BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 9212958)

  • 1. Comparison of the Gyro C1E3 and BioMedicus centrifugal pump performances during cardiopulmonary bypass.
    Nakazawa T; Takami Y; Makinouchi K; Gay J; Taylor D; Ueyama K; Ohashi Y; Kawahito K; Tayama E; Glueck J; Nosé Y
    Artif Organs; 1997 Jul; 21(7):782-5. PubMed ID: 9212958
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemolytic characteristics of a pivot bearing supported Gyro centrifugal pump (C1E3) simulating various clinical applications.
    Takami Y; Makinouchi K; Nakazawa T; Benkowski R; Glueck J; Ohara Y; Nosé Y
    Artif Organs; 1996 Sep; 20(9):1042-9. PubMed ID: 8864026
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modification of a pivot bearing system on a compact centrifugal pump.
    Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y
    Artif Organs; 1996 Mar; 20(3):258-63. PubMed ID: 8694697
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of the impeller-driver magnetic coupling distance on hemolysis in a compact centrifugal pump.
    Nakazawa T; Makinouchi K; Takami Y; Glueck J; Takatani S; Nosé Y
    Artif Organs; 1996 Mar; 20(3):252-7. PubMed ID: 8694696
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Clinical evaluation of the Gyro Pump C1E3 as a cardiopulmonary bypass pump.
    Orime Y; Shiono M; Yagi S; Yamamoto T; Okumura H; Kimura S; Hata M; Sezai A; Kashiwazaki S; Choh S; Negishi N; Sezai Y; Matsui T; Suzuki M
    ASAIO J; 2000; 46(1):128-33. PubMed ID: 10667731
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of surface roughness on hemolysis in a pivot bearing supported Gyro centrifugal pump (C1E3).
    Takami Y; Makinouchi K; Nakazawa T; Glueck J; Benkowski R; Nosé Y
    Artif Organs; 1996 Nov; 20(11):1155-61. PubMed ID: 8908324
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hydraulic assessment of the floating impeller phenomena in a centrifugal pump.
    Nakazawa T; Takami Y; Makinouchi K; Benkowski R; Glueck J; Damm G; Nosé Y
    Artif Organs; 1997 Jan; 21(1):78-82. PubMed ID: 9012911
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A pivot bearing-supported centrifugal pump for a long-term assist heart.
    Nakazawa T; Ohara Y; Benkowski R; Makinouchi K; Takami Y; Ohtsubo S; Kawahito K; Tasai K; Glueck J; Noon GP; Sueoka A; Schmallegger H; Schima H; Wolner E; Nosé Y
    Int J Artif Organs; 1997 Apr; 20(4):222-8. PubMed ID: 9195240
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preclinical evaluation of the Kyocera Gyro centrifugal blood pump for cardiopulmonary bypass.
    Takami Y; Ohara Y; Otsuka G; Nakazawa T; Nosé Y
    Perfusion; 1997 Sep; 12(5):335-41. PubMed ID: 9300479
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The hemolysis test of the Gyro C1E3 pump in pulsatile mode.
    Tayama E; Nakazawa T; Takami Y; Makinouchi K; Ohtsubo S; Ohashi Y; Andrade AJ; Glueck J; Mueller J; Nosé Y
    Artif Organs; 1997 Jul; 21(7):675-9. PubMed ID: 9304391
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Material of the double pivot bearing system in the Gyro C1E3 centrifugal pump.
    Takami Y; Nakazawa T; Makinouchi K; Benkowski R; Glueck J; Nosé Y
    Artif Organs; 1997 Feb; 21(2):143-7. PubMed ID: 9028497
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term ex vivo bovine experiments with the Gyro C1E3 centrifugal blood pump.
    Kawahito S; Maeda T; Motomura T; Takano T; Nonaka K; Linneweber J; Ichikawa S; Kawamura M; Glueck J; Fujisawa A; Makinouchi K; Nosé Y
    ASAIO J; 2003; 49(1):112-6. PubMed ID: 12558317
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Hemolytic effect of the secondary vane incorporated into the back side of the impeller.
    Ohara Y; Murase M; Nosé Y
    Artif Organs; 1997 Jul; 21(7):694-9. PubMed ID: 9212941
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Eccentric inlet port of the pivot bearing supported Gyro centrifugal pump.
    Takami Y; Andrade A; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
    Artif Organs; 1997 Apr; 21(4):312-7. PubMed ID: 9096804
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardiopulmonary bypass with Nikkiso and BioMedicus centrifugal pumps.
    Orime Y; Takatani S; Sasaki T; Aizawa T; Ohara Y; Naito K; Glueck J; Noon GP; Nosé Y; DeBakey ME
    Artif Organs; 1994 Jan; 18(1):11-6. PubMed ID: 8141652
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Safety margin of magnetic coupling distance in decoupling of a pivot bearing-supported Gyro centrifugal pump (C1E3).
    Takami Y; Nakazawa T; Makinouchi K; Glueck J; Benkowski R; Nosé Y
    Artif Organs; 1996 Jul; 20(7):817-9. PubMed ID: 8828776
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An ultimate, compact, seal-less centrifugal ventricular assist device: Baylor C-Gyro pump.
    Ohara Y; Makinouchi K; Orime Y; Tasai K; Naito K; Mizuguchi K; Shimono T; Damm G; Glueck J; Takatani S
    Artif Organs; 1994 Jan; 18(1):17-24. PubMed ID: 8141653
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Clinical study of totally roller pumpless cardiopulmonary bypass system.
    Murakami F; Usui A; Hiroura M; Kawamura M; Koyama T; Murase M
    Artif Organs; 1997 Jul; 21(7):803-7. PubMed ID: 9212963
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Platelet activation in the gyro C1E3 centrifugal pump: comparison with the terumo capiox and the Nikkiso HPM-15.
    Kawahito K; Adachi H; Ino T
    Artif Organs; 2000 Nov; 24(11):889-92. PubMed ID: 11119077
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the wear of the pivot bearing in the Gyro C1E3 pump.
    Makinouchi K; Nakazawa T; Takami Y; Takatani S; Nosé Y
    Artif Organs; 1996 Jun; 20(6):523-8. PubMed ID: 8817949
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.