These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 9225194)

  • 1. Clinical application of cardiac output during ramp exercise calculated using the Fick equation--comparison with the 2-stage bicycle ergometer exercise protocol in the supine position.
    Yamabe H; Itho K; Yasaka Y; Yokoyama M
    Jpn Circ J; 1997 Jun; 61(6):488-94. PubMed ID: 9225194
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemodynamic characteristics during treadmill and bicycle exercise in chronic heart failure: mechanism for different responses of peak oxygen uptake.
    Kim S; Yamabe H; Yokoyama M
    Jpn Circ J; 1999 Dec; 63(12):965-70. PubMed ID: 10614842
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cardiac output, oxygen consumption and arteriovenous oxygen difference following a sudden rise in exercise level in humans.
    De Cort SC; Innes JA; Barstow TJ; Guz A
    J Physiol; 1991 Sep; 441():501-12. PubMed ID: 1816384
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Continuous Fick cardiac output measurement during exercise by monitoring of mixed venous oxygen saturation and oxygen uptake.
    Nakanishi N; Yoshioka T; Okano Y; Nishimura T
    Chest; 1993 Aug; 104(2):419-26. PubMed ID: 8339630
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison between measured and fick-derived values of hemodynamic and oxymetric variables in patients with acute myocardial infarction.
    Pomés Iparraguirre H; Giniger R; Garber VA; Quiroga E; Jorge MA
    Am J Med; 1988 Sep; 85(3):349-52. PubMed ID: 3414730
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.
    Chang AC; Kulik TJ; Hickey PR; Wessel DL
    Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Estimating exercise stroke volume from asymptotic oxygen pulse in humans.
    Whipp BJ; Higgenbotham MB; Cobb FC
    J Appl Physiol (1985); 1996 Dec; 81(6):2674-9. PubMed ID: 9018521
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cardiac output during exercise: a comparison of four methods.
    Siebenmann C; Rasmussen P; Sørensen H; Zaar M; Hvidtfeldt M; Pichon A; Secher NH; Lundby C
    Scand J Med Sci Sports; 2015 Feb; 25(1):e20-7. PubMed ID: 24646113
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The effect of progressive exercise on the equilibrium rebreathing cardiac output method.
    Auchincloss JH; Gilbert R; Morales R; Peppi D
    Med Sci Sports Exerc; 1991 Sep; 23(9):1111-5. PubMed ID: 1943634
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measurement of cardiac output by CO2 rebreathing in unsteady state exercise.
    McKelvie RS; Heigenhauser GJ; Jones NL
    Chest; 1987 Nov; 92(5):777-82. PubMed ID: 3117498
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Oxygen Fick and modified carbon dioxide Fick cardiac outputs.
    Mahutte CK; Jaffe MB; Chen PA; Sasse SA; Wong DH; Sassoon CS
    Crit Care Med; 1994 Jan; 22(1):86-95. PubMed ID: 8124981
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of exercise cardiac output by the Fick principle using oxygen and carbon dioxide.
    Sun XG; Hansen JE; Ting H; Chuang ML; Stringer WW; Adame D; Wasserman K
    Chest; 2000 Sep; 118(3):631-40. PubMed ID: 10988183
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reproducibility of the exponential rise technique of CO(2) rebreathing for measuring P(v)CO(2) and C(v)CO(2 )to non-invasively estimate cardiac output during incremental, maximal treadmill exercise.
    Cade WT; Nabar SR; Keyser RE
    Eur J Appl Physiol; 2004 May; 91(5-6):669-76. PubMed ID: 14652761
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Cardiopulmonary exercise evaluation: value and influence of the use of a ramp protocol versus triangular protocol].
    Grentzinger A; Suleiman A; Selton-Suty C; Juillière Y; Uffholtz H; Cherrier F
    Arch Mal Coeur Vaiss; 1994 Nov; 87(11):1395-400. PubMed ID: 7771885
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardiorespiratory variables during a continuous ramp exercise protocol in normal young adults.
    Matthys D; Pannier JL; Taeymans Y; Verhaaren H
    Acta Cardiol; 1996; 51(5):451-9. PubMed ID: 8922050
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Increased cardiac output elicits higher V̇O2max in response to self-paced exercise.
    Astorino TA; McMillan DW; Edmunds RM; Sanchez E
    Appl Physiol Nutr Metab; 2015 Mar; 40(3):223-9. PubMed ID: 25682980
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of measurement errors on cardiac output calculated with O2 and modified CO2 Fick methods.
    Mahutte CK; Jaffe MB
    J Clin Monit; 1995 Mar; 11(2):99-108. PubMed ID: 7760094
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reference Values for Peak Exercise Cardiac Output in Healthy Individuals.
    Agostoni P; Vignati C; Gentile P; Boiti C; Farina S; Salvioni E; Mapelli M; Magrì D; Paolillo S; Corrieri N; Sinagra G; Cattadori G
    Chest; 2017 Jun; 151(6):1329-1337. PubMed ID: 28108178
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cardiac output estimated noninvasively from oxygen uptake during exercise.
    Stringer WW; Hansen JE; Wasserman K
    J Appl Physiol (1985); 1997 Mar; 82(3):908-12. PubMed ID: 9074981
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A method for assessing heterogeneity of blood flow and metabolism in exercising normal human muscle by near-infrared spectroscopy.
    Vogiatzis I; Habazettl H; Louvaris Z; Andrianopoulos V; Wagner H; Zakynthinos S; Wagner PD
    J Appl Physiol (1985); 2015 Mar; 118(6):783-93. PubMed ID: 25593285
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.