These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

51 related articles for article (PubMed ID: 9234140)

  • 1. Use of polyetherurethane to improve the biocompatibility of vascular stents.
    Fontaine AB; Dos Passos S; Spigos D; Cearlock J; Urbaneja A
    J Endovasc Surg; 1995 Aug; 2(3):255-65. PubMed ID: 9234140
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of three polytetrafluoroethylene stent-grafts in a model of neointimal hyperplasia.
    Dolmatch B; Dong YH; Heeter Z
    J Vasc Interv Radiol; 2007 Apr; 18(4):527-34. PubMed ID: 17446544
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Polytetrafluoroethylene-covered stents in the venous and arterial system: angiographic and pathologic findings in a swine model.
    Gordon BM; Fishbein MC; Levi DS
    Cardiovasc Pathol; 2008; 17(4):206-11. PubMed ID: 18402810
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Polymeric covers and coats for metallic stents: microporous PTFE and the inhibition of intimal hyperplasia.
    Diethrich EB
    J Endovasc Surg; 1995 Aug; 2(3):266-71. PubMed ID: 9234141
    [No Abstract]   [Full Text] [Related]  

  • 5. Matrigel-coated stents reduce intimal thickening in a large animal vascular stent model.
    Tso C; Skinner MP; Hawthorne WJ; Fletcher JP
    Int Angiol; 2002 Sep; 21(3):244-9. PubMed ID: 12384645
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sirolimus-eluting stents to abolish intimal hyperplasia and improve flow in porcine arteriovenous grafts: a 4-week follow-up study.
    Rotmans JI; Pattynama PM; Verhagen HJ; Hino I; Velema E; Pasterkamp G; Stroes ES
    Circulation; 2005 Mar; 111(12):1537-42. PubMed ID: 15781738
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Particle debris from a nanoporous stent coating obscures potential antiproliferative effects of tacrolimus-eluting stents in a porcine model of restenosis.
    Kollum M; Farb A; Schreiber R; Terfera K; Arab A; Geist A; Haberstroh J; Wnendt S; Virmani R; Hehrlein C
    Catheter Cardiovasc Interv; 2005 Jan; 64(1):85-90. PubMed ID: 15619311
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Polymer stent coating for prevention of neointimal hyperplasia.
    Billinger M; Buddeberg F; Hubbell JA; Elbert DL; Schaffner T; Mettler D; Windecker S; Meier B; Hess OM
    J Invasive Cardiol; 2006 Sep; 18(9):423-6; discussion 427. PubMed ID: 16954581
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Local methylprednisolone delivery using a BiodivYsio phosphorylcholine-coated drug-delivery stent reduces inflammation and neointimal hyperplasia in a porcine coronary stent model.
    Huang Y; Liu X; Wang L; Verbeken E; Li S; De Scheerder I
    Int J Cardiovasc Intervent; 2003; 5(3):166-71. PubMed ID: 12959735
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Metallic surface modification.
    De Scheerder I; Verbeken E; Van Humbeeck J
    Semin Interv Cardiol; 1998; 3(3-4):139-44. PubMed ID: 10406683
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Synergistic effects of a novel nanoporous stent coating and tacrolimus on intima proliferation in rabbits.
    Wieneke H; Dirsch O; Sawitowski T; Gu YL; Brauer H; Dahmen U; Fischer A; Wnendt S; Erbel R
    Catheter Cardiovasc Interv; 2003 Nov; 60(3):399-407. PubMed ID: 14571494
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel drug-eluting stent coated with an integrin-binding cyclic Arg-Gly-Asp peptide inhibits neointimal hyperplasia by recruiting endothelial progenitor cells.
    Blindt R; Vogt F; Astafieva I; Fach C; Hristov M; Krott N; Seitz B; Kapurniotu A; Kwok C; Dewor M; Bosserhoff AK; Bernhagen J; Hanrath P; Hoffmann R; Weber C
    J Am Coll Cardiol; 2006 May; 47(9):1786-95. PubMed ID: 16682302
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effects of cytochalasin D-eluting stents on intimal hyperplasia in a porcine coronary artery model.
    Salu KJ; Bosmans JM; Huang Y; Hendriks M; Verhoeven M; Levels A; Cooper S; De Scheerder IK; Vrints CJ; Bult H
    Cardiovasc Res; 2006 Feb; 69(2):536-44. PubMed ID: 16386237
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Arsenic trioxide eluting stent reduces neointima formation in a rabbit iliac artery injury model.
    Yang W; Ge J; Liu H; Zhao K; Liu X; Qu X; Li W; Huang Y; Sun A; Zou Y
    Cardiovasc Res; 2006 Dec; 72(3):483-93. PubMed ID: 17020754
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stent-based nitric oxide delivery reducing neointimal proliferation in a porcine carotid overstretch injury model.
    Hou D; Narciso H; Kamdar K; Zhang P; Barclay B; March KL
    Cardiovasc Intervent Radiol; 2005; 28(1):60-5. PubMed ID: 15719180
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of surface texture and charge on the biocompatibility of endovascular stents.
    Hehrlein C; Zimmermann M; Metz J; Ensinger W; Kübler W
    Coron Artery Dis; 1995 Jul; 6(7):581-6. PubMed ID: 7582197
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Paclitaxel-coated expanded polytetrafluoroethylene haemodialysis grafts inhibit neointimal hyperplasia in porcine model of graft stenosis.
    Lee BH; Nam HY; Kwon T; Kim SJ; Kwon GY; Jeon HJ; Lim HJ; Lee WK; Park JS; Ko JY; Kim DJ
    Nephrol Dial Transplant; 2006 Sep; 21(9):2432-8. PubMed ID: 16554328
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Novel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries.
    Buszman P; Milewski K; Zurakowski A; Pajak J; Liszka Ł; Buszman P; Musioł E; AbuSamra M; Trznadel S; Kałuza G
    Kardiol Pol; 2010 May; 68(5):503-9. PubMed ID: 20491008
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Vascular endothelial growth factor (VEGF)-eluting stents: in vivo effects on thrombosis, endothelialization and intimal hyperplasia.
    Swanson N; Hogrefe K; Javed Q; Malik N; Gershlick AH
    J Invasive Cardiol; 2003 Dec; 15(12):688-92. PubMed ID: 14660819
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Polymeric surface modifications of tantalum stents.
    Fontaine AB; Koelling K; Passos SD; Cearlock J; Hoffman R; Spigos DG
    J Endovasc Surg; 1996 Aug; 3(3):276-83. PubMed ID: 8800230
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 3.