These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 9195320)

  • 21. Femoral component offset. Its effect on strain in bone-cement.
    Davey JR; O'Connor DO; Burke DW; Harris WH
    J Arthroplasty; 1993 Feb; 8(1):23-6. PubMed ID: 8436985
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Analysis of cement mantles in collared versus collarless femoral components.
    Mahoney CR; Yun AG; Pellicci PM
    Am J Orthop (Belle Mead NJ); 2006 May; 35(5):235-6. PubMed ID: 16764183
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Reinforcement of bone cement around the femoral prosthesis tip by pre-coated wire coil: a human cadaver bone study.
    Kim JK; Park JB
    Biomed Mater Eng; 1996; 6(3):159-64. PubMed ID: 8922261
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Recementing a femoral component into a stable cement mantle using ultrasonic tools.
    McCallum JD; Hozack WJ
    Clin Orthop Relat Res; 1995 Oct; (319):232-7. PubMed ID: 7554635
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Hybrid total hip arthroplasty with a precoated offset stem. Four to nine-year results.
    Cannestra VP; Berger RA; Quigley LR; Jacobs JJ; Rosenberg AG; Galante JO
    J Bone Joint Surg Am; 2000 Sep; 82(9):1291-9. PubMed ID: 11005520
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Femoral cement grading in total hip arthroplasty.
    Harvey EJ; Tanzer M; Bobyn JD
    J Arthroplasty; 1998 Jun; 13(4):396-401. PubMed ID: 9645519
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Cement-in-cement revision of the femoral stem: analysis of 1179 first-time revisions in the Swedish Hip Arthroplasty Register.
    Cnudde PH; Kärrholm J; Rolfson O; Timperley AJ; Mohaddes M
    Bone Joint J; 2017 Apr; 99-B(4 Supple B):27-32. PubMed ID: 28363891
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Clinical and radiological evaluation of revision hip arthroplasty using the cement-in-cement technique.
    Goto K; Kawanabe K; Akiyama H; Morimoto T; Nakamura T
    J Bone Joint Surg Br; 2008 Aug; 90(8):1013-8. PubMed ID: 18669955
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Roentgenographic and mechanical performance of centrifuged cement in a simulated total hip arthroplasty model.
    Chao EY; Chin HC; Stauffer RN
    Clin Orthop Relat Res; 1992 Dec; (285):91-101. PubMed ID: 1446460
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Anatomic stem design reduces risk of thin cement mantles in primary hip replacement.
    Hank C; Schneider M; Achary CS; Smith L; Breusch SJ
    Arch Orthop Trauma Surg; 2010 Jan; 130(1):17-22. PubMed ID: 19513737
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Primary total hip replacement with insertion of an acetabular component without cement and a femoral component with cement. Follow-up study at an average of six years.
    Woolson ST; Haber DF
    J Bone Joint Surg Am; 1996 May; 78(5):698-705. PubMed ID: 8642026
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effects of distal cement voids on cement stress in total hip arthroplasty.
    Powers CM; Lee IY; Skinner HB; Keyak JH
    J Arthroplasty; 1998 Oct; 13(7):793-8. PubMed ID: 9802667
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Revision total hip arthroplasty with the BIAS (Biologic Ingrowth Anatomic System) femoral component. Three to six-year results.
    Hussamy O; Lachiewicz PF
    J Bone Joint Surg Am; 1994 Aug; 76(8):1137-48. PubMed ID: 8056794
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Impact of stem-broach sizing on the cement mantle of Lubinus SP II stems. A CT scan analysis.
    Scheerlinck T; de Mey J; Deklerck R
    Acta Orthop Belg; 2009 Jun; 75(3):346-53. PubMed ID: 19681321
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Charnley total hip arthroplasty with cement. Minimum twenty-five-year follow-up.
    Callaghan JJ; Albright JC; Goetz DD; Olejniczak JP; Johnston RC
    J Bone Joint Surg Am; 2000 Apr; 82(4):487-97. PubMed ID: 10761939
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Radiologic aspects of the loosening of cemented hip prostheses: mechanical, septic or granulomatous etiology?].
    Malghem J; Mosseray A; Vande Berg B; Lebon C; Maldague B
    J Belge Radiol; 1997 Aug; 80(4):173-84. PubMed ID: 9410868
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of a distal centralizer on the positioning of an anatomical stem.
    Bell CA; Pilot P; van den Boogaart M; Verburg AD
    Acta Orthop Belg; 2009 Feb; 75(1):41-4. PubMed ID: 19358397
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Custom-made molds that prevent cement extrusion through bone defects.
    Slater RR; Morrison J; Kelley SS
    Clin Orthop Relat Res; 1995 Aug; (317):126-30. PubMed ID: 7671466
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Revision total hip arthroplasty without cement: subsidence of proximally porous-coated femoral components.
    Peters CL; Rivero DP; Kull LR; Jacobs JJ; Rosenberg AG; Galante JO
    J Bone Joint Surg Am; 1995 Aug; 77(8):1217-26. PubMed ID: 7642668
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement. An average ten-year follow-up study.
    Clohisy JC; Harris WH
    J Bone Joint Surg Am; 1999 Feb; 81(2):247-55. PubMed ID: 10073588
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.