These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

354 related articles for article (PubMed ID: 9198443)

  • 21. Alteration in the inherent metallic and surface properties of nickel-titanium root canal instruments to enhance performance, durability and safety: a focused review.
    Gutmann JL; Gao Y
    Int Endod J; 2012 Feb; 45(2):113-28. PubMed ID: 21902705
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Three-dimensional analysis of cutting behavior of nickel-titanium rotary instruments by microcomputed tomography.
    Shen Y; Haapasalo M
    J Endod; 2008 May; 34(5):606-10. PubMed ID: 18436045
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status report for the American Journal of Dentistry.
    Bergmans L; Van Cleynenbreugel J; Wevers M; Lambrechts P
    Am J Dent; 2001 Oct; 14(5):324-33. PubMed ID: 11803999
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Deformation and fracture of Mtwo rotary nickel-titanium instruments after clinical use.
    Inan U; Gonulol N
    J Endod; 2009 Oct; 35(10):1396-9. PubMed ID: 19801238
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests.
    Plotino G; Grande NM; Cordaro M; Testarelli L; Gambarini G
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Sep; 108(3):e152-6. PubMed ID: 19716485
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Microstructure, nickel suppression and mechanical characteristics of electropolished and photoelectrocatalytically oxidized biomedical nickel titanium shape memory alloy.
    Chu CL; Guo C; Sheng XB; Dong YS; Lin PH; Yeung KW; Chu PK
    Acta Biomater; 2009 Jul; 5(6):2238-45. PubMed ID: 19251496
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Fatigue and mechanical properties of nickel-titanium endodontic instruments.
    Kuhn G; Jordan L
    J Endod; 2002 Oct; 28(10):716-20. PubMed ID: 12398171
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments.
    Miyai K; Ebihara A; Hayashi Y; Doi H; Suda H; Yoneyama T
    Int Endod J; 2006 Feb; 39(2):119-26. PubMed ID: 16454792
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effect of heat treatment on transformation temperatures and bending properties of nickel-titanium endodontic instruments.
    Yahata Y; Yoneyama T; Hayashi Y; Ebihara A; Doi H; Hanawa T; Suda H
    Int Endod J; 2009 Jul; 42(7):621-6. PubMed ID: 19467049
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The LightSpeed system.
    Barbakow F
    Dent Clin North Am; 2004 Jan; 48(1):113-35. PubMed ID: 15066510
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Phase transformation behaviour and bending property of twisted nickel-titanium endodontic instruments.
    Hou X; Yahata Y; Hayashi Y; Ebihara A; Hanawa T; Suda H
    Int Endod J; 2011 Mar; 44(3):253-8. PubMed ID: 21219356
    [TBL] [Abstract][Full Text] [Related]  

  • 32. A comparison of stainless steel and nickel-titanium H-type instruments of identical design: torsional and bending tests.
    Kazemi RB; Stenman E; Spångberg LS
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2000 Oct; 90(4):500-6. PubMed ID: 11027388
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In-depth hardness profiles of stainless steel and Ni-Ti endodontic instrument cross-sections by nano-indentation.
    Zinelis S; Akhtar R; Tsakiridis P; Watts DC; Silikas N
    Int Endod J; 2008 Sep; 41(9):747-54. PubMed ID: 18637851
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Mechanical properties of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment.
    Haïkel Y; Serfaty R; Wilson P; Speisser JM; Allemann C
    J Endod; 1998 Nov; 24(11):731-5. PubMed ID: 9855823
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison between a novel nickel-titanium alloy and 508 nitinol on the cyclic fatigue life of ProFile 25/.04 rotary instruments.
    Johnson E; Lloyd A; Kuttler S; Namerow K
    J Endod; 2008 Nov; 34(11):1406-1409. PubMed ID: 18928858
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Properties of endodontic hand instruments used in rotary motion. Part 3. Resistance to bending and fracture.
    Tepel J; Schäfer E; Hoppe W
    J Endod; 1997 Mar; 23(3):141-5. PubMed ID: 9594751
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Does electropolishing improve the low-cycle fatigue behavior of a nickel-titanium rotary instrument in hypochlorite?
    Cheung GS; Shen Y; Darvell BW
    J Endod; 2007 Oct; 33(10):1217-21. PubMed ID: 17889693
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Nickel-titanium: options and challenges.
    Baumann MA
    Dent Clin North Am; 2004 Jan; 48(1):55-67. PubMed ID: 15066507
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparative study of torsional and bending properties for six models of nickel-titanium root canal instruments with different cross-sections.
    Xu X; Eng M; Zheng Y; Eng D
    J Endod; 2006 Apr; 32(4):372-5. PubMed ID: 16554216
    [TBL] [Abstract][Full Text] [Related]  

  • 40. HyFlex nickel-titanium rotary instruments after clinical use: metallurgical properties.
    Shen Y; Coil JM; Zhou H; Zheng Y; Haapasalo M
    Int Endod J; 2013 Aug; 46(8):720-9. PubMed ID: 23330612
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 18.