  • 21. Evaluation of a portable fundus camera for use in the teleophthalmologic diagnosis of glaucoma.
    Yogesan K; Constable IJ; Barry CJ; Eikelboom RH; Morgan W; Tay-Kearney ML; Jitskaia L
    J Glaucoma; 1999 Oct; 8(5):297-301. PubMed ID: 10529928
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Comparison of the mean deviation of retinal sensitivity in the static perimetry threshold test with biomorphometric parameters of the optic disc in eyes with glaucoma].
    Gierek-Lapińska A; Janiec S; Rzendkowski M; Szymański A; Błazejewska-Meller G
    Klin Oczna; 1997; 99(1):7-10. PubMed ID: 9379658
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Systems for staging the amount of optic nerve damage in glaucoma: a critical review and new material.
    Spaeth GL; Lopes JF; Junk AK; Grigorian AP; Henderer J
    Surv Ophthalmol; 2006; 51(4):293-315. PubMed ID: 16818081
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Detection of optic disc changes with Glaucoma-Scope probability maps.
    Yamada N; Emond MJ; Mills RP; Leen MM; Chen PP; Stanford DC
    J Glaucoma; 1998 Dec; 7(6):378-87. PubMed ID: 9871859
    [TBL] [Abstract][Full Text] [Related]  

  • 25. New glaucoma technology looks beyond visual ability to the site of damage.
    Singer H
    J Ophthalmic Nurs Technol; 1999; 18(5):198-9. PubMed ID: 10847046
    [No Abstract]   [Full Text] [Related]  

  • 26. Automated analysis of normal and glaucomatous optic nerve head topography images.
    Swindale NV; Stjepanovic G; Chin A; Mikelberg FS
    Invest Ophthalmol Vis Sci; 2000 Jun; 41(7):1730-42. PubMed ID: 10845593
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Automated interpretation of optic nerve images: a data mining framework for glaucoma diagnostic support.
    Abidi SS; Artes PH; Yun S; Yu J
    Stud Health Technol Inform; 2007; 129(Pt 2):1309-13. PubMed ID: 17911926
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Longitudinal evaluation of optic disc measurement variability with optical coherence tomography and confocal scanning laser ophthalmoscopy.
    Lin D; Leung CK; Weinreb RN; Cheung CY; Li H; Lam DS
    J Glaucoma; 2009 Feb; 18(2):101-6. PubMed ID: 19225344
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Automated segmentation of the optic nerve head for diagnosis of glaucoma.
    Chrástek R; Wolf M; Donath K; Niemann H; Paulus D; Hothorn T; Lausen B; Lämmer R; Mardin CY; Michelson G
    Med Image Anal; 2005 Aug; 9(4):297-314. PubMed ID: 15950894
    [TBL] [Abstract][Full Text] [Related]  

  • 30. DICOM transmission of simultaneous stereoscopic images of the optic nerve in patients with glaucoma.
    Khouri AS; Szirth BC; Salti HI; Fechtner RD
    J Telemed Telecare; 2007; 13(7):337-40. PubMed ID: 17958934
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Ranking of optic disc variables for detection of glaucomatous optic nerve damage.
    Jonas JB; Bergua A; Schmitz-Valckenberg P; Papastathopoulos KI; Budde WM
    Invest Ophthalmol Vis Sci; 2000 Jun; 41(7):1764-73. PubMed ID: 10845597
    [TBL] [Abstract][Full Text] [Related]  

  • 32. [Glaucoma diagnosis with the GDx and measurement of nerve fibre thickness (RTA)].
    Funk J; Maier P
    Ophthalmologe; 2003 Jan; 100(1):21-7. PubMed ID: 12557022
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Topographic stereoscopic measurements of optic disc in early primary open angle glaucoma].
    Pan Y; Li M
    Zhonghua Yan Ke Za Zhi; 1996 Sep; 32(5):345-9. PubMed ID: 9590825
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Improving glaucoma diagnosis by the combination of perimetry and HRT measurements.
    Mardin CY; Peters A; Horn F; Jünemann AG; Lausen B
    J Glaucoma; 2006 Aug; 15(4):299-305. PubMed ID: 16865006
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Measurement of optic nerve head pallor with a video-ophthalmograph and with computerized boundary analysis.
    Mikelberg FS; Douglas GR; Drance SM; Schulzer M; Schwartz B; Nagin P; Wijsman K
    Can J Ophthalmol; 1988 Apr; 23(3):120-3. PubMed ID: 3285977
    [TBL] [Abstract][Full Text] [Related]  

  • 36. The correlation between optic disk topography measured by the video-ophthalmograph (Rodenstock analyzer) and clinical measurement.
    Mikelberg FS; Airaksinen PJ; Douglas GR; Schulzer M; Wijsman K
    Am J Ophthalmol; 1985 Sep; 100(3):417-9. PubMed ID: 4037028
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Image analysis in glaucoma.
    Cooper RL
    Aust N Z J Ophthalmol; 1997 Aug; 25(3):187-8. PubMed ID: 9296290
    [No Abstract]   [Full Text] [Related]  

  • 38. [Papillometry].
    Rigal D; Veschambre MC; Sole P
    Annee Ther Clin Ophtalmol; 1988; 39():125-30; discussion 141-53. PubMed ID: 3272099
    [No Abstract]   [Full Text] [Related]  

  • 39. Computerized optic disk imaging techniques.
    Beck RW
    Int Ophthalmol Clin; 1986; 26(4):197-200. PubMed ID: 3804628
    [No Abstract]   [Full Text] [Related]  

  • 40. [Glaucoma diagnosis -- photographic analysis].
    Jonas JB
    Ophthalmologe; 2003 Jan; 100(1):3-4. PubMed ID: 12608402