364 related articles for article (PubMed ID: 9213728)
1. [Initial experience with ventilation-perfusion scintigraphy in patients with a suspected pulmonary embolism].
Kovacić K; Susković T; Kusić Z; Lacić M
Lijec Vjesn; 1997 Jan; 119(1):27-31. PubMed ID: 9213728
[TBL] [Abstract][Full Text] [Related]
2. DTPA aerosol in ventilation/perfusion scintigraphy for diagnosing pulmonary embolism.
Trujillo NP; Pratt JP; Talusani S; Quaife RA; Kumpe D; Lear JL
J Nucl Med; 1997 Nov; 38(11):1781-3. PubMed ID: 9374354
[TBL] [Abstract][Full Text] [Related]
3. Krypton-81m ventilation and technetium-99m macroaggregated albumin perfusion scintigraphy for detection of pulmonary embolism: the first experience in Taiwan.
Cherng SC; Yang SP; Wang YF; Jen TK; Huang WS; Lo AR
Zhonghua Yi Xue Za Zhi (Taipei); 2000 Dec; 63(12):876-84. PubMed ID: 11195138
[TBL] [Abstract][Full Text] [Related]
4. Diagnosis of pulmonary embolus using ventilation/perfusion lung scintigraphy: more than 0.5 segment of ventilation/perfusion mismatch is sufficient.
Howarth DM; Booker JA; Voutnis DD
Intern Med J; 2006 May; 36(5):281-8. PubMed ID: 16650192
[TBL] [Abstract][Full Text] [Related]
5. 99mTc technegas ventilation and perfusion lung scintigraphy for the diagnosis of pulmonary embolus.
Howarth DM; Lan L; Thomas PA; Allen LW
J Nucl Med; 1999 Apr; 40(4):579-84. PubMed ID: 10210216
[TBL] [Abstract][Full Text] [Related]
6. Diagnostic evaluation of planar and tomographic ventilation/perfusion lung images in patients with suspected pulmonary emboli.
Bajc M; Olsson CG; Olsson B; Palmer J; Jonson B
Clin Physiol Funct Imaging; 2004 Sep; 24(5):249-56. PubMed ID: 15383080
[TBL] [Abstract][Full Text] [Related]
7. [Value of ventilation scintigraphy in the diagnosis of pulmonary thromboembolism].
Ruiz Hernández G; Maya Martínez M; Carrión Valero F; Castillo Pallarés FJ; Mateo Navarro A; Marín Pardo J
An Med Interna; 1999 Aug; 16(8):389-93. PubMed ID: 10507164
[TBL] [Abstract][Full Text] [Related]
8. Clinical experience with technetium-99m DTPA aerosol with perfusion scintigraphy in suspected pulmonary embolism.
Selby JB; Gardner JJ
Clin Nucl Med; 1987 Jan; 12(1):1-5. PubMed ID: 3545607
[TBL] [Abstract][Full Text] [Related]
9. Utility of Tc-99m DTPA aerosol inhalation scans following perfusion lung scans in the diagnosis of pulmonary embolism.
Selby JB; Callcott F; Gordon L; Gardner J
Clin Nucl Med; 1990 Mar; 15(3):143-9. PubMed ID: 2180607
[TBL] [Abstract][Full Text] [Related]
10. Diagnosis of pulmonary embolism with spiral CT as a second procedure following scintigraphy.
van Strijen MJ; de Monyé W; Kieft GJ; Pattynama PM; Huisman MV; Smith SJ; Bloem JL
Eur Radiol; 2003 Jul; 13(7):1501-7. PubMed ID: 12835960
[TBL] [Abstract][Full Text] [Related]
11. Clinical outcomes of patients with suspected pulmonary embolism and low-probability aerosol-perfusion scintigrams.
Smith R; Maher JM; Miller RI; Alderson PO
Radiology; 1987 Sep; 164(3):731-3. PubMed ID: 3303121
[TBL] [Abstract][Full Text] [Related]
12. Distribution of ventilation/perfusion ratios in pulmonary embolism: an adjunct to the interpretation of ventilation/perfusion lung scans.
Itti E; Nguyen S; Robin F; Desarnaud S; Rosso J; Harf A; Meignan M
J Nucl Med; 2002 Dec; 43(12):1596-602. PubMed ID: 12468507
[TBL] [Abstract][Full Text] [Related]
13. Efficient lung scintigraphy.
Tägil K; Evander E; Wollmer P; Palmer J; Jonson B
Clin Physiol; 2000 Mar; 20(2):95-100. PubMed ID: 10735975
[TBL] [Abstract][Full Text] [Related]
14. Pulmonary embolism: diagnosis with spiral CT and ventilation-perfusion scanning--correlation with pulmonary angiographic results or clinical outcome.
Garg K; Welsh CH; Feyerabend AJ; Subber SW; Russ PD; Johnston RJ; Durham JD; Lynch DA
Radiology; 1998 Jul; 208(1):201-8. PubMed ID: 9646814
[TBL] [Abstract][Full Text] [Related]
15. The use of 99Tcm-DTPA aerosol ventilation scintigraphy in the diagnosis of pulmonary embolism.
Buxton-Thomas MS; Wraight EP
Nucl Med Commun; 1984 Jun; 5(6):387-91. PubMed ID: 6397705
[TBL] [Abstract][Full Text] [Related]
16. Serial lung scintigraphy: utility in diagnosis of pulmonary embolism.
Alderson PO; Dzebolo NN; Biello DR; Seldin DW; Martin EC; Siegel BA
Radiology; 1983 Dec; 149(3):797-802. PubMed ID: 6227931
[TBL] [Abstract][Full Text] [Related]
17. Significance of single ventilation/perfusion mismatches in krypton-81m/technetium-99m lung scintigraphy.
Rosen JM; Palestro CJ; Markowitz D; Alderson PO
J Nucl Med; 1986 Mar; 27(3):361-5. PubMed ID: 3712054
[TBL] [Abstract][Full Text] [Related]
18. Lower limb deep vein thrombosis in patients with suspected pulmonary embolism detected with (99m)Tc-MAA simultaneously with lung perfusion scan.
Shao W; Zhang F; Zuo S; Wang X; Song J
Hell J Nucl Med; 2012; 15(3):220-3. PubMed ID: 23106054
[TBL] [Abstract][Full Text] [Related]
19. [Ventilation scintigraphy with 127Xenon gas--efficient use for emergency diagnosis of pulmonary embolism].
Müller-Brand J; Fridrich R
Schweiz Med Wochenschr; 1984 Dec; 114(48):1741-3. PubMed ID: 6523101
[TBL] [Abstract][Full Text] [Related]
20. Correlation of diagnostic imaging and subsequent autopsy findings in patients with pulmonary embolism.
Patriquin L; Khorasani R; Polak JF
AJR Am J Roentgenol; 1998 Aug; 171(2):347-9. PubMed ID: 9694449
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]