These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

101 related articles for article (PubMed ID: 9225344)

  • 1. A new approach to estimate changes in total body water by bioelectrical impedance analysis.
    Lukaski HC
    Nutrition; 1997 May; 13(5):474-5. PubMed ID: 9225344
    [No Abstract]   [Full Text] [Related]  

  • 2. Volaemic assessment of the elderly hyponatraemic patient: reliability of clinical assessment and validation of bioelectrical impedance analysis.
    Hoyle GE; Chua M; Soiza RL
    QJM; 2011 Jan; 104(1):35-9. PubMed ID: 20823196
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bioelectrical impedance analysis during acute changes of extracellular osmolality in man.
    Berneis K; Keller U
    Clin Nutr; 2000 Oct; 19(5):361-6. PubMed ID: 11031076
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bioelectrical impedance to estimate changes in hydration status.
    O'Brien C; Young AJ; Sawka MN
    Int J Sports Med; 2002 Jul; 23(5):361-6. PubMed ID: 12165888
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bioelectrical impedance spectroscopy to estimate fluid balance in critically ill patients.
    Dewitte A; Carles P; Joannès-Boyau O; Fleureau C; Roze H; Combe C; Ouattara A
    J Clin Monit Comput; 2016 Apr; 30(2):227-33. PubMed ID: 26018457
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Body mass index and bioelectrical vector distribution in 8-year-old children.
    Guida B; Pietrobelli A; Trio R; Laccetti R; Falconi C; Perrino NR; Principato S; Pecoraro P
    Nutr Metab Cardiovasc Dis; 2008 Feb; 18(2):133-41. PubMed ID: 17307345
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Is bioelectrical impedance vector analysis of value in the elderly with malnutrition and impaired functionality?
    Norman K; Smoliner C; Valentini L; Lochs H; Pirlich M
    Nutrition; 2007; 23(7-8):564-9. PubMed ID: 17616343
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Single-frequency and multi-frequency bioimpedance analysis: What is the difference?
    Yalin SF; Gulcicek S; Avci S; Erkalma Senates B; Altiparmak MR; Trabulus S; Alagoz S; Yavuzer H; Doventas A; Seyahi N
    Nephrology (Carlton); 2018 May; 23(5):438-445. PubMed ID: 28295857
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Measurement of total body water in children using bioelectrical impedance: a comparison of several prediction equations.
    Beertema W; van Hezewijk M; Kester A; Forget PP; van Kreel B
    J Pediatr Gastroenterol Nutr; 2000 Oct; 31(4):428-32. PubMed ID: 11045842
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Determination of total body water in uraemic patients by bioelectrical impedance.
    Kong CH; Thompson CM; Lewis CA; Hill PD; Thompson FD
    Nephrol Dial Transplant; 1993; 8(8):716-9. PubMed ID: 8414157
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of foot-to-foot bioelectrical impedance analysis for the prediction of total body water in oncology outpatients receiving radiotherapy.
    Isenring E; Bauer J; Capra S; Davies PS
    Eur J Clin Nutr; 2004 Jan; 58(1):46-51. PubMed ID: 14679366
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bioelectrical impedance analysis for assessment of fluid status and body composition in neonates--the good, the bad and the unknown.
    Lingwood BE
    Eur J Clin Nutr; 2013 Jan; 67 Suppl 1():S28-33. PubMed ID: 23299869
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Total body water in elderly adults--assessing hydration status by bioelectrical impedance analysis vs urine osmolality.
    Powers JS; Buchowski M; Wang L; Otoo-Boameh A
    J Am Geriatr Soc; 2012 Feb; 60(2):388-90. PubMed ID: 22332693
    [No Abstract]   [Full Text] [Related]  

  • 14. The effect of acute fluid consumption on measures of impedance and percent body fat using leg-to-leg bioelectrical impedance analysis.
    Dixon CB; LoVallo SJ; Andreacci JL; Goss FL
    Eur J Clin Nutr; 2006 Jan; 60(1):142-6. PubMed ID: 16234840
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of change in hydration in women during pregnancy and postpartum with bioelectrical impedance vectors.
    Lukaski HC; Hall CB; Siders WA
    Nutrition; 2007; 23(7-8):543-50. PubMed ID: 17570642
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extracellular water and total body water estimated by multifrequency bioelectrical impedance analysis in healthy cats: a cross-validation study.
    Elliott DA; Backus RC; Van Loan MD; Rogers QR
    J Nutr; 2002 Jun; 132(6 Suppl 2):1760S-2S. PubMed ID: 12042519
    [No Abstract]   [Full Text] [Related]  

  • 17. Estimates of body water compartments with use of bioelectrical impedance analysis.
    Nunez C
    Am J Clin Nutr; 2001 Apr; 73(4):845-6. PubMed ID: 11273864
    [No Abstract]   [Full Text] [Related]  

  • 18. Bipedal bioelectrical impedance analysis reproducibly estimates total body water in hemodialysis patients.
    Kushner RF; Roxe DM
    Am J Kidney Dis; 2002 Jan; 39(1):154-8. PubMed ID: 11774114
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biological indexes considered in the derivation of the bioelectrical impedance analysis.
    Lukaski HC
    Am J Clin Nutr; 1996 Sep; 64(3 Suppl):397S-404S. PubMed ID: 8780355
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of multifrequency bioelectrical impedance analysis for the assessment of extracellular and total body water in healthy cats.
    Elliott DA; Backus RC; Van Loan MD; Rogers QR
    J Nutr; 2002 Jun; 132(6 Suppl 2):1757S-9S. PubMed ID: 12042518
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.