These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
163 related articles for article (PubMed ID: 9212940)
1. Hemolysis test of disposable type vibrating flow pump. Kobayashi S; Nitta S; Yambe T; Sonobe T; Naganuma S; Hashimoto H Artif Organs; 1997 Jul; 21(7):691-3. PubMed ID: 9212940 [TBL] [Abstract][Full Text] [Related]
2. Development of vibrating flow pump for left ventricular assist circulation. Kobayashi S; Nitta S; Yambe T; Sonobe T; Nannka S; Shizuka K; Fkuju T; Hashimoto H Int J Artif Organs; 1998 Apr; 21(4):225-8. PubMed ID: 9649064 [TBL] [Abstract][Full Text] [Related]
3. Total vascular resistance and blood flow frequency during left ventricular assistance using a vibrating flow pump. Kobayashi S; Owada N; Yambe T; Nitta S; Fukuju T; Hongoh T; Hashimoto H Artif Organs; 1999 Aug; 23(8):732-5. PubMed ID: 10463498 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of hemolysis in a pulsatile assist device for centrifugal pump. Iwaya F; Igari T; Hoshino S; Hikichi H Artif Organs; 1997 Jul; 21(7):700-3. PubMed ID: 9212942 [TBL] [Abstract][Full Text] [Related]
5. Gas exchange efficiency of a membrane oxygenator with use of a vibrating flow pump. Naganuma S; Nitta S; Yambe T; Kobayashi S; Tanaka M; Hashimoto H Artif Organs; 1995 Jul; 19(7):747-9. PubMed ID: 8572988 [TBL] [Abstract][Full Text] [Related]
6. Experimental study of physiological advantages of assist circulation using oscillated blood flow. Kobayashi S; Nitta S; Yambe T; Naganuma S; Hashimoto H; Fukuju T; Tabayashi K Artif Organs; 1995 Jul; 19(7):704-7. PubMed ID: 8572979 [TBL] [Abstract][Full Text] [Related]
7. Computational flow visualization in vibrating flow pump type artificial heart by unstructured grid. Kato T; Kawano S; Nakahashi K; Yambe T; Nitta S; Hashimoto H Artif Organs; 2003 Jan; 27(1):41-8. PubMed ID: 12534712 [TBL] [Abstract][Full Text] [Related]
8. Chronic animal experiment with magnetically suspended centrifugal pump. Yamada T; Nishimura K; Park CH; Kono S; Yuasa S; Tsukiya T; Akamatsu T; Matsuda K; Ban T Artif Organs; 1997 Jul; 21(7):635-8. PubMed ID: 9212930 [TBL] [Abstract][Full Text] [Related]
9. Recent progress on the vibrating flow pump as a totally implantable ventricular assist device. Yambe T; Kobayashi SI; Yoshizawa M; Tanaka A; Matsuki H; Sato F; Tabayashi K; Nitta SI Artif Organs; 2001 Sep; 25(9):688-91. PubMed ID: 11722343 [TBL] [Abstract][Full Text] [Related]
10. Peripheral vascular resistances during total left heart bypass with an oscillated blood flow. Yambe T; Kawano S; Nanka S; Kobayashi S; Tanaka A; Owada N; Yoshizawa M; Abe K; Tabayashi K; Takeda H; Hashimoto H; Nitta S Artif Organs; 1999 Aug; 23(8):747-50. PubMed ID: 10463501 [TBL] [Abstract][Full Text] [Related]
11. A new blood pump for cardiopulmonary bypass: the HiFlow centrifugal pump. Göbel C; Eilers R; Reul H; Schwindke P; Jörger M; Rau G Artif Organs; 1997 Jul; 21(7):841-5. PubMed ID: 9212970 [TBL] [Abstract][Full Text] [Related]
12. Comparison of hemolytic properties of different shapes of occlusion of blood sac in occlusive-type pulsatile blood pump. Choi H; Min BG; Won YS Artif Organs; 2008 Feb; 32(2):160-6. PubMed ID: 18269354 [TBL] [Abstract][Full Text] [Related]
13. The effects of pressure and flow on hemolysis caused by Bio-Medicus centrifugal pumps and roller pumps. Guidelines for choosing a blood pump. Tamari Y; Lee-Sensiba K; Leonard EF; Parnell V; Tortolani AJ J Thorac Cardiovasc Surg; 1993 Dec; 106(6):997-1007. PubMed ID: 8246582 [TBL] [Abstract][Full Text] [Related]
14. Chaotic dynamics in circulation with Tohoku University vibrating flow pump. Nitta S; Yambe T; Kobayashi S; Hashimoto H; Yoshizawa M; Mastuki H; Tabayashi K; Takeda H Artif Organs; 1999 Jan; 23(1):119-23. PubMed ID: 9950190 [TBL] [Abstract][Full Text] [Related]
15. The newly designed univalved artificial heart. Nitta S; Hashimoto H; Sonobe T; Katahira Y; Yambe T; Naganuma S; Tanaka M; Sato N; Miura M; Mohri H ASAIO Trans; 1991; 37(3):M240-1. PubMed ID: 1751128 [TBL] [Abstract][Full Text] [Related]
16. Development of design methods for a centrifugal blood pump with a fluid dynamic approach: results in hemolysis tests. Masuzawa T; Tsukiya T; Endo S; Tatsumi E; Taenaka Y; Takano H; Yamane T; Nishida M; Asztalos B; Miyazoe Y; Ito K; Sawairi T; Konishi Y Artif Organs; 1999 Aug; 23(8):757-61. PubMed ID: 10463503 [TBL] [Abstract][Full Text] [Related]
17. In vivo assessment of a new method of pulsatile perfusion based on a centrifugal pump. Herreros J; Ubilla M; Berjano EJ; Vila-Nuñez JE; Páramo JA; Sola J; Mercé S Artif Organs; 2010 Feb; 34(2):140-6. PubMed ID: 20085571 [TBL] [Abstract][Full Text] [Related]
18. Left heart bypass using the oscillated blood flow with totally implantable vibrating flow pump. Yambe T; Owada N; Kobayashi S; Sonobe T; Naganuma S; Nanka S; Hashimoto H; Yoshizawa M; Tabayashi K; Takayasu H; Takeda H; Nitta S Artif Organs; 1998 May; 22(5):426-9. PubMed ID: 9609353 [TBL] [Abstract][Full Text] [Related]
19. Totally implantable ventricular assist system that can increase brain blood flow. Yambe T; Owada N; Kobayashi SI; Tanaka A; Yoshizawa M; Abe KI; Tabayashi K; Takeda H; Hashimoto H; Nitta SI Artif Organs; 2000 Aug; 24(8):644-7. PubMed ID: 10971254 [TBL] [Abstract][Full Text] [Related]
20. The effect of the impeller-driver magnetic coupling distance on hemolysis in a compact centrifugal pump. Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y Artif Organs; 1996 Mar; 20(3):252-7. PubMed ID: 8694696 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]