BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 9212387)

  • 1. Intramedullary implant of plasma-sprayed hydroxyapatite coating: an interface study.
    Yang CY; Wang BC; Lee TM; Chang E; Chang GL
    J Biomed Mater Res; 1997 Jul; 36(1):39-48. PubMed ID: 9212387
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hydroxyapatite-coating on titanium arc sprayed titanium implants.
    Nakashima Y; Hayashi K; Inadome T; Uenoyama K; Hara T; Kanemaru T; Sugioka Y; Noda I
    J Biomed Mater Res; 1997 Jun; 35(3):287-98. PubMed ID: 9138063
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The shear strength and the failure mode of plasma-sprayed hydroxyapatite coating to bone: the effect of coating thickness.
    Wang BC; Lee TM; Chang E; Yang CY
    J Biomed Mater Res; 1993 Oct; 27(10):1315-27. PubMed ID: 8245046
    [TBL] [Abstract][Full Text] [Related]  

  • 4. In vitro and in vivo mechanical evaluations of plasma-sprayed hydroxyapatite coatings on titanium implants: the effect of coating characteristics.
    Yang CY; Lin RM; Wang BC; Lee TM; Chang E; Hang YS; Chen PQ
    J Biomed Mater Res; 1997 Dec; 37(3):335-45. PubMed ID: 9368138
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of residual stress on the shear strength between the bone and plasma-sprayed hydroxyapatite coating.
    Yang YC; Yang CY
    J Mater Sci Mater Med; 2008 Mar; 19(3):1051-60. PubMed ID: 17701301
    [TBL] [Abstract][Full Text] [Related]  

  • 6. In vitro and in vivo biological responses of plasma-sprayed hydroxyapatite coatings with posthydrothermal treatment.
    Yang CY; Lee TM; Yang CW; Chen LR; Wu MC; Lui TS
    J Biomed Mater Res A; 2007 Nov; 83(2):263-71. PubMed ID: 17415765
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Mechanical failure of hydroxyapatite- and polysulfone-coated titanium rods in a weight-bearing canine model.
    Shen WJ; Chung KC; Wang GJ; McLaughlin RE
    J Arthroplasty; 1992 Mar; 7(1):43-9. PubMed ID: 1314288
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants.
    Dalton JE; Cook SD; Thomas KA; Kay JF
    J Bone Joint Surg Am; 1995 Jan; 77(1):97-110. PubMed ID: 7822360
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of plasma-sprayed hydroxyapatite coatings and zirconia-reinforced hydroxyapatite composite coatings: in vivo study.
    Lee TM; Yang CY; Chang E; Tsai RS
    J Biomed Mater Res A; 2004 Dec; 71(4):652-60. PubMed ID: 15505828
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mechanical and histological evaluation of amorphous calcium phosphate and poorly crystallized hydroxyapatite coatings on titanium implants.
    Maxian SH; Zawadsky JP; Dunn MG
    J Biomed Mater Res; 1993 Jun; 27(6):717-28. PubMed ID: 8408101
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Histological and mechanical comparison of hydroxyapatite-coated cobalt-chrome and titanium implants in the rabbit femur.
    Friedman RJ; Bauer TW; Garg K; Jiang M; An YH; Draughn RA
    J Appl Biomater; 1995; 6(4):231-5. PubMed ID: 8589507
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of plasma-sprayed hydroxyapatite coatings and hydroxyapatite/tricalcium phosphate composite coatings: in vivo study.
    Lee TM; Wang BC; Yang YC; Chang E; Yang CY
    J Biomed Mater Res; 2001 Jun; 55(3):360-7. PubMed ID: 11255189
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of surface roughness of hydroxyapatite-coated titanium on the bone-implant interface shear strength.
    Hayashi K; Inadome T; Tsumura H; Nakashima Y; Sugioka Y
    Biomaterials; 1994 Nov; 15(14):1187-91. PubMed ID: 7534485
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Hydroxyapatite-coated titanium for orthopedic implant applications.
    Cook SD; Thomas KA; Kay JF; Jarcho M
    Clin Orthop Relat Res; 1988 Jul; (232):225-43. PubMed ID: 2838208
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of bone-implant interface shear strength of hydroxyapatite-coated and alumina-coated metal implants.
    Inadome T; Hayashi K; Nakashima Y; Tsumura H; Sugioka Y
    J Biomed Mater Res; 1995 Jan; 29(1):19-24. PubMed ID: 7713954
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of residual stress on bonding strength and fracture of plasma-sprayed hydroxyapatite coatings on Ti-6Al-4V substrate.
    Yang YC; Chang E
    Biomaterials; 2001 Jul; 22(13):1827-36. PubMed ID: 11396887
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials.
    Thomas KA; Kay JF; Cook SD; Jarcho M
    J Biomed Mater Res; 1987 Dec; 21(12):1395-414. PubMed ID: 3429474
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Relative contributions of chemistry and topography to the osseointegration of hydroxyapatite coatings.
    Hacking SA; Tanzer M; Harvey EJ; Krygier JJ; Bobyn JD
    Clin Orthop Relat Res; 2002 Dec; (405):24-38. PubMed ID: 12461353
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical and histological analysis of an HA coated, arc deposited CPTi canine hip prosthesis.
    Walenciak MT; Zimmerman MC; Harten RD; Ricci JL; Stamer DT
    J Biomed Mater Res; 1996 Aug; 31(4):465-74. PubMed ID: 8836842
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Mechanical and histological fixation of hydroxylapatite-coated pyrolytic carbon and titanium alloy implants: a report of short-term results.
    Hetherington VJ; Lord CE; Brown SA
    J Appl Biomater; 1995; 6(4):243-8. PubMed ID: 8589509
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.