paraclinoid aneurysms with support of the balloon-catheter "trapping-evacuation" technique. Technical note. Albert FK; Forsting M; Aschoff A; Krieger D; Kunze S Acta Neurochir (Wien); 1993; 125(1-4):138-41. PubMed ID: 8122538 [TBL] [Abstract][Full Text] [Related]
10. Repair of a tear at the base of a blister-like aneurysm with suturing and an encircling clip: technical note. Yanaka K; Meguro K; Nose T Neurosurgery; 2002 Jan; 50(1):218-21. PubMed ID: 11844255 [TBL] [Abstract][Full Text] [Related]
11. Retrograde Suction Decompression for Clip Occlusion of Internal Carotid Artery Communicating Segment Aneurysms. Takeuchi S; Tanikawa R; Goehre F; Hernesniemi J; Tsuboi T; Noda K; Miyata S; Ota N; Sakakibara F; Andrade-Barazarte H; Kamiyama H World Neurosurg; 2016 May; 89():19-25. PubMed ID: 26806062 [TBL] [Abstract][Full Text] [Related]
14. Delayed aneurysm rupture due to residual blood flow at the inflow zone of the intracranial paraclinoid internal carotid aneurysm treated with the Pipeline embolization device: Histopathological investigation. Ikeda H; Ishii A; Kikuchi T; Ando M; Chihara H; Arai D; Hattori E; Miyamoto S Interv Neuroradiol; 2015 Dec; 21(6):674-83. PubMed ID: 26500232 [TBL] [Abstract][Full Text] [Related]
15. Rupture of cerebral aneurysm during angiography. Karttunen A; Pyhtinen J; Tanska EL; Rönty H Neurochirurgia (Stuttg); 1986 Jan; 29(1):31-3. PubMed ID: 3960253 [TBL] [Abstract][Full Text] [Related]
16. A combination of wrapping and clipping using a collagen-impregnated dacron fabric (Hemashield). Nakano S; Iseda T; Yoneyama T; Ikeda T; Goya T; Wakisaka S Surg Neurol; 2000 Apr; 53(4):330-3. PubMed ID: 10825516 [TBL] [Abstract][Full Text] [Related]
17. Role of intraoperative angiography in the surgical treatment of cerebral aneurysms. Payner TD; Horner TG; Leipzig TJ; Scott JA; Gilmor RL; DeNardo AJ J Neurosurg; 1998 Mar; 88(3):441-8. PubMed ID: 9488297 [TBL] [Abstract][Full Text] [Related]
18. Spontaneous occlusion of supraclinoid aneurysms after the creation of extra-intracranial bypasses using long grafts: report of two cases. Cantore G; Santoro A; Da Pian R Neurosurgery; 1999 Jan; 44(1):216-9; discussion 219-20. PubMed ID: 9894985 [TBL] [Abstract][Full Text] [Related]
19. [On the classification of large and giant paraclinoid internal carotid artery aneurysms]. Shekhtman OD; Eliava SS; Pilipenko YV; Konovalov AN Zh Vopr Neirokhir Im N N Burdenko; 2017; 81(4):17-25. PubMed ID: 28914867 [TBL] [Abstract][Full Text] [Related]
20. Variations in regional cerebral blood flow investigated by single photon emission computed tomography with technetium-99m-d, l-hexamethylpropyleneamineoxime = l-h during temporary clipping in intracranial aneurysm surgery: preliminary results. Medina M; Melcarne A; Musso C; Ettorre F; Bellotti C; Papaleo A; Camuzzini G Neurosurgery; 1993 Sep; 33(3):441-9; discussion 449-50. PubMed ID: 8413876 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]