These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 9240672)

  • 101. A new method of measuring the femoral anteversion and neck-shaft angles.
    Proubasta IR; Lluch AL; Roig JL; Palacio AH; Caceres JS; Araño RG
    Clin Radiol; 1984 Jul; 35(4):323-6. PubMed ID: 6734069
    [TBL] [Abstract][Full Text] [Related]  

  • 102. Elimination of the Femoral Neck in Measuring Femoral Version Allows for Less Variance in Interobserver Reliability.
    Dimovski R; Teitge R; Bolz N; Schafer P; Bobba V; Vaidya R
    Medicina (Kaunas); 2021 Dec; 57(12):. PubMed ID: 34946310
    [No Abstract]   [Full Text] [Related]  

  • 103. Bilateral symmetrical comparison of the proximal femur using 3D-CT models.
    Dolatowski FC; Temmesfeld MJ; Pierre-Jerome C; Borthne A; Hoelsbrekken SE
    Surg Radiol Anat; 2018 May; 40(5):507-513. PubMed ID: 29322292
    [TBL] [Abstract][Full Text] [Related]  

  • 104. Analysis of Computed Tomography-Based Technique for Measuring Femoral Anteversion: Implications for Measuring Rotation After Femoral Intramedullary Nail Insertion.
    McAlister IP; Marchand LS; Napora JK; Riedel MD; Shannon SS; O'Hara NN; Langhammer CG; LeBrun C; Nascone JW; Sciadini MF; O'Toole RV
    J Orthop Trauma; 2021 May; 35(5):239-244. PubMed ID: 32956208
    [TBL] [Abstract][Full Text] [Related]  

  • 105. A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws.
    Zhang YL; Zhang W; Zhang CQ
    Orthop Traumatol Surg Res; 2017 Apr; 103(2):229-234. PubMed ID: 28093376
    [TBL] [Abstract][Full Text] [Related]  

  • 106. Diagnosis of femoral neck fracture associated with femoral shaft fracture: blinded comparison of computed tomography and plain radiography.
    OʼToole RV; Dancy L; Dietz AR; Pollak AN; Johnson AJ; Osgood G; Nascone JW; Sciadini MF; Castillo RC
    J Orthop Trauma; 2013 Jun; 27(6):325-30. PubMed ID: 22955334
    [TBL] [Abstract][Full Text] [Related]  

  • 107. Determination of Femoral Neck Angle and Torsion Angle Utilizing a Novel Three-Dimensional Modeling and Analytical Technology Based on CT Datasets.
    Hartel MJ; Petersik A; Schmidt A; Kendoff D; Nüchtern J; Rueger JM; Lehmann W; Grossterlinden LG
    PLoS One; 2016; 11(3):e0149480. PubMed ID: 26933877
    [TBL] [Abstract][Full Text] [Related]  

  • 108. CT based measurement of anatomical dimensions of femur and its relevance in nail designs for proximal femoral fractures.
    Kulkarni M; Naik A M; Shetty CB; Paruthikunnan SM; Rao SK
    J Orthop; 2020; 20():63-69. PubMed ID: 32042232
    [TBL] [Abstract][Full Text] [Related]  

  • 109. Anteversion Angle Measurement in Suspected Torsional Malalignment of the Femur in 3-Dimensional EOS vs Computed Tomography-A Validation Study.
    Mayr HO; Schmidt JP; Haasters F; Bernstein A; Schmal H; Prall WC
    J Arthroplasty; 2021 Jan; 36(1):379-386. PubMed ID: 32826141
    [TBL] [Abstract][Full Text] [Related]  

  • 110. Introduction of a bone-centered three-dimensional coordinate system enables computed tomographic canine femoral angle measurements independent of positioning.
    Brühschwein A; Schmitz B; Zöllner M; Reese S; Meyer-Lindenberg A
    Front Vet Sci; 2022; 9():1019215. PubMed ID: 36504862
    [TBL] [Abstract][Full Text] [Related]  

  • 111. A three-dimensional measurement based on CT for the posterior tilt with ideal inter-and intra-observer reliability in non-displaced femoral neck fractures.
    Wu S; Wang W; Zhang B; Zhang H; Xu X; Li G; Shi H; Mei J
    Comput Methods Biomech Biomed Engin; 2021 Dec; 24(16):1854-1861. PubMed ID: 33970714
    [TBL] [Abstract][Full Text] [Related]  

  • 112. To what degree is digital imaging reliable? Validation of femoral neck shaft angle measurement in the era of picture archiving and communication systems.
    Wilson JD; Eardley W; Odak S; Jennings A
    Br J Radiol; 2011 Apr; 84(1000):375-9. PubMed ID: 21159801
    [TBL] [Abstract][Full Text] [Related]  

  • 113. Comparing two different automatic methods to measure femoral neck-shaft angle based on PointNet++ network.
    Li Z; Yang J; Li X; Wang K; Han J; Yang P
    Sci Rep; 2022 Jul; 12(1):12437. PubMed ID: 35858999
    [TBL] [Abstract][Full Text] [Related]  

  • 114. Measurement of femoral axial offset.
    Matsubayashi S; Isobe Y; Chiba K; Tsujimoto R; Osaki M; Imamura T; Tsurumoto T
    J Orthop Res; 2021 Jul; 39(7):1383-1389. PubMed ID: 32876948
    [TBL] [Abstract][Full Text] [Related]  

  • 115. A novel method for quantifying femoral neck anteversion: A case study in extinct and extant sloths.
    Harper CM; Sylvester AD; McAfee RK; Cooke SB
    Anat Rec (Hoboken); 2021 Feb; 304(2):266-278. PubMed ID: 32378312
    [TBL] [Abstract][Full Text] [Related]  

  • 116. [Determining rotational errors of the femur by axial computerized tomography in comparison with clinical and conventional radiologic determination].
    Wissing H; Buddenbrock B
    Unfallchirurgie; 1993 Jun; 19(3):145-57. PubMed ID: 8333078
    [TBL] [Abstract][Full Text] [Related]  

  • 117. Ultrasonographic Assessment of Femoral Torsion Angle Based on Tilting Angles of Femoral Neck and Condylar Axis.
    Takeuchi S; Goto H; Iguchi H; Watanabe N; Osaga S; Murakami H; Yoshida M
    Ultrasound Med Biol; 2019 Aug; 45(8):1970-1976. PubMed ID: 31064699
    [TBL] [Abstract][Full Text] [Related]  

  • 118. Measuring Lateral Screw Protuberance Is a Clinically Accurate Method for Quantifying Femoral Neck Shortening.
    Sepehri A; Martinson J; Marchand LS; Riedel MD; McAlister IP; O'Hara NN; Stockton DJ; Slobogean GP
    J Orthop Trauma; 2020 Nov; 34(11):600-605. PubMed ID: 33065661
    [TBL] [Abstract][Full Text] [Related]  

  • 119. Measurement of anteversion of the femoral neck. Ultrasound and computerised tomography compared.
    Lausten GS; Jørgensen F; Boesen J
    J Bone Joint Surg Br; 1989 Mar; 71(2):237-9. PubMed ID: 2647753
    [TBL] [Abstract][Full Text] [Related]  

  • 120. The Availability of Radiological Measurement of Femoral Anteversion Angle: Three-Dimensional Computed Tomography Reconstruction.
    Byun HY; Shin H; Lee ES; Kong MS; Lee SH; Lee CH
    Ann Rehabil Med; 2016 Apr; 40(2):237-43. PubMed ID: 27152273
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.