210 related articles for article (PubMed ID: 9192940)
1. Instrumental variability of respiratory blood gases among different blood gas analysers in different laboratories. Kampelmacher MJ; van Kesteren RG; Winckers EK Eur Respir J; 1997 Jun; 10(6):1341-4. PubMed ID: 9192940 [TBL] [Abstract][Full Text] [Related]
2. Carbon dioxide and oxygen partial pressure measurements in the cerebrospinal fluid in a conventional blood gas analyzer: analysis of bias and precision. Venkatesh B; Boots RJ J Neurol Sci; 1997 Mar; 147(1):5-8. PubMed ID: 9094053 [TBL] [Abstract][Full Text] [Related]
3. Accuracy of the i-STAT bedside blood gas analyser. Sediame S; Zerah-Lancner F; d'Ortho MP; Adnot S; Harf A Eur Respir J; 1999 Jul; 14(1):214-7. PubMed ID: 10489854 [TBL] [Abstract][Full Text] [Related]
4. Measurement of oxygen and carbon dioxide partial pressures in synovial fluid after tonometry. Geborek P; Lindoff B; Valind SO Clin Physiol; 1988 Aug; 8(4):427-32. PubMed ID: 3136967 [TBL] [Abstract][Full Text] [Related]
5. Comparison of blood gas analyzer biases in measuring tonometered blood and a fluorocarbon-containing, proficiency-testing material. Hansen JE; Jensen RL; Casaburi R; Crapo RO Am Rev Respir Dis; 1989 Aug; 140(2):403-9. PubMed ID: 2504088 [TBL] [Abstract][Full Text] [Related]
6. [Analytical performances of the i-STAT portable clinical analyzer for the measurement of PO2 and PCO2]. Sachs C; Finetti P; Rabouine P; Abdoulaye F Ann Biol Clin (Paris); 2002; 60(4):411-20. PubMed ID: 12147445 [TBL] [Abstract][Full Text] [Related]
7. Multisite evaluation of a continuous intraarterial blood gas monitoring system. Larson CP; Vender J; Seiver A Anesthesiology; 1994 Sep; 81(3):543-52. PubMed ID: 8092498 [TBL] [Abstract][Full Text] [Related]
8. Comparative study of automatic blood-gas analysers and their use in analysing arterial and capillary samples. Rubin P; Bradbury S; Prowse K Br Med J; 1979 Jan; 1(6157):156-8. PubMed ID: 33741 [TBL] [Abstract][Full Text] [Related]
9. Transcutaneous monitoring of blood gases: is it comparable with arterialized earlobe sampling? Dawson S; Cave C; Pavord I; Potter JF Respir Med; 1998 Mar; 92(3):584-7. PubMed ID: 9692127 [TBL] [Abstract][Full Text] [Related]
10. Syringe injection pressure: a neglected factor in blood PO2 determination. Gosling P; Dickson G Ann Clin Biochem; 1990 Mar; 27 ( Pt 2)():147-51. PubMed ID: 2109568 [TBL] [Abstract][Full Text] [Related]
11. Blood gas measurement during exercise: a comparative study between arterialized earlobe sampling and direct arterial puncture in adults. Fajac I; Texereau J; Rivoal V; Dessanges JF; Dinh-Xuan AT; Dall'Ava-Santucci J Eur Respir J; 1998 Mar; 11(3):712-5. PubMed ID: 9596126 [TBL] [Abstract][Full Text] [Related]
12. Long-term evaluation of a continuous intra-arterial blood gas monitoring system in patients with severe respiratory failure. Kilger E; Briegel J; Schelling G; Polasek J; Manert W; Groh J; Haller M Infusionsther Transfusionsmed; 1995 Apr; 22(2):98-104. PubMed ID: 7787410 [TBL] [Abstract][Full Text] [Related]
13. Testing of the AVL OPTI 1 portable blood gas analyzer during inflight conditions. Maillard D; Ferracci F; Marotte H; Canot S; Minh TT; Finetti P Aviat Space Environ Med; 1999 Apr; 70(4):346-50. PubMed ID: 10223272 [TBL] [Abstract][Full Text] [Related]
14. Inter-instrument comparison of blood gas analyzers and assessment of tonometry using fresh heparinized whole human blood. Van Kessel AL; Eichhorn JH; Clausen JL; Stone ME; Rotman HH; Crapo RO Chest; 1987 Sep; 92(3):418-22. PubMed ID: 3622021 [TBL] [Abstract][Full Text] [Related]
15. Changes in oxygen measurements when whole blood is stored in iced plastic or glass syringes. Mahoney JJ; Harvey JA; Wong RJ; Van Kessel AL Clin Chem; 1991 Jul; 37(7):1244-8. PubMed ID: 1823532 [TBL] [Abstract][Full Text] [Related]
16. A comparative study of the electrode systems of three pH and blood gas apparatus. Winckers EK; Teunissen AJ; Van den Camp RA; Maas AH J Clin Chem Clin Biochem; 1978 Mar; 16(3):175-85. PubMed ID: 25944 [TBL] [Abstract][Full Text] [Related]
17. A comparison of four different blood gas analysers. Kofstad J Scand J Clin Lab Invest; 1981 Jun; 41(4):409-14. PubMed ID: 6797035 [TBL] [Abstract][Full Text] [Related]
18. Arterial blood PO2 and PCO2 in horses during early halothane-oxygen anaesthesia. Grandy JL; Steffey EP; Miller M Equine Vet J; 1987 Jul; 19(4):314-8. PubMed ID: 3113935 [TBL] [Abstract][Full Text] [Related]
19. Stability of pO2, pCO2 and pH in heparinized whole blood samples: influence of storage temperature with regard to leukocyte count and syringe material. Schmidt C; Müller-Plathe O Eur J Clin Chem Clin Biochem; 1992 Nov; 30(11):767-73. PubMed ID: 1489849 [TBL] [Abstract][Full Text] [Related]
20. An interlaboratory study of blood-gas analysis: dependence of pO2 and pCO2 results on atmospheric pressure. Burnett RW; Itano M Clin Chem; 1989 Aug; 35(8):1779-81. PubMed ID: 2503269 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]