171 related articles for article (PubMed ID: 9212958)
1. Comparison of the Gyro C1E3 and BioMedicus centrifugal pump performances during cardiopulmonary bypass.
Nakazawa T; Takami Y; Makinouchi K; Gay J; Taylor D; Ueyama K; Ohashi Y; Kawahito K; Tayama E; Glueck J; Nosé Y
Artif Organs; 1997 Jul; 21(7):782-5. PubMed ID: 9212958
[TBL] [Abstract][Full Text] [Related]
2. Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications.
Takami Y; Makinouchi K; Nakazawa T; Benkowski R; Glueck J; Ohara Y; Nosé Y
Artif Organs; 1996 Sep; 20(9):1042-9. PubMed ID: 8864026
[TBL] [Abstract][Full Text] [Related]
3. Modification of a pivot bearing system on a compact centrifugal pump.
Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y
Artif Organs; 1996 Mar; 20(3):258-63. PubMed ID: 8694697
[TBL] [Abstract][Full Text] [Related]
4. The effect of the impeller-driver magnetic coupling distance on hemolysis in a compact centrifugal pump.
Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y
Artif Organs; 1996 Mar; 20(3):252-7. PubMed ID: 8694696
[TBL] [Abstract][Full Text] [Related]
5. Clinical evaluation of the Gyro Pump C1E3 as a cardiopulmonary bypass pump.
Orime Y; Shiono M; Yagi S; Yamamoto T; Okumura H; Kimura S; Hata M; Sezai A; Kashiwazaki S; Choh S; Negishi N; Sezai Y; Matsui T; Suzuki M
ASAIO J; 2000; 46(1):128-33. PubMed ID: 10667731
[TBL] [Abstract][Full Text] [Related]
6. Effect of surface roughness on hemolysis in a pivot bearing supported Gyro centrifugal pump (C1E3).
Takami Y; Makinouchi K; Nakazawa T; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1996 Nov; 20(11):1155-61. PubMed ID: 8908324
[TBL] [Abstract][Full Text] [Related]
7. Hydraulic assessment of the floating impeller phenomena in a centrifugal pump.
Nakazawa T; Takami Y; Makinouchi K; Benkowski R; Glueck J; Damm G; Nosé Y
Artif Organs; 1997 Jan; 21(1):78-82. PubMed ID: 9012911
[TBL] [Abstract][Full Text] [Related]
8. A pivot bearing-supported centrifugal pump for a long-term assist heart.
Nakazawa T; Ohara Y; Benkowski R; Makinouchi K; Takami Y; Ohtsubo S; Kawahito K; Tasai K; Glueck J; Noon GP; Sueoka A; Schmallegger H; Schima H; Wolner E; Nosé Y
Int J Artif Organs; 1997 Apr; 20(4):222-8. PubMed ID: 9195240
[TBL] [Abstract][Full Text] [Related]
9. Preclinical evaluation of the Kyocera Gyro centrifugal blood pump for cardiopulmonary bypass.
Takami Y; Ohara Y; Otsuka G; Nakazawa T; Nosé Y
Perfusion; 1997 Sep; 12(5):335-41. PubMed ID: 9300479
[TBL] [Abstract][Full Text] [Related]
10. The hemolysis test of the Gyro C1E3 pump in pulsatile mode.
Tayama E; Nakazawa T; Takami Y; Makinouchi K; Ohtsubo S; Ohashi Y; Andrade AJ; Glueck J; Mueller J; Nosé Y
Artif Organs; 1997 Jul; 21(7):675-9. PubMed ID: 9304391
[TBL] [Abstract][Full Text] [Related]
11. Material of the double pivot bearing system in the Gyro C1E3 centrifugal pump.
Takami Y; Nakazawa T; Makinouchi K; Benkowski R; Glueck J; Nosé Y
Artif Organs; 1997 Feb; 21(2):143-7. PubMed ID: 9028497
[TBL] [Abstract][Full Text] [Related]
12. Long-term ex vivo bovine experiments with the Gyro C1E3 centrifugal blood pump.
Kawahito S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Kawamura M; Glueck J; Fujisawa A; Makinouchi K; Nosé Y
ASAIO J; 2003; 49(1):112-6. PubMed ID: 12558317
[TBL] [Abstract][Full Text] [Related]
13. Hemolytic effect of the secondary vane incorporated into the back side of the impeller.
Ohara Y; Murase M; Nosé Y
Artif Organs; 1997 Jul; 21(7):694-9. PubMed ID: 9212941
[TBL] [Abstract][Full Text] [Related]
14. Eccentric inlet port of the pivot bearing supported Gyro centrifugal pump.
Takami Y; Andrade A; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1997 Apr; 21(4):312-7. PubMed ID: 9096804
[TBL] [Abstract][Full Text] [Related]
15. Cardiopulmonary bypass with Nikkiso and BioMedicus centrifugal pumps.
Orime Y; Takatani S; Sasaki T; Aizawa T; Ohara Y; Naito K; Glueck J; Noon GP; Nosé Y; DeBakey ME
Artif Organs; 1994 Jan; 18(1):11-6. PubMed ID: 8141652
[TBL] [Abstract][Full Text] [Related]
16. Safety margin of magnetic coupling distance in decoupling of a pivot bearing-supported Gyro centrifugal pump (C1E3).
Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
Artif Organs; 1996 Jul; 20(7):817-9. PubMed ID: 8828776
[TBL] [Abstract][Full Text] [Related]
17. An ultimate, compact, seal-less centrifugal ventricular assist device: Baylor C-Gyro pump.
Ohara Y; Makinouchi K; Orime Y; Tasai K; Naito K; Mizuguchi K; Shimono T; Damm G; Glueck J; Takatani S
Artif Organs; 1994 Jan; 18(1):17-24. PubMed ID: 8141653
[TBL] [Abstract][Full Text] [Related]
18. Clinical study of totally roller pumpless cardiopulmonary bypass system.
Murakami F; Usui A; Hiroura M; Kawamura M; Koyama T; Murase M
Artif Organs; 1997 Jul; 21(7):803-7. PubMed ID: 9212963
[TBL] [Abstract][Full Text] [Related]
19. Platelet activation in the gyro C1E3 centrifugal pump: comparison with the terumo capiox and the Nikkiso HPM-15.
Kawahito K; Adachi H; Ino T
Artif Organs; 2000 Nov; 24(11):889-92. PubMed ID: 11119077
[TBL] [Abstract][Full Text] [Related]
20. Evaluation of the wear of the pivot bearing in the Gyro C1E3 pump.
Makinouchi K; Nakazawa T; Takami Y; Takatani S; Nosé Y
Artif Organs; 1996 Jun; 20(6):523-8. PubMed ID: 8817949
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]