These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 9234088)

  • 1. Evaluation of the AVOXimeter: precision, long-term stability, linearity, and use without heparin.
    Bailey SR; Russell EL; Martinez A
    J Clin Monit; 1997 May; 13(3):191-8. PubMed ID: 9234088
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of the HB-Quick: a portable hemoglobinometer.
    Gong AK; Backenstose B
    J Clin Monit Comput; 1999 May; 15(3-4):171-7. PubMed ID: 12568168
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of two oximeters for use in cardiac catheterization laboratories.
    Freeman GL; Steinke JM
    Cathet Cardiovasc Diagn; 1993 Sep; 30(1):51-7. PubMed ID: 8402867
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Near-patient measurements of methemoglobin, oxygen saturation, and total hemoglobin: evaluation of a new instrument for adult and neonatal intensive care.
    Gong AK
    Crit Care Med; 1995 Jan; 23(1):193-201. PubMed ID: 7528117
    [TBL] [Abstract][Full Text] [Related]  

  • 5. CO-oximetry interference by perflubron emulsion: comparison of hemolyzing and nonhemolyzing instruments.
    Shepherd AP; Steinke JM
    Clin Chem; 1998 Oct; 44(10):2183-90. PubMed ID: 9761254
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Correct and spurious calibration of the Oxicom oximeter.
    Russell EL
    Cathet Cardiovasc Diagn; 1994 Nov; 33(3):264-6. PubMed ID: 7874723
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of carboxyhemoglobin on the accuracy of mixed venous oximetry monitors in dogs.
    Haney M; Tait AR; Tremper KK
    Crit Care Med; 1994 Jul; 22(7):1181-5. PubMed ID: 8026210
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of point-of-care haemoglobin measuring devices: a comparison of Radical-7™ pulse co-oximetry, HemoCue(®) and laboratory haemoglobin measurements in obstetric patients*.
    Skelton VA; Wijayasinghe N; Sharafudeen S; Sange A; Parry NS; Junghans C
    Anaesthesia; 2013 Jan; 68(1):40-5. PubMed ID: 23088815
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Signalprocessing in transmission pulse hemometry.
    Sánchez A; Abdallah O; Schöchlin J; Bolz A
    Biomed Tech (Berl); 2002; 47 Suppl 1 Pt 2():839-41. PubMed ID: 12465318
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a Portable Blood Gas Analyzer for Prehospital Triage in Carbon Monoxide Poisoning: Instrument Validation Study.
    Lyon M; Fehlmann CA; Augsburger M; Schaller T; Zimmermann-Ivol C; Celi J; Gartner BA; Lorenzon N; Sarasin F; Suppan L
    JMIR Form Res; 2023 Oct; 7():e48057. PubMed ID: 37801355
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pulse Oximetry Overestimates Oxyhemoglobin in Neonates with Critical Congenital Heart Disease.
    Murphy D; Pak Y; Cleary JP
    Neonatology; 2016; 109(3):213-8. PubMed ID: 26800085
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Simultaneous determination of hemoglobin derivatives, oxygen content, oxygen capacity, and oxygen saturation in 10 microliters of whole blood.
    Rossi-Bernardi L; Perella M; Luzzana M; Samaja M; Raffaele I
    Clin Chem; 1977 Jul; 23(7):1215-25. PubMed ID: 872367
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Precision and accuracy of "a pocket" pulse oximeter in Mexico City].
    Torre-Bouscoulet L; Chávez-Plascencia E; Vázquez-García JC; Pérez-Padilla R
    Rev Invest Clin; 2006; 58(1):28-33. PubMed ID: 16789596
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reflectance measurements of hematocrit and oxyhemoglobin saturation.
    Steinke JM; Shepherd AP
    Am J Physiol; 1987 Jul; 253(1 Pt 2):H147-53. PubMed ID: 3605361
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of pulse oximetry during hypoxemia.
    Thrush D; Hodges MR
    South Med J; 1994 Apr; 87(4):518-21. PubMed ID: 8153783
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Response of 10 pulse oximeters to an in vitro test system.
    Reynolds KJ; Moyle JT; Sykes MK; Hahn CE
    Br J Anaesth; 1992 Apr; 68(4):365-9. PubMed ID: 1642914
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous noninvasive hemoglobin monitoring during complex spine surgery.
    Berkow L; Rotolo S; Mirski E
    Anesth Analg; 2011 Dec; 113(6):1396-402. PubMed ID: 21965372
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Pulse total-hemoglobinometer provides accurate noninvasive monitoring.
    Noiri E; Kobayashi N; Takamura Y; Iijima T; Takagi T; Doi K; Nakao A; Yamamoto T; Takeda S; Fujita T
    Crit Care Med; 2005 Dec; 33(12):2831-5. PubMed ID: 16352948
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Potential errors in pulse oximetry. I. Pulse oximeter evaluation.
    Ralston AC; Webb RK; Runciman WB
    Anaesthesia; 1991 Mar; 46(3):202-6. PubMed ID: 2014898
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.