21. Trial manufacture of eccentric roller type total artificial heart.
Sueshiro M; Fukunaga S; Mitsui N; Hirai S; Koura Y; Hotei H; Sueda T; Katsuhara K; Matsuura Y; Koguchi S
Artif Organs; 1997 Jul; 21(7):735-8. PubMed ID: 9212948
[TBL] [Abstract][Full Text] [Related]
22. New version of flow-transformed pulsatile total artificial heart with no electrical switching valve.
Isoyama T; Imachi K; Abe Y; Chinzei T; Imanishi K; Mabuchi K; Matsuura H; Fujimasa I
Artif Organs; 1995 Jul; 19(7):694-6. PubMed ID: 8572976
[TBL] [Abstract][Full Text] [Related]
23. Animal Experiments of the Helical Flow Total Artificial Heart.
Abe Y; Isoyama T; Saito I; Inoue Y; Ishii K; Sato M; Hara S; Yurimoto T; Li X; Murakami H; Ariyoshi K; Kawase Y; Ono T; Fukazawa K; Ishihara K
Artif Organs; 2015 Aug; 39(8):670-80. PubMed ID: 26234448
[TBL] [Abstract][Full Text] [Related]
24. An electrohydraulic total artificial heart with a separately placed actuator.
Taenaka Y; Sekii H; Tatsumi E; Nakatani T; Sasaki E; Yagura A; Akagi H; Masuzawa T; Goto M; Matsuo Y
ASAIO Trans; 1990; 36(3):M242-5. PubMed ID: 2252667
[TBL] [Abstract][Full Text] [Related]
25. Flow balance between the left and right cardiac output of an eccentric roller type total artificial heart.
Wada H; Fukunaga S; Watari M; Sakai H; Sugawara Y; Ochikubo H; Imai K; Shibamura H; Orihashi K; Sueda T; Matsuura Y
Artif Organs; 1999 Aug; 23(8):741-6. PubMed ID: 10463500
[TBL] [Abstract][Full Text] [Related]
26. In vivo test of pressure head and flow rate estimation in a continuous-flow artificial heart.
Tanaka A; Yoshizawa M; Abe K; Takeda H; Yambe T; Nitta S
Artif Organs; 2003 Jan; 27(1):99-103. PubMed ID: 12534720
[TBL] [Abstract][Full Text] [Related]
27. Appropriate control time constant in relation to characteristics of the baroreflex vascular system in 1/R control of the total artificial heart.
Mizuta S; Saito I; Isoyama T; Hara S; Yurimoto T; Li X; Murakami H; Ono T; Mabuchi K; Abe Y
J Artif Organs; 2017 Sep; 20(3):200-205. PubMed ID: 28516307
[TBL] [Abstract][Full Text] [Related]
28. Use of a total right heart bypass model for analyses of abnormal hemodynamics in total artificial heart animals, and the function and regulatory mechanisms of a natural heart.
Mabuchi K; Imachi K; Chinzei T; Abe Y; Yonezawa T; Suzukawa M; Imanishi K; Asano M; Kouno A; Ono T
ASAIO Trans; 1989; 35(3):705-8. PubMed ID: 2597570
[TBL] [Abstract][Full Text] [Related]
29. Outflow control for avoiding atrial suction in a continuous flow total artificial heart.
Olegario PS; Yoshizawa M; Tanaka A; Abe K; Takeda H; Yambe T; Nitta S
Artif Organs; 2003 Jan; 27(1):92-8. PubMed ID: 12534719
[TBL] [Abstract][Full Text] [Related]
30. Concept of left atrial pressure estimation using its pulsatile amplitude in the helical flow total artificial heart.
Wu SY; Saito I; Isoyama T; Inoue Y; Sato M; Hara S; Li XY; Yurimoto T; Murakami H; Kawase Y; Ono T; Abe Y
J Artif Organs; 2014 Dec; 17(4):301-7. PubMed ID: 25182409
[TBL] [Abstract][Full Text] [Related]
31. Total artificial heart using neural and fuzzy controller.
Lee M; Ahn JM; Min BG; Lee SY; Park CH
Artif Organs; 1996 Nov; 20(11):1220-6. PubMed ID: 8908333
[TBL] [Abstract][Full Text] [Related]
32. Hybrid Continuous-Flow Total Artificial Heart.
Fox C; Chopski S; Murad N; Allaire P; Mentzer R; Rossano J; Arabia F; Throckmorton A
Artif Organs; 2018 May; 42(5):500-509. PubMed ID: 29349805
[TBL] [Abstract][Full Text] [Related]
33. Development and evaluation of components for a totally implantable artificial heart system.
Taenaka Y; Masuzawa T; Tatsumi F; Anai H; Toda K; Akagi H; Nakatani T; Baba Y; Fya K; Wakisaka Y
ASAIO J; 1994; 40(3):M314-8. PubMed ID: 8555531
[TBL] [Abstract][Full Text] [Related]
34. The helical flow total artificial heart: implantation in goats.
Abe Y; Ishii K; Isoyama T; Saito I; Inoue Y; Sato M; Hara S; Hosoda K; Ariyoshi K; Nakagawa H; Ono T; Fukazawa K; Ishihara K; Imachi K
Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():2720-3. PubMed ID: 24110289
[TBL] [Abstract][Full Text] [Related]
35. Effect of pressure-flow relationship of centrifugal pump on in vivo hemodynamics: a consideration for design.
Tagusari O; Yamazaki K; Litwak P; Antaki JF; Watach M; Gordon LM; Kono K; Mori T; Koyanagi H; Griffith BP; Kormos RL
Artif Organs; 1998 May; 22(5):399-404. PubMed ID: 9609348
[TBL] [Abstract][Full Text] [Related]
36. Chronic in vivo evaluation of a portable electrohydraulic ventricular assist system with a linear actuator.
Yagura A; Taenaka Y; Takano H; Nakatani T; Tatsumi E; Sekii H; Sasaki E; Akagi H; Goto M; Akutsu T
ASAIO Trans; 1990; 36(3):M284-7. PubMed ID: 2252679
[TBL] [Abstract][Full Text] [Related]
37. System overview of the fully implantable destination therapy--ReinHeart-total artificial heart.
Pelletier B; Spiliopoulos S; Finocchiaro T; Graef F; Kuipers K; Laumen M; Guersoy D; Steinseifer U; Koerfer R; Tenderich G
Eur J Cardiothorac Surg; 2015 Jan; 47(1):80-6. PubMed ID: 25234093
[TBL] [Abstract][Full Text] [Related]
38. Development of total artificial heart with economical and durability advantages.
Yambe T; Fukutome A; Kobayashi S; Nanka S; Yoshizawa M; Tabayashi K; Takeda H; Nitta S
Int J Artif Organs; 1998 May; 21(5):279-84. PubMed ID: 9684910
[TBL] [Abstract][Full Text] [Related]
39. Analysis of hemodynamic response with 1/R control on biventricular bypass goat.
Abe Y; Chinzei T; Isoyama T; Mochizuki S; Saito I; Karita T; Ono T; Kouno A; Baba K; Imachi K
Artif Organs; 2000 Apr; 24(4):312-5. PubMed ID: 10816207
[TBL] [Abstract][Full Text] [Related]
40. Component engineering for an implantable system.
Wang Q; Yambe T; Shiraishi Y; Esashi M; Haga Y; Yoshizawa M; Sato F; Matsuki H; Imachi K; Abe Y; Sasada H; Nitta S
Artif Organs; 2004 Oct; 28(10):869-73. PubMed ID: 15384991
[TBL] [Abstract][Full Text] [Related]