These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

110 related articles for article (PubMed ID: 925616)

  • 41. [Autoanalysis of blood sugar by means of a glucose oxidase-catalase].
    Motegi K; Shoji K
    Rinsho Byori; 1968 Jul; 16(7):589-93. PubMed ID: 5750557
    [No Abstract]   [Full Text] [Related]  

  • 42. The use of immobilized enzyme reactors in continuous-flow analyzers for the determination of glucose, urea, and uric acid.
    Chirillo R; Caenaro G; Pavan B; Pin A
    Clin Chem; 1979 Oct; 25(10):1744-8. PubMed ID: 476924
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Preparation and characterization of glucose oxidase nanoparticles and their application in dissolved oxygen metric determination of serum glucose.
    Kundu N; Yadav S; Pundir CS
    J Nanosci Nanotechnol; 2013 Mar; 13(3):1710-6. PubMed ID: 23755578
    [TBL] [Abstract][Full Text] [Related]  

  • 44. [Automation in analyses. IV. Determination of glucose and urea in blood by a new automatic method].
    Morisi G; Gualandi G; Ruffini MP
    Ann Ist Super Sanita; 1968; 4(5):602-7. PubMed ID: 5734038
    [No Abstract]   [Full Text] [Related]  

  • 45. [Determination of glucose with glucoseoxidase-UV, using hexokinase as the reference method (author's transl)].
    Koch CD
    J Clin Chem Clin Biochem; 1976 Jul; 14(7):373-4. PubMed ID: 956736
    [TBL] [Abstract][Full Text] [Related]  

  • 46. [Comparative study on GOD-trinder method for measuring glucose in serum with different benzene-original phenols].
    Xu S; Deng J; Xu JS; Yuan YL; Zhang W
    Guang Pu Xue Yu Guang Pu Fen Xi; 2006 Mar; 26(3):526-8. PubMed ID: 16830771
    [TBL] [Abstract][Full Text] [Related]  

  • 47. An examination of the hexokinase method for serum glucose assay using external quality assessment data.
    Westwood A; Bullock DG; Whitehead TP
    Ann Clin Biochem; 1986 Jan; 23 ( Pt 1)():92-6. PubMed ID: 3767257
    [TBL] [Abstract][Full Text] [Related]  

  • 48. An enzymatic fluorometric method for the determination of glucose in plasma.
    Phillips RE; Elevitch FR
    Am J Clin Pathol; 1968 May; 49(5):622-6. PubMed ID: 5660957
    [No Abstract]   [Full Text] [Related]  

  • 49. [Continuous flow measurement of glycemia by the modified Trinder method].
    Seneterre JB; Desermeaux A; Dupoizat H; Roche R
    Ann Biol Clin (Paris); 1977; 35(2):109-16. PubMed ID: 921009
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Automated fluorometric micromethod for blood glucose.
    Seiter CW; Hill HD; Summer GK
    Clin Chem; 1973 Nov; 19(11):1296-9. PubMed ID: 4758606
    [No Abstract]   [Full Text] [Related]  

  • 51. The immobilization of enzymes on nylon structures and their use in automated analysis.
    Inman DJ; Hornby WE
    Biochem J; 1972 Sep; 129(2):255-62. PubMed ID: 4643309
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Automated glucose methods: evaluation of a glucose oxidase-peroxidase procedure.
    Romano AT
    Clin Chem; 1973 Oct; 19(10):1152-7. PubMed ID: 4741954
    [No Abstract]   [Full Text] [Related]  

  • 53. Interlaboratory comparison of enzymatic methods for serum glucose determination.
    Gochman N; Ryan WT; Sterling RE; Widdowson GM
    Clin Chem; 1975 Mar; 21(3):356-61. PubMed ID: 1112045
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Poly(vinyl alcohol) : a potential matrix for glucose oxidase immobilization?
    Azila AA; Barbari T; Searson P
    Med J Malaysia; 2004 May; 59 Suppl B():51-2. PubMed ID: 15468814
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Fluorometric method for quantitative determination of glucose and its application to human serum.
    Gao J; Zhou J; Qu X
    Anal Sci; 2005 Apr; 21(4):409-12. PubMed ID: 15844335
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Diluted glucose oxidase reagents adapted for use with Analox GM 7 Analyser for measuring plasma glucose.
    Loh SH
    Ann Clin Biochem; 1989 Sep; 26 ( Pt 5)():453-4. PubMed ID: 2817758
    [No Abstract]   [Full Text] [Related]  

  • 57. Amperometric, screen-printed, glucose biosensor for analysis of human plasma samples using a biocomposite water-based carbon ink incorporating glucose oxidase.
    Crouch E; Cowell DC; Hoskins S; Pittson RW; Hart JP
    Anal Biochem; 2005 Dec; 347(1):17-23. PubMed ID: 16266677
    [TBL] [Abstract][Full Text] [Related]  

  • 58. [Enzymatic blood sugar determination in vitro and in vivo with the autoanalyzer].
    Kawerau E
    Z Klin Chem Klin Biochem; 1966 Jul; 4(4):224-32. PubMed ID: 5991749
    [No Abstract]   [Full Text] [Related]  

  • 59. Microporous membrane flow cell with nonimmobilized enzyme for chemiluminescent determination of glucose.
    Pilosof D; Nieman TA
    Anal Chem; 1982 Sep; 54(11):1698-701. PubMed ID: 7149258
    [No Abstract]   [Full Text] [Related]  

  • 60. Inaccuracy of test strips with reflectance meter in determination of high blood-sugars.
    Junker K; Ditzel J
    Lancet; 1972 Apr; 1(7755):815-7. PubMed ID: 4111578
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.