BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

144 related articles for article (PubMed ID: 9213026)

  • 1. Local delivery of heparin to balloon angioplasty sites with a new angiotherapy catheter: pharmacokinetics and effect on platelet deposition in the porcine model.
    Fram DB; Mitchel JF; Azrin MA; Chow MS; Waters DD; McKay RG
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):275-86. PubMed ID: 9213026
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Localized delivery of heparin to angioplasty sites with iontophoresis.
    Mitchel JF; Azrin MA; Fram DB; Bow LM; McKay RG
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):315-23. PubMed ID: 9213031
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Local urokinase delivery with the Channel balloon: device safety, pharmacokinetics of intracoronary drug delivery, and efficacy of thrombolysis.
    Mitchel JF; Barry JJ; Bow L; Alberghini TA; Abbas SA; McKay RG
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):254-60. PubMed ID: 9213023
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Decreased platelet deposition and smooth muscle cell proliferation after intramural heparin delivery with hydrogel-coated balloons.
    Azrin MA; Mitchel JF; Fram DB; Pedersen CA; Cartun RW; Barry JJ; Bow LM; Waters DD; McKay RG
    Circulation; 1994 Jul; 90(1):433-41. PubMed ID: 8026030
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Infiltrator Angioplasty Balloon Catheter: a device for combined angioplasty and intramural site-specific treatment.
    Barath P; Popov A; Dillehay GL; Matos G; McKiernan T
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):333-41. PubMed ID: 9213033
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Catheter-based local thrombolysis with urokinase: comparative efficacy of intraluminal clot lysis with conventional urokinase infusion techniques in an in vivo porcine thrombus model.
    Mitchel JF; Shwedick M; Alberghini TA; Knibbs D; McKay RG
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):293-302. PubMed ID: 9213028
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Enhanced local intracoronary delivery of heparin with the Infiltrator catheter: a comparative study.
    Mitchel JF; Fram DB; Gillam LD; Giri S; Waters DD; Kiernan FJ
    J Invasive Cardiol; 1999 Aug; 11(8):463-70. PubMed ID: 10745576
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intramural delivery of agent via a novel drug-delivery sleeve. Histological and functional evaluation.
    Moura A; Lam JY; Hébert D; Kermode JR; Grant GW; Robitaille D; Klein EJ; Yock PG; Simpson JB; Kaplan AV
    Circulation; 1995 Oct; 92(8):2299-305. PubMed ID: 7554215
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enhanced intracoronary thrombolysis with urokinase using a novel, local drug delivery system. In vitro, in vivo, and clinical studies.
    Mitchel JF; Fram DB; Palme DF; Foster R; Hirst JA; Azrin MA; Bow LM; Eldin AM; Waters DD; McKay RG
    Circulation; 1995 Feb; 91(3):785-93. PubMed ID: 7828307
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Local delivery of antithrombin inhibits platelet deposition after balloon injury in a porcine coronary model.
    Scherstén F; Björnheden T; Emanuelsson H; Wiklund O; Grip L
    Coron Artery Dis; 1998; 9(12):823-9. PubMed ID: 9894927
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Intramural drug delivery by direct injection within the arterial wall: first clinical experience with a novel intracoronary delivery-infiltrator system.
    Pavlides GS; Barath P; Maginas A; Vasilikos V; Cokkinos DV; O'Neill WW
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):287-92. PubMed ID: 9213027
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Local delivery of c-myb antisense oligonucleotides during balloon angioplasty.
    Azrin MA; Mitchel JF; Bow LM; Pedersen CA; Cartun RW; Aretz TH; Waters DD; McKay RG
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):232-40. PubMed ID: 9213020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inhibition of platelet deposition and lysis of intracoronary thrombus during balloon angioplasty using urokinase-coated hydrogel balloons.
    Mitchel JF; Azrin MA; Fram DB; Hong MK; Wong SC; Barry JJ; Bow LM; Curley TM; Kiernan FJ; Waters DD
    Circulation; 1994 Oct; 90(4):1979-88. PubMed ID: 7923688
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Local delivery of r-hirudin by a double-balloon perfusion catheter prevents mural thrombosis and minimizes platelet deposition after angioplasty.
    Meyer BJ; Fernández-Ortiz A; Mailhac A; Falk E; Badimon L; Michael AD; Chesebro JH; Fuster V; Badimon JJ
    Circulation; 1994 Nov; 90(5):2474-80. PubMed ID: 7955205
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Time course of smooth muscle cell proliferation after local drug delivery of low-molecular-weight heparin using a porous balloon catheter.
    Oberhoff M; Herdeg C; Baumbach A; Shamet K; Kranzhöfer A; Weingärtner O; Rübsamen K; Kluge M; Karsch KR
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):268-74. PubMed ID: 9213025
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of low-molecular-weight heparin delivery with the Dispatch catheter following balloon angioplasty in the rabbit iliac artery.
    Baumbach A; Oberhoff M; Bohnet A; Miljak T; Herdeg C; Horch B; Blessing E; Kunert W; Haase KK; Karsch KR
    Cathet Cardiovasc Diagn; 1997 Jul; 41(3):303-7. PubMed ID: 9213029
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Porous balloon delivery of low molecular weight heparin in the dog coronary artery.
    Baumbach A; Oberhoff M; Rübsamen K; Jochims K; Herdeg C; Kranzhöfer A; Safer A; Karsch KR
    Eur Heart J; 1996 Oct; 17(10):1538-45. PubMed ID: 8909911
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Inhibition of platelet-dependent thrombosis by local delivery of heparin with a hydrogel-coated balloon.
    Nunes GL; Thomas CN; Hanson SR; Barry JJ; King SB; Scott NA
    Circulation; 1995 Oct; 92(7):1697-700. PubMed ID: 7671350
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Quantitative evaluation of local drug delivery using the InfusaSleeve catheter.
    Gottsauner-Wolf M; Jang Y; Penn MS; Kaplan A; Ellis SG; Chisolm GM; Topol EJ; Lincoff AM
    Cathet Cardiovasc Diagn; 1997 Sep; 42(1):102-8. PubMed ID: 9286553
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Feasibility and drug delivery efficiency of a new balloon angioplasty catheter capable of performing simultaneous local drug delivery.
    Hong MK; Wong SC; Farb A; Mehlman MD; Virmani R; Barry JJ; Leon MB
    Coron Artery Dis; 1993 Nov; 4(11):1023-7. PubMed ID: 8173708
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.