  • 21. [Transcutaneous blood gas measurements in ergometry].
    Breuer HW; Groeben H; Worth H; Strauer BE
    Pneumologie; 1990 Feb; 44 Suppl 1():629-30. PubMed ID: 2114640
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Evaluation of a combined transcutaneous carbon dioxide pressure and pulse oximetry sensor in adult sheep and dogs.
    Vogt R; Rohling R; Kästner S
    Am J Vet Res; 2007 Mar; 68(3):265-70. PubMed ID: 17331015
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Successful management of a patient with pulmonary arteriovenous fistula using a continuous intra-arterial blood gas monitoring system].
    Habuka K; Ishikawa S; Makita K
    Masui; 1999 Jun; 48(6):647-9. PubMed ID: 10402819
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Room air ventilation for total intravenous general anaesthesia.
    Cardan E; Pascu A; Popescu S
    Ann Fr Anesth Reanim; 1988; 7(6):449-51. PubMed ID: 3146935
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Advances in studies of blood gases].
    Müller J
    Pneumonol Pol; 1987 Oct; 55(10):439-43. PubMed ID: 3125524
    [No Abstract]   [Full Text] [Related]  

  • 26. [Effects of different respiratory rates on PaCO2 and plasma potassium concentration].
    Li Y; Sun L
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2004 May; 35(3):385-7. PubMed ID: 15181844
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Transcutaneous oxygen monitoring in congenital diaphragmatic abnormalities.
    Gibbons M
    Nurs Crit Care; 1997; 2(3):132-7. PubMed ID: 9873314
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The effect of temperature correction of blood gas values on the accuracy of end-tidal carbon dioxide monitoring in children after cardiac surgery.
    Suominen PK; Stayer S; Wang W; Chang AC
    ASAIO J; 2007; 53(6):670-4. PubMed ID: 18043144
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Acid-base equilibrium and gas composition indices of the arterial blood during induction anesthesia in neurosurgical patients].
    Stolkarts IZ; Uglov VV; Torgovtsev AA
    Anesteziol Reanimatol; 1980; (1):12-4. PubMed ID: 6769366
    [No Abstract]   [Full Text] [Related]  

  • 30. Agreement of carbon dioxide levels measured by arterial, transcutaneous and end tidal methods in preterm infants < or = 28 weeks gestation.
    Aliwalas LL; Noble L; Nesbitt K; Fallah S; Shah V; Shah PS
    J Perinatol; 2005 Jan; 25(1):26-9. PubMed ID: 15496874
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of the transcutaneous oxygen and carbon dioxide tension in different electrode locations during general anaesthesia.
    Nishiyama T; Nakamura S; Yamashita K
    Eur J Anaesthesiol; 2006 Dec; 23(12):1049-54. PubMed ID: 16824244
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Transcutaneous measurement of carbon dioxide tension during long-distance transport of neonates receiving mechanical ventilation.
    O'Connor TA; Grueber R
    J Perinatol; 1998; 18(3):189-92. PubMed ID: 9659646
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Blood gas changes in patients undergoing laryngeal microsurgery.
    Cinar SO; Coskun BU; Cinar U; Erol MK; Oba S; Dadas B
    Auris Nasus Larynx; 2006 Sep; 33(3):299-302. PubMed ID: 16529898
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [Mechanical ventilation of acute exacerbated chronic obstructive pulmonary disease with CO2 retention].
    Yang MS; Peng Y; Xing W
    Hunan Yi Ke Da Xue Xue Bao; 2003 Aug; 28(4):429-30. PubMed ID: 14653140
    [No Abstract]   [Full Text] [Related]  

  • 35. Validation study of a transcutaneous carbon dioxide monitor in patients in the emergency department.
    McVicar J; Eager R
    Emerg Med J; 2009 May; 26(5):344-6. PubMed ID: 19386868
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transcutaneous blood gas monitoring in the rat.
    Stout RW; Cho DY; Gaunt SD; Taylor HW; Baker DG
    Comp Med; 2001 Dec; 51(6):524-33. PubMed ID: 11924815
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Determination of reference ranges for transcutaneous oxygen and carbon dioxide tension and the oxygen challenge test in healthy and morbidly obese subjects.
    Nishiguchi BK; Yu M; Suetsugu A; Jiang C; Takiguchi SA; Takanishi DM
    J Surg Res; 2008 Dec; 150(2):204-11. PubMed ID: 18262560
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Fiber optics oximetry of blood in the upper bulb of the internal jugular vein in heart surgery].
    Mierbekov EM; Flerov EV; Dement'eva II; Iavorskiĭ AG; Shmyrin MM
    Anesteziol Reanimatol; 1997; (1):35-8. PubMed ID: 9173815
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The effects of different analgesic regimens on transcutaneous CO2 after major surgery.
    McCormack JG; Kelly KP; Wedgwood J; Lyon R
    Anaesthesia; 2008 Aug; 63(8):814-21. PubMed ID: 18699897
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Repeated blood gas monitoring in healthy children and adolescents by the transcutaneous route.
    Lagerkvist AL; Sten G; Redfors S; Holmgren D
    Pediatr Pulmonol; 2003 Apr; 35(4):274-9. PubMed ID: 12629624
    [TBL] [Abstract][Full Text] [Related]  