These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
150 related articles for article (PubMed ID: 9205157)
1. Aortic valve replacement with patch enlargement of the aortic annulus. Sommers KE; David TE Ann Thorac Surg; 1997 Jun; 63(6):1608-12. PubMed ID: 9205157 [TBL] [Abstract][Full Text] [Related]
2. Stability of aortic annulus enlargement during aortic valve replacement using a bovine pericardial patch: an 18-year clinical, echocardiographic, and angio-computed tomographic follow-up. Celiento M; Saccocci M; De Martino A; Nardi C; Faggioni L; Milano AD; Bortolotti U J Thorac Cardiovasc Surg; 2014 Mar; 147(3):977-83. PubMed ID: 23540656 [TBL] [Abstract][Full Text] [Related]
4. Long-Term Results of Pericardial Autologous Patch Enlargement of the Aortic Annulus Using the Manouguian Technique. Demïrtürk OS; Kiziltan HT; Coşkun İ; Tünel HA; Tekin HG Heart Surg Forum; 2016 Apr; 19(2):E067-73. PubMed ID: 27146233 [TBL] [Abstract][Full Text] [Related]
5. Enlargement of the aortic annulus with glutaraldehyde-fixed bovine pericardium during aortic valve replacement. Bortolotti U; Scioti G; Milano A; Nardi C; Tartarini G J Heart Valve Dis; 1998 May; 7(3):299-304. PubMed ID: 9651843 [TBL] [Abstract][Full Text] [Related]
6. Enlargement of the small aortic root during aortic valve replacement: is there a benefit? Kulik A; Al-Saigh M; Chan V; Masters RG; Bédard P; Lam BK; Rubens FD; Hendry PJ; Mesana TG; Ruel M Ann Thorac Surg; 2008 Jan; 85(1):94-100. PubMed ID: 18154789 [TBL] [Abstract][Full Text] [Related]
7. Midterm results of Manouguian double valve replacement: comparison with standard double valve replacement. Okuyama H; Hashimoto K; Kurosawa H; Tanaka K; Sakamoto Y; Shiratori K J Thorac Cardiovasc Surg; 2005 Apr; 129(4):869-74. PubMed ID: 15821656 [TBL] [Abstract][Full Text] [Related]
8. Isolated aortic valve replacement in patients with small aortic annulus-a high-risk group on long-term follow-up. Wilbring M; Alexiou K; Schumann E; Matschke K; Tugtekin SM Thorac Cardiovasc Surg; 2013 Aug; 61(5):379-85. PubMed ID: 23258763 [TBL] [Abstract][Full Text] [Related]
9. Rigorous patient-prosthesis matching of Perimount Magna aortic bioprosthesis. Nakamura H; Yamaguchi H; Takagaki M; Kadowaki T; Nakao T; Amano A Asian Cardiovasc Thorac Ann; 2015 Mar; 23(3):261-6. PubMed ID: 25033914 [TBL] [Abstract][Full Text] [Related]
10. Aortic valve replacement with anterior and posterior enlargement of small aortic annulus is comparable to surgery with normal annulus. Sant'anna JR; de Bacco FW; Santánna RT; Kalil RA; Prates PR; Nesralla IA Rev Port Cardiol; 2006 Jun; 25(6):593-602. PubMed ID: 17019978 [TBL] [Abstract][Full Text] [Related]
11. Use of bovine pericardial tissue for aortic valve and aortic root replacement: long-term results. Vrandecic M; Gontijo Filho B; Fantini F; Barbosa J; Martins I; de Oliveira OC; Martins C; Max R; Drumond L; Oliveira C; Ferrufino A; Alcocer E; Silva JA; Vrandecic E J Heart Valve Dis; 1998 Mar; 7(2):195-201. PubMed ID: 9587861 [TBL] [Abstract][Full Text] [Related]
12. [Advantage of supra-annular patch enlargement in aortic stenosis with a small aortic annulus]. Hamasaki A; Yaginuma G Kyobu Geka; 2006 Apr; 59(4):289-93. PubMed ID: 16613146 [TBL] [Abstract][Full Text] [Related]
13. Outcomes of a New-Generation Stentless Aortic Valve: A Single-Center Experience with 251 Consecutive Implants. Stefanelli G; Pirro F; Danniballe G; Olaru A; Meli M; Weltert L J Heart Valve Dis; 2017 Sep; 26(5):518-527. PubMed ID: 29762920 [TBL] [Abstract][Full Text] [Related]
14. [Aortic valve replacement for the small aortic annulus]. Oshima H; Usui A; Akita T; Ueda Y Kyobu Geka; 2006 Apr; 59(4):269-75. PubMed ID: 16613143 [TBL] [Abstract][Full Text] [Related]
15. [Valve Re-replacement Combined with Patch Enlargement of the Aortic Annulus for Bioprosthetic Valve Deterioration;Report of a Case]. Akabane K; Uchino H; Kim C; Nakamura K; Hirooka S; Ochiai T; Shimanuki T Kyobu Geka; 2020 Oct; 73(11):940-943. PubMed ID: 33130719 [TBL] [Abstract][Full Text] [Related]
16. Comparison of Aortic Annulus Dimension After Aortic Valve Neocuspidization With Valve Replacement and Normal Valve. Yamamoto Y; Iino K; Shintani Y; Kato H; Kimura K; Watanabe G; Takemura H Semin Thorac Cardiovasc Surg; 2017 Summer; 29(2):143-149. PubMed ID: 28823320 [TBL] [Abstract][Full Text] [Related]
17. Comparable long-term results for porcine and pericardial prostheses after isolated aortic valve replacement. Andreas M; Wallner S; Ruetzler K; Wiedemann D; Ehrlich M; Heinze G; Binder T; Moritz A; Hiesmayr MJ; Kocher A; Laufer G Eur J Cardiothorac Surg; 2015 Oct; 48(4):557-61. PubMed ID: 25527170 [TBL] [Abstract][Full Text] [Related]
18. Nineteen-millimeter aortic St. Jude Medical heart valve prosthesis: up to sixteen years' follow-up. Sawant D; Singh AK; Feng WC; Bert AA; Rotenberg F Ann Thorac Surg; 1997 Apr; 63(4):964-70. PubMed ID: 9124972 [TBL] [Abstract][Full Text] [Related]
19. An appraisal of patch enlargement of the small aortic annulus in 33 patients undergoing aortic valve replacement. Nakano S; Matsuda H; Shimazaki Y; Taniguchi K; Kaneko M; Ueda T; Mori T; Kawashima Y Eur J Cardiothorac Surg; 1992; 6(7):347-9. PubMed ID: 1497925 [TBL] [Abstract][Full Text] [Related]
20. The use of pericardium in acquired heart disease: a review article. David TE J Heart Valve Dis; 1998 Jan; 7(1):13-8. PubMed ID: 9502133 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]