132 related articles for article (PubMed ID: 9212945)
21. Recent advances in the gyro centrifugal ventricular assist device.
Nakazawa T; Benkowski R; Makinouchi K; Takami Y; Ohtsubo S; Glueck J; Kawahito K; Sueoka A; Schmallegger H; Schima H; Wolner E; Nosé Y
ASAIO J; 1998; 44(1):94-7. PubMed ID: 9466508
[TBL] [Abstract][Full Text] [Related]
22. Evaluation of the wear of the pivot bearing in the Gyro C1E3 pump.
Makinouchi K; Nakazawa T; Takami Y; Takatani S; Nosé Y
Artif Organs; 1996 Jun; 20(6):523-8. PubMed ID: 8817949
[TBL] [Abstract][Full Text] [Related]
23. Safety margin of magnetic coupling distance in decoupling of a pivot bearing-supported Gyro centrifugal pump (C1E3).
Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1996 Jul; 20(7):817-9. PubMed ID: 8828776
[TBL] [Abstract][Full Text] [Related]
24. Optical Dynamic Analysis of Thrombus Inside a Centrifugal Blood Pump During Extracorporeal Mechanical Circulatory Support in a Porcine Model.
Fujiwara T; Sakota D; Ohuchi K; Endo S; Tahara T; Murashige T; Kosaka R; Oi K; Mizuno T; Maruyama O; Arai H
Artif Organs; 2017 Oct; 41(10):893-903. PubMed ID: 28321882
[TBL] [Abstract][Full Text] [Related]
25. Prevention of thrombus formation in blood pump by mechanical circular orbital excitation of impeller in magnetically levitated centrifugal pump.
Hatakenaka K; Hijikata W; Fujiwara T; Ohuchi K; Inoue Y
Artif Organs; 2023 Feb; 47(2):425-431. PubMed ID: 36305737
[TBL] [Abstract][Full Text] [Related]
26. In vitro thrombogenic evaluation of centrifugal pumps.
Tayama E; Ohtsubo S; Nakazawa T; Takami Y; Niimi Y; Makinouchi K; Glueck J; Nosé Y
Artif Organs; 1997 May; 21(5):418-20. PubMed ID: 9129776
[TBL] [Abstract][Full Text] [Related]
27. Hemolytic effects of surface roughness of a pump housing in a centrifugal blood pump.
Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1997 May; 21(5):428-32. PubMed ID: 9129778
[TBL] [Abstract][Full Text] [Related]
28. Development of the NEDO implantable ventricular assist device with Gyro centrifugal pump.
Yoshikawa M; Nonaka K; Linneweber J; Kawahito S; Ohtsuka G; Nakata K; Takano T; Schulte-Eistrup S; Glueck J; Schima H; Wolner E; Nosé Y
Artif Organs; 2000 Jun; 24(6):459-67. PubMed ID: 10886066
[TBL] [Abstract][Full Text] [Related]
29. Feasibility of the optical imaging of thrombus formation in a rotary blood pump by near-infrared light.
Sakota D; Murashige T; Kosaka R; Nishida M; Maruyama O
Artif Organs; 2014 Sep; 38(9):733-40. PubMed ID: 25234757
[TBL] [Abstract][Full Text] [Related]
30. Hemolytic effect of the secondary vane incorporated into the back side of the impeller.
Ohara Y; Murase M; Nosé Y
Artif Organs; 1997 Jul; 21(7):694-9. PubMed ID: 9212941
[TBL] [Abstract][Full Text] [Related]
31. Ex vivo evaluation of the NASA/DeBakey axial flow ventricular assist device. Results of a 2 week screening test.
Kawahito K; Benkowski R; Otsubo S; Rosenbaum B; Moreland R; Noon GP; Nosé Y; Debakey ME
ASAIO J; 1996; 42(5):M754-7. PubMed ID: 8944983
[TBL] [Abstract][Full Text] [Related]
32. In vitro investigation of thrombogenesis in rotary blood pumps.
Schima H; Siegl H; Mohammad SF; Huber L; Müller MR; Losert U; Thoma H; Wolner E
Artif Organs; 1993 Jul; 17(7):605-8. PubMed ID: 8338434
[TBL] [Abstract][Full Text] [Related]
33. Detection of thrombosis in a magnetically levitated blood pump by vibrational excitation of the impeller.
Hijikata W; Maruyama T; Murashige T; Sakota D; Maruyama O
Artif Organs; 2020 Jun; 44(6):594-603. PubMed ID: 31904107
[TBL] [Abstract][Full Text] [Related]
34. Characteristics of a blood pump combining the centrifugal and axial pumping principles: the spiral pump.
Andrade A; Biscegli J; Dinkhuysen J; Sousa JE; Ohashi Y; Hemmings S; Glueck J; Kawahito K; Nosé Y
Artif Organs; 1996 Jun; 20(6):605-12. PubMed ID: 8817964
[TBL] [Abstract][Full Text] [Related]
35. Real-Time Observation of Thrombus Growth Process in an Impeller of a Hydrodynamically Levitated Centrifugal Blood Pump by Near-Infrared Hyperspectral Imaging.
Sakota D; Murashige T; Kosaka R; Fujiwara T; Nishida M; Maruyama O
Artif Organs; 2015 Aug; 39(8):714-9. PubMed ID: 26234451
[TBL] [Abstract][Full Text] [Related]
36. A magnetically suspended centrifugal pump. In vitro and in vivo assessment.
Park CH; Nishimura K; Yamada T; Mizuhara H; Akamatsu T; Tsukiya T; Matsuda K; Ban T
ASAIO J; 1995; 41(3):M345-50. PubMed ID: 8573822
[TBL] [Abstract][Full Text] [Related]
37. Eccentric inlet port of the pivot bearing supported Gyro centrifugal pump.
Takami Y; Andrade A; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1997 Apr; 21(4):312-7. PubMed ID: 9096804
[TBL] [Abstract][Full Text] [Related]
38. Development and evaluation of antithrombogenic centrifugal pump: the Baylor C-Gyro Pump Eccentric Inlet Port Model.
Ohara Y; Makinouchi K; Glueck J; Sutherland B; Shimono T; Naito K; Tasai K; Orime Y; Takatani S; Nosé Y
Artif Organs; 1994 Sep; 18(9):673-9. PubMed ID: 7998885
[TBL] [Abstract][Full Text] [Related]
39. A new blood pump for cardiopulmonary bypass: the HiFlow centrifugal pump.
Göbel C; Eilers R; Reul H; Schwindke P; Jörger M; Rau G
Artif Organs; 1997 Jul; 21(7):841-5. PubMed ID: 9212970
[TBL] [Abstract][Full Text] [Related]
40. The simple in vitro thrombogenic test: modified methods for same priming pumps.
Tayama E; Ohtsubo S; Nakazawa T; Takami Y; Niimi Y; Makinouchi K; Glueck JA; Nosé Y
Artif Organs; 1997 Dec; 21(12):1305-8. PubMed ID: 9423986
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]