These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 9192940)

  • 1. Instrumental variability of respiratory blood gases among different blood gas analysers in different laboratories.
    Kampelmacher MJ; van Kesteren RG; Winckers EK
    Eur Respir J; 1997 Jun; 10(6):1341-4. PubMed ID: 9192940
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Carbon dioxide and oxygen partial pressure measurements in the cerebrospinal fluid in a conventional blood gas analyzer: analysis of bias and precision.
    Venkatesh B; Boots RJ
    J Neurol Sci; 1997 Mar; 147(1):5-8. PubMed ID: 9094053
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of the i-STAT bedside blood gas analyser.
    Sediame S; Zerah-Lancner F; d'Ortho MP; Adnot S; Harf A
    Eur Respir J; 1999 Jul; 14(1):214-7. PubMed ID: 10489854
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measurement of oxygen and carbon dioxide partial pressures in synovial fluid after tonometry.
    Geborek P; Lindoff B; Valind SO
    Clin Physiol; 1988 Aug; 8(4):427-32. PubMed ID: 3136967
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of blood gas analyzer biases in measuring tonometered blood and a fluorocarbon-containing, proficiency-testing material.
    Hansen JE; Jensen RL; Casaburi R; Crapo RO
    Am Rev Respir Dis; 1989 Aug; 140(2):403-9. PubMed ID: 2504088
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Analytical performances of the i-STAT portable clinical analyzer for the measurement of PO2 and PCO2].
    Sachs C; Finetti P; Rabouine P; Abdoulaye F
    Ann Biol Clin (Paris); 2002; 60(4):411-20. PubMed ID: 12147445
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Multisite evaluation of a continuous intraarterial blood gas monitoring system.
    Larson CP; Vender J; Seiver A
    Anesthesiology; 1994 Sep; 81(3):543-52. PubMed ID: 8092498
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparative study of automatic blood-gas analysers and their use in analysing arterial and capillary samples.
    Rubin P; Bradbury S; Prowse K
    Br Med J; 1979 Jan; 1(6157):156-8. PubMed ID: 33741
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcutaneous monitoring of blood gases: is it comparable with arterialized earlobe sampling?
    Dawson S; Cave C; Pavord I; Potter JF
    Respir Med; 1998 Mar; 92(3):584-7. PubMed ID: 9692127
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Syringe injection pressure: a neglected factor in blood PO2 determination.
    Gosling P; Dickson G
    Ann Clin Biochem; 1990 Mar; 27 ( Pt 2)():147-51. PubMed ID: 2109568
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Blood gas measurement during exercise: a comparative study between arterialized earlobe sampling and direct arterial puncture in adults.
    Fajac I; Texereau J; Rivoal V; Dessanges JF; Dinh-Xuan AT; Dall'Ava-Santucci J
    Eur Respir J; 1998 Mar; 11(3):712-5. PubMed ID: 9596126
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term evaluation of a continuous intra-arterial blood gas monitoring system in patients with severe respiratory failure.
    Kilger E; Briegel J; Schelling G; Polasek J; Manert W; Groh J; Haller M
    Infusionsther Transfusionsmed; 1995 Apr; 22(2):98-104. PubMed ID: 7787410
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Testing of the AVL OPTI 1 portable blood gas analyzer during inflight conditions.
    Maillard D; Ferracci F; Marotte H; Canot S; Minh TT; Finetti P
    Aviat Space Environ Med; 1999 Apr; 70(4):346-50. PubMed ID: 10223272
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Inter-instrument comparison of blood gas analyzers and assessment of tonometry using fresh heparinized whole human blood.
    Van Kessel AL; Eichhorn JH; Clausen JL; Stone ME; Rotman HH; Crapo RO
    Chest; 1987 Sep; 92(3):418-22. PubMed ID: 3622021
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Changes in oxygen measurements when whole blood is stored in iced plastic or glass syringes.
    Mahoney JJ; Harvey JA; Wong RJ; Van Kessel AL
    Clin Chem; 1991 Jul; 37(7):1244-8. PubMed ID: 1823532
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparative study of the electrode systems of three pH and blood gas apparatus.
    Winckers EK; Teunissen AJ; Van den Camp RA; Maas AH
    J Clin Chem Clin Biochem; 1978 Mar; 16(3):175-85. PubMed ID: 25944
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A comparison of four different blood gas analysers.
    Kofstad J
    Scand J Clin Lab Invest; 1981 Jun; 41(4):409-14. PubMed ID: 6797035
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Arterial blood PO2 and PCO2 in horses during early halothane-oxygen anaesthesia.
    Grandy JL; Steffey EP; Miller M
    Equine Vet J; 1987 Jul; 19(4):314-8. PubMed ID: 3113935
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Stability of pO2, pCO2 and pH in heparinized whole blood samples: influence of storage temperature with regard to leukocyte count and syringe material.
    Schmidt C; Müller-Plathe O
    Eur J Clin Chem Clin Biochem; 1992 Nov; 30(11):767-73. PubMed ID: 1489849
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An interlaboratory study of blood-gas analysis: dependence of pO2 and pCO2 results on atmospheric pressure.
    Burnett RW; Itano M
    Clin Chem; 1989 Aug; 35(8):1779-81. PubMed ID: 2503269
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.