119 related articles for article (PubMed ID: 9253904)
1. Retinal large vessel oxygen saturations correlate with early blood loss and hypoxia in anesthetized swine.
Denninghoff KR; Smith MH; Chipman RA; Hillman LW; Jester PM; Hughes CE; Kuhn F; Rue LW
J Trauma; 1997 Jul; 43(1):29-34. PubMed ID: 9253904
[TBL] [Abstract][Full Text] [Related]
2. Retinal venous oxygen saturation correlates with blood volume.
Denninghoff KR; Smith MH; Hillman LW; Redden D; Rue LW
Acad Emerg Med; 1998 Jun; 5(6):577-82. PubMed ID: 9660283
[TBL] [Abstract][Full Text] [Related]
3. Retinal venous oxygen saturation and cardiac output during controlled hemorrhage and resuscitation.
Denninghoff KR; Smith MH; Lompado A; Hillman LW
J Appl Physiol (1985); 2003 Mar; 94(3):891-6. PubMed ID: 12571124
[TBL] [Abstract][Full Text] [Related]
4. Retinal oximetry and systemic arterial oxygen levels.
Eliasdottir TS
Acta Ophthalmol; 2018 Nov; 96 Suppl A113():1-44. PubMed ID: 30460761
[TBL] [Abstract][Full Text] [Related]
5. Oxygen saturation in intraosseous sternal blood measured by CO-oximetry and evaluated non-invasively during hypovolaemia and hypoxia - a porcine experimental study.
Näslund E; Lindberg LG; Strandberg G; Apelthun C; Franzén S; Frithiof R
J Clin Monit Comput; 2023 Jun; 37(3):847-856. PubMed ID: 36786963
[TBL] [Abstract][Full Text] [Related]
6. Retinal imaging techniques in diabetes.
Denninghoff KR; Smith MH; Hillman L
Diabetes Technol Ther; 2000; 2(1):111-3. PubMed ID: 11467308
[TBL] [Abstract][Full Text] [Related]
7. Mixed venous oxygen saturation and biochemical parameters of hypoxia during progressive hypoxemia in 10- to 14-day-old piglets.
van der Hoeven MA; Maertzdorf WJ; Blanco CE
Pediatr Res; 1997 Dec; 42(6):878-84. PubMed ID: 9396573
[TBL] [Abstract][Full Text] [Related]
8. Retinal oximetry using intravitreal illumination.
Salyer DA; Beaudry N; Basavanthappa S; Twietmeyer K; Eskandari M; Denninghoff KR; Chipman RA; Park RI
Curr Eye Res; 2006; 31(7-8):617-27. PubMed ID: 16877270
[TBL] [Abstract][Full Text] [Related]
9. Retinal oximetry.
Hardarson SH
Acta Ophthalmol; 2013 Mar; 91 Thesis 2():1-47. PubMed ID: 23470088
[TBL] [Abstract][Full Text] [Related]
10. Retinal oximetry measures systemic hypoxia in central nervous system vessels in chronic obstructive pulmonary disease.
Eliasdottir TS; Bragason D; Hardarson SH; Vacchiano C; Gislason T; Kristjansdottir JV; Kristjansdottir G; Stefánsson E
PLoS One; 2017; 12(3):e0174026. PubMed ID: 28328974
[TBL] [Abstract][Full Text] [Related]
11. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
Feiner JR; Bickler PE; Mannheimer PD
Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
[TBL] [Abstract][Full Text] [Related]
12. Relationship between mixed venous oxygen saturation and markers of tissue oxygenation in progressive hypoxic hypoxia and in isovolemic anemic hypoxia in 8- to 12-day-old piglets.
van der Hoeven MA; Maertzdorf WJ; Blanco CE
Crit Care Med; 1999 Sep; 27(9):1885-92. PubMed ID: 10507614
[TBL] [Abstract][Full Text] [Related]
13. The accuracy of a fiberoptic oximeter over a wide range of arterial oxygen saturation values in piglets.
Nijland R; Jongsma HW; Nijhuis JG; Oeseburg B
Acta Anaesthesiol Scand Suppl; 1995; 107():71-6. PubMed ID: 8599303
[TBL] [Abstract][Full Text] [Related]
14. [Comparison of oxygen saturations in mixed venous and central blood during thoracic anesthesia with selective single-lung ventilation].
Herrera A; Pajuelo A; Morano MJ; Ureta MP; Gutiérrez-García J; de las Mulas M
Rev Esp Anestesiol Reanim; 1993; 40(6):349-53. PubMed ID: 8134675
[TBL] [Abstract][Full Text] [Related]
15. Continuous central venous oxygen saturation monitoring under varying physiological conditions in an animal model.
Kissoon N; Spenceley N; Krahn G; Milner R
Anaesth Intensive Care; 2010 Sep; 38(5):883-9. PubMed ID: 20865873
[TBL] [Abstract][Full Text] [Related]
16. Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry.
Van Keer K; Van Keer J; Barbosa Breda J; Nassiri V; De Deyne C; Genbrugge C; Abegão Pinto L; Stalmans I; Vandewalle E
PLoS One; 2018; 13(1):e0190612. PubMed ID: 29304150
[TBL] [Abstract][Full Text] [Related]
17. Continuous, in vivo pulmonary venous admixture from fiberoptically measured hemoglobin saturations.
Kamal GD; Starr JM; Symreng T
Crit Care Med; 1990 Dec; 18(12):1419-22. PubMed ID: 2245618
[TBL] [Abstract][Full Text] [Related]
18. Adequate agreement between venous oxygen saturation in right atrium and pulmonary artery in critically ill children.
Pérez AC; Eulmesekian PG; Minces PG; Schnitzler EJ
Pediatr Crit Care Med; 2009 Jan; 10(1):76-9. PubMed ID: 19057448
[TBL] [Abstract][Full Text] [Related]
19. Noninvasive oximetry in the rat.
Decker MJ; Conrad KP; Strohl KP
Biomed Instrum Technol; 1989; 23(3):222-8. PubMed ID: 2752232
[TBL] [Abstract][Full Text] [Related]
20. Measurement of right atrial oxygen saturation by fiberoptic oximetry accurately reflects mixed venous oxygen saturation in swine.
Davies GG; Mendenhall J; Symreng T
J Clin Monit; 1988 Apr; 4(2):99-102. PubMed ID: 3373256
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]