These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 9183804)

  • 21. Whole-body impedance cardiography in the measurement of cardiac output.
    Kööbi T; Kaukinen S; Turjanmaa VM; Uusitalo AJ
    Crit Care Med; 1997 May; 25(5):779-85. PubMed ID: 9187596
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Methodological guidelines for impedance cardiography.
    Sherwood A; Allen MT; Fahrenberg J; Kelsey RM; Lovallo WR; van Doornen LJ
    Psychophysiology; 1990 Jan; 27(1):1-23. PubMed ID: 2187214
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Simulation study of Kubicek formula for cardiac stroke volume calculation by 3-dimensional finite element method].
    Wang H; Wang J; Dong X; Qi J
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2002 Jan; 19(1):89-92. PubMed ID: 11951532
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output.
    Trinkmann F; Berger M; Doesch C; Papavassiliu T; Schoenberg SO; Borggrefe M; Kaden JJ; Saur J
    J Clin Monit Comput; 2016 Aug; 30(4):399-408. PubMed ID: 26115774
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Signal-morphology impedance cardiography during incremental cardiopulmonary exercise testing in pulmonary arterial hypertension.
    Ferreira EM; Ota-Arakaki JS; Barbosa PB; Siqueira AC; Bravo DM; Kapins CE; Silva CM; Nery LE; Neder JA
    Clin Physiol Funct Imaging; 2012 Sep; 32(5):343-52. PubMed ID: 22856340
    [TBL] [Abstract][Full Text] [Related]  

  • 26. The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients.
    Woltjer HH; Bogaard HJ; van der Spoel HI; de Vries PM
    Intensive Care Med; 1996 Aug; 22(8):766-71. PubMed ID: 8880245
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Measurement of stroke volume with impedance cardiography.
    Milsom I; Sivertsson R; Biber B; Olsson T
    Clin Physiol; 1982 Oct; 2(5):409-17. PubMed ID: 6754214
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Measurement of exercise cardiac output by thoracic impedance in healthy children.
    Pianosi PT
    Eur J Appl Physiol; 2004 Aug; 92(4-5):425-30. PubMed ID: 15221404
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transthoracic impedance cardiography: a noninvasive method of hemodynamic assessment.
    Bayram M; Yancy CW
    Heart Fail Clin; 2009 Apr; 5(2):161-8. PubMed ID: 19249685
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Impedance cardiography--non-invasive measurement of central hemodynamic data].
    Petersen JR; Jensen BV; Olsen F
    Ugeskr Laeger; 1992 Jan; 154(5):255-60. PubMed ID: 1736457
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Impedance cardiography derived cardiac output in hemodialysis patients: a study of reproducibility and comparison with echocardiography.
    Karakitsos DN; Patrianakos AP; Paraskevopoulos A; Parthenakis FI; Tzenakis N; Fourtounas C; Daphnis EK; Vardas PE
    Int J Artif Organs; 2006 Jun; 29(6):564-72. PubMed ID: 16841284
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Assessment of cardiac performance: short- and medium-term variability of impedance cardiography at rest and during dynamic exercise.
    Sundberg S; Akkila J
    Int J Clin Pharmacol Ther; 1996 Mar; 34(3):93-5. PubMed ID: 8705093
    [TBL] [Abstract][Full Text] [Related]  

  • 33. A new ensemble averaging technique in impedance cardiography for estimation of stroke volume during treadmill exercise.
    Kim DW; Song CG; Lee MH
    Front Med Biol Eng; 1992; 4(3):179-88. PubMed ID: 1419917
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Computer supported analysis of cardiovascular parameters by impedance cardiography and plethysmography.
    Hunold S; Hexamer M; Werner J; Gehrt M
    Med Prog Technol; 1993; 19(2):105-13. PubMed ID: 8107666
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Thoracic resistivity for stroke volume calculation in impedance cardiography.
    Quail AW; Traugott FM; Porges WL; White SW
    J Appl Physiol Respir Environ Exerc Physiol; 1981 Jan; 50(1):191-5. PubMed ID: 7204186
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of impedance cardiography and thermodilution-derived measurements of stroke volume and cardiac output at rest and during exercise testing.
    Scherhag A; Kaden JJ; Kentschke E; Sueselbeck T; Borggrefe M
    Cardiovasc Drugs Ther; 2005 Mar; 19(2):141-7. PubMed ID: 16025233
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The measurement of cardiac output by electrical impedance plethysmography in pregnancy. Are the assumptions valid?
    de Swiet M; Talbert DG
    Br J Obstet Gynaecol; 1986 Jul; 93(7):721-6. PubMed ID: 3730343
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Stroke volume measurement by impedance cardiography using a formula based on the delta z waveform.
    Granerus G; Elg R
    Clin Phys Physiol Meas; 1982 May; 3(2):131-9. PubMed ID: 6126290
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Cardiac output by impedance cardiography: two alternative methodologies compared with thermodilution.
    Sherwood A; Carter LS; Murphy CA
    Aviat Space Environ Med; 1991 Feb; 62(2):116-22. PubMed ID: 2001207
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Mechano- and impedance cardiography parameters in patients with heart failure in administration of a calcium antagonist. The significance of the Heather index].
    Linde M; Ohnhaus EE; Kirch W
    Z Kardiol; 1989 Mar; 78(3):181-6. PubMed ID: 2652906
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.