These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
278 related articles for article (PubMed ID: 9197099)
1. Temperature rise during drilling through bone. Abouzgia MB; James DF Int J Oral Maxillofac Implants; 1997; 12(3):342-53. PubMed ID: 9197099 [TBL] [Abstract][Full Text] [Related]
2. Effect of drill speed on bone temperature. Abouzgia MB; Symington JM Int J Oral Maxillofac Surg; 1996 Oct; 25(5):394-9. PubMed ID: 8961026 [TBL] [Abstract][Full Text] [Related]
3. Heat generation during implant site preparation: an in vitro study. Cordioli G; Majzoub Z Int J Oral Maxillofac Implants; 1997; 12(2):186-93. PubMed ID: 9109268 [TBL] [Abstract][Full Text] [Related]
4. The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Brisman DL Int J Oral Maxillofac Implants; 1996; 11(1):35-7. PubMed ID: 8820120 [TBL] [Abstract][Full Text] [Related]
5. Measurements of shaft speed while drilling through bone. Abouzgia MB; James DF J Oral Maxillofac Surg; 1995 Nov; 53(11):1308-15; discussion 1315-6. PubMed ID: 7562196 [TBL] [Abstract][Full Text] [Related]
6. In vitro comparison of cortical bone temperature generation between traditional sequential drilling and a newly designed step drill in the equine third metacarpal bone. Bubeck KA; García-López J; Maranda LS Vet Comp Orthop Traumatol; 2009; 22(6):442-7. PubMed ID: 19876527 [TBL] [Abstract][Full Text] [Related]
7. Heat production by 3 implant drill systems after repeated drilling and sterilization. Chacon GE; Bower DL; Larsen PE; McGlumphy EA; Beck FM J Oral Maxillofac Surg; 2006 Feb; 64(2):265-9. PubMed ID: 16413899 [TBL] [Abstract][Full Text] [Related]
8. Effect of feed rate and drill speed on temperatures in equine cortical bone. Toews AR; Bailey JV; Townsend HG; Barber SM Am J Vet Res; 1999 Aug; 60(8):942-4. PubMed ID: 10451201 [TBL] [Abstract][Full Text] [Related]
10. Effect of surgical drill guide on heat generated from implant drilling. Misir AF; Sumer M; Yenisey M; Ergioglu E J Oral Maxillofac Surg; 2009 Dec; 67(12):2663-8. PubMed ID: 19925988 [TBL] [Abstract][Full Text] [Related]
11. Comparison of heat generation between internally guided (cannulated) single drill and traditional sequential drilling with and without a drill guide for dental implants. Bulloch SE; Olsen RG; Bulloch B Int J Oral Maxillofac Implants; 2012; 27(6):1456-60. PubMed ID: 23189297 [TBL] [Abstract][Full Text] [Related]
12. Heat distribution in bone during preparation of implant sites: heat analysis by real-time thermography. Watanabe F; Tawada Y; Komatsu S; Hata Y Int J Oral Maxillofac Implants; 1992; 7(2):212-9. PubMed ID: 1398838 [TBL] [Abstract][Full Text] [Related]
13. Effects of bone drilling on local temperature and bone regeneration: an in vivo study. Karaca F; Aksakal B; Köm M Acta Orthop Traumatol Turc; 2014; 48(3):326-32. PubMed ID: 24901925 [TBL] [Abstract][Full Text] [Related]
14. Determination of spatial distribution of increase in bone temperature during drilling by infrared thermography: preliminary report. Augustin G; Davila S; Udiljak T; Vedrina DS; Bagatin D Arch Orthop Trauma Surg; 2009 May; 129(5):703-9. PubMed ID: 18421465 [TBL] [Abstract][Full Text] [Related]
15. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs. Marković A; Lazić Z; Mišić T; Šćepanović M; Todorović A; Thakare K; Janjić B; Vlahović Z; Glišić M Vojnosanit Pregl; 2016 Aug; 73(8):744-50. PubMed ID: 29328609 [TBL] [Abstract][Full Text] [Related]
16. Experimental and analytical investigation of the thermal necrosis in high-speed drilling of bone. Shakouri E; Sadeghi MH; Maerefat M; Shajari S Proc Inst Mech Eng H; 2014 Apr; 228(4):330-41. PubMed ID: 24569922 [TBL] [Abstract][Full Text] [Related]
17. Investigation of the effect of movement and irrigation systems on temperature in the conventional drilling of cortical bone. Gehrke SA; Loffredo Neto H; Mardegan FE Br J Oral Maxillofac Surg; 2013 Dec; 51(8):953-7. PubMed ID: 23434270 [TBL] [Abstract][Full Text] [Related]
18. Heat accumulation during sequential cortical bone drilling. Palmisano AC; Tai BL; Belmont B; Irwin TA; Shih A; Holmes JR J Orthop Res; 2016 Mar; 34(3):463-70. PubMed ID: 26334198 [TBL] [Abstract][Full Text] [Related]
19. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Ercoli C; Funkenbusch PD; Lee HJ; Moss ME; Graser GN Int J Oral Maxillofac Implants; 2004; 19(3):335-49. PubMed ID: 15214217 [TBL] [Abstract][Full Text] [Related]
20. Effects of various drilling parameters on bone during implantology: An in vitro experimental study. Karaca F; Aksakal B Acta Bioeng Biomech; 2013; 15(4):25-32. PubMed ID: 24479623 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]