BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

166 related articles for article (PubMed ID: 9201524)

  • 1. Validation of air tonometric measurement of gastric regional concentrations of CO2 in critically ill septic patients.
    Heinonen PO; Jousela IT; Blomqvist KA; Olkkola KT; Takkunen OS
    Intensive Care Med; 1997 May; 23(5):524-9. PubMed ID: 9201524
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of air tonometry with gastric tonometry using saline and other equilibrating fluids: an in vivo and in vitro study.
    Barry B; Mallick A; Hartley G; Bodenham A; Vucevic M
    Intensive Care Med; 1998 Aug; 24(8):777-84. PubMed ID: 9757920
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro evaluation of intragastric PCO2 measurement by air tonometry.
    Kolkman JJ; Zwaarekant LJ; Boshuizen K; Groeneveld AB; Meuwissen SG
    J Clin Monit; 1997 Mar; 13(2):115-9. PubMed ID: 9112207
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monitoring gastric mucosal carbon dioxide pressure using gas tonometry: in vitro and in vivo validation studies.
    Creteur J; De Backer D; Vincent JL
    Anesthesiology; 1997 Sep; 87(3):504-10. PubMed ID: 9316953
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Catheter deadspace: a source of error during tonometry.
    Steverink PJ; Kolkman JJ; Groeneveld AB; de Vries JW
    Br J Anaesth; 1998 Mar; 80(3):337-41. PubMed ID: 9623434
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intraluminal "balloonless" air tonometry: a new method for determination of gastrointestinal mucosal carbon dioxide tension.
    Salzman AL; Strong KE; Wang H; Wollert PS; Vandermeer TJ; Fink MP
    Crit Care Med; 1994 Jan; 22(1):126-34. PubMed ID: 8124955
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of gastric air tonometry with standard saline tonometry.
    Tzelepis G; Kadas V; Michalopoulos A; Geroulanos S
    Intensive Care Med; 1996 Nov; 22(11):1239-43. PubMed ID: 9120119
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of hypothermia on calculated values using saline and automated air tonometry.
    Chapman MV; Woolf RL; Bennett-Guerrero E; Mythen MG
    J Cardiothorac Vasc Anesth; 2002 Jun; 16(3):304-7. PubMed ID: 12073201
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of air as an equilibration medium in gastric tonometry: an in vitro evaluation of two techniques for measuring air PCO2.
    Venkatesh B; Morgan J; Jones RD; Clague A
    Anaesth Intensive Care; 1998 Feb; 26(1):46-50. PubMed ID: 9513667
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gastric tonometry: precision and reliability are improved by a phosphate buffered solution.
    Knichwitz G; Kuhmann M; Brodner G; Mertes N; Goeters C; Brüssel T
    Crit Care Med; 1996 Mar; 24(3):512-6. PubMed ID: 8625643
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Continuous assessment of gastric intramucosal PCO2 and pH in hemorrhagic shock using capnometric recirculating gas tonometry.
    Guzman JA; Kruse JA
    Crit Care Med; 1997 Mar; 25(3):533-7. PubMed ID: 9118673
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of a point-of-care blood gas analyzer in gastric tonometry measurements of intramucosal pH (pHi) and P(CO2) gap.
    Dohgomori H; Arikawa K; Kanmura Y
    J Anesth; 2004; 18(1):14-7. PubMed ID: 14991470
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Advantage of buffered solutions or automated capnometry in air-filled balloons for use in gastric tonometry.
    Temmesfeld-Wollbrück B; Szalay A; Olschewski H; Grimminger F; Seeger W
    Intensive Care Med; 1997 Apr; 23(4):423-7. PubMed ID: 9142582
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vitro validation of gastric air tonometry using perfluorocarbon FC 43 and 0.9% sodium chloride.
    Graf J; Königs B; Mottaghy K; Janssens U
    Br J Anaesth; 2000 Apr; 84(4):497-9. PubMed ID: 10823103
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Continuous fiberoptic PCO2 monitoring indicates poorer gastric perfusion during supraceliac aortic clamping than conventional gastric tonometry in humans: a pilot study.
    Melton A
    J Cardiothorac Vasc Anesth; 2000 Dec; 14(6):666-71. PubMed ID: 11139106
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Gastric mucosal tonometry: towards new methods and applications.
    Mythen MG; Woolf R; Noone RB
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 Jun; 33 Suppl 2():S85-90. PubMed ID: 9689412
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Factors affecting performance of air tonometry using the TONOCAP.
    Dullenkopf A; Cornelius A; Gerber AC; Weiss M
    Anaesth Intensive Care; 2002 Dec; 30(6):794-9. PubMed ID: 12500520
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gastric tonometry and monitoring gastrointestinal perfusion: using research to support nursing practice.
    Marshall AP; West SH
    Nurs Crit Care; 2004; 9(3):123-33. PubMed ID: 15152754
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [PCO2 tonometry of the stomach].
    Otte JA; Kolkman JJ; Groeneveld AB
    Ned Tijdschr Geneeskd; 2000 Dec; 144(49):2341-5. PubMed ID: 11129968
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the 5-French saline paediatric gastric tonometer.
    Thorburn K; Hatherill M; Roberts PC; Durward A; Tibby SM; Murdoch IA
    Intensive Care Med; 2000 Jul; 26(7):973-80. PubMed ID: 10990115
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.