These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
110 related articles for article (PubMed ID: 9214785)
1. The inaccuracy of Kubicek's one-cylinder model in thoracic impedance cardiography. Raaijmakers E; Faes TJ; Goovaerts HG; de Vries PM; Heethaar RM IEEE Trans Biomed Eng; 1997 Jan; 44(1):70-6. PubMed ID: 9214785 [TBL] [Abstract][Full Text] [Related]
2. Noninvasive assessment of cardiac performance by impedance cardiography: disagreement between two equations to estimate stroke volume. de Mey C; Enterling D Aviat Space Environ Med; 1988 Jan; 59(1):57-62. PubMed ID: 3355468 [TBL] [Abstract][Full Text] [Related]
3. The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients. Woltjer HH; Bogaard HJ; van der Spoel HI; de Vries PM Intensive Care Med; 1996 Aug; 22(8):766-71. PubMed ID: 8880245 [TBL] [Abstract][Full Text] [Related]
4. Towards a theoretical understanding of stroke volume estimation with impedance cardiography. Faes TJ; Raaijmakers E; Meijer JH; Goovaerts HG; Heethaar RM Ann N Y Acad Sci; 1999 Apr; 873():128-34. PubMed ID: 10372160 [TBL] [Abstract][Full Text] [Related]
5. A finite-element study of the effects of electrode position on the measured impedance change in impedance cardiography. Wang Y; Haynor DR; Kim Y IEEE Trans Biomed Eng; 2001 Dec; 48(12):1390-401. PubMed ID: 11759920 [TBL] [Abstract][Full Text] [Related]
6. The influence of extravascular lung water on cardiac output measurements using thoracic impedance cardiography. Raaijmakers E; Faes TJ; Kunst PW; Bakker J; Rommes JH; Goovaerts HG; Heethaar RM Physiol Meas; 1998 Nov; 19(4):491-9. PubMed ID: 9863675 [TBL] [Abstract][Full Text] [Related]
7. Hemodynamic evaluation in pregnancy: limitations of impedance cardiography. Moertl MG; Schlembach D; Papousek I; Hinghofer-Szalkay H; Weiss EM; Lang U; Lackner HK Physiol Meas; 2012 Jun; 33(6):1015-26. PubMed ID: 22562970 [TBL] [Abstract][Full Text] [Related]
8. Stroke volume measurement by impedance cardiography using a formula based on the delta z waveform. Granerus G; Elg R Clin Phys Physiol Meas; 1982 May; 3(2):131-9. PubMed ID: 6126290 [TBL] [Abstract][Full Text] [Related]
9. Validation of impedance cardiography during lower body negative pressure. Gotshall RW; Davrath LR; Sadeh WZ; Coonts CC; Luckasen GJ; Downes TR; Tucker A Aviat Space Environ Med; 1999 Jan; 70(1):6-10. PubMed ID: 9895014 [TBL] [Abstract][Full Text] [Related]
10. Standardization of non-invasive impedance cardiography for assessment of stroke volume: comparison with thermodilution. Woltjer HH; Bogaard HJ; Scheffer GJ; van der Spoel HI; Huybregts MA; de Vries PM Br J Anaesth; 1996 Dec; 77(6):748-52. PubMed ID: 9014628 [TBL] [Abstract][Full Text] [Related]
11. Transthoracic impedance: differences between men and women with implications for impedance cardiography. Frey MA; Doerr BM; Miles DS Aviat Space Environ Med; 1982 Dec; 53(12):1190-2. PubMed ID: 7159339 [TBL] [Abstract][Full Text] [Related]
12. Impedance cardiography using band and regional electrodes in supine, sitting, and during exercise. Patterson RP; Wang L; Raza SB IEEE Trans Biomed Eng; 1991 May; 38(5):393-400. PubMed ID: 1874520 [TBL] [Abstract][Full Text] [Related]
13. [Simulation study of Kubicek formula for cardiac stroke volume calculation by 3-dimensional finite element method]. Wang H; Wang J; Dong X; Qi J Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2002 Jan; 19(1):89-92. PubMed ID: 11951532 [TBL] [Abstract][Full Text] [Related]
14. [Reliability and effectiveness of monitoring the stroke and minute volume of the heart by Kubicek's rheographic method]. Genin AM; Zingerman LS; Maksimov DG; Belozerov GE; Katuntsev VP Kosm Biol Aviakosm Med; 1984; 18(3):9-14. PubMed ID: 6737989 [TBL] [Abstract][Full Text] [Related]
15. Parametric EIT for monitoring cardiac stroke volume. Zlochiver S; Freimark D; Arad M; Adunsky A; Abboud S Physiol Meas; 2006 May; 27(5):S139-46. PubMed ID: 16636406 [TBL] [Abstract][Full Text] [Related]
16. Stroke volume equation for impedance cardiography. Bernstein DP; Lemmens HJ Med Biol Eng Comput; 2005 Jul; 43(4):443-50. PubMed ID: 16255425 [TBL] [Abstract][Full Text] [Related]
17. Gender and age differences in transthoracic bioimpedance. Metry G; Wikström B; Linde T; Danielson BG Acta Physiol Scand; 1997 Oct; 161(2):171-5. PubMed ID: 9366959 [TBL] [Abstract][Full Text] [Related]
18. Thoracic geometry and its relation to electrical current distribution: consequences for electrode placement in electrical impedance cardiography. Raaijmakers E; Faes TJ; Goovaerts HG; Meijer JH; de Vries PM; Heethaar RM Med Biol Eng Comput; 1998 Sep; 36(5):592-7. PubMed ID: 10367443 [TBL] [Abstract][Full Text] [Related]
19. Comparing square root method of measuring the cardiac output by means of aortic impedance change component to Kubicek's method. Kuang MX; Kuang SJ; Xiao QJ; Kuang NZ; Zhao H; Cheng XL Med Phys; 2018 Jul; ():. PubMed ID: 29963701 [TBL] [Abstract][Full Text] [Related]
20. Impedance cardiography in healthy children and children with congenital heart disease: Improving stroke volume assessment. Nederend I; Ten Harkel ADJ; Blom NA; Berntson GG; de Geus EJC Int J Psychophysiol; 2017 Oct; 120():136-147. PubMed ID: 28778397 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]