165 related articles for article (PubMed ID: 9263390)
1. Interference of oleandrin and oleandrigenin in digitoxin immunoassays: minimal cross reactivity with a new monoclonal chemiluminescent assay and high cross reactivity with the fluorescence polarization assay.
Datta P; Dasgupta A
Ther Drug Monit; 1997 Aug; 19(4):465-9. PubMed ID: 9263390
[TBL] [Abstract][Full Text] [Related]
2. Rapid detection of oleander poisoning using fluorescence polarization immunoassay for digitoxin. Effect of treatment with digoxin-specific Fab antibody fragment (ovine).
Dasgupta A; Hart AP
Am J Clin Pathol; 1997 Oct; 108(4):411-6. PubMed ID: 9322594
[TBL] [Abstract][Full Text] [Related]
3. Neutralization of cardiac toxins oleandrin, oleandrigenin, bufalin, and cinobufotalin by digibind: monitoring the effect by measuring free digitoxin concentrations.
Dasgupta A; Emerson L
Life Sci; 1998; 63(9):781-8. PubMed ID: 9740315
[TBL] [Abstract][Full Text] [Related]
4. Rapid detection of oleander poisoning using digoxin immunoassays: comparison of five assays.
Dasgupta A; Datta P
Ther Drug Monit; 2004 Dec; 26(6):658-63. PubMed ID: 15570191
[TBL] [Abstract][Full Text] [Related]
5. Inhibition of Na,K-ATPase by oleandrin and oleandrigenin, and their detection by digoxin immunoassays.
Jortani SA; Helm RA; Valdes R
Clin Chem; 1996 Oct; 42(10):1654-8. PubMed ID: 8855150
[TBL] [Abstract][Full Text] [Related]
6. Unexpected suppression of total digoxin concentrations by cross-reactants in the microparticle enzyme immunoassay: elimination of interference by monitoring free digoxin concentration.
Dasgupta A; Scott J
Am J Clin Pathol; 1998 Jul; 110(1):78-82. PubMed ID: 9661925
[TBL] [Abstract][Full Text] [Related]
7. Rapid detection of cardioactive bufalin toxicity using fluorescence polarization immunoassay for digitoxin.
Dasgupta A; Datta P
Ther Drug Monit; 1998 Feb; 20(1):104-8. PubMed ID: 9485564
[TBL] [Abstract][Full Text] [Related]
8. Effect of digoxin fab antibody on the measurement of total and free digitoxin by fluorescence polarization and a new chemiluminescent immunoassay.
Dasgupta A; Wells A; Datta P
Ther Drug Monit; 1999 Apr; 21(2):251-5. PubMed ID: 10217348
[TBL] [Abstract][Full Text] [Related]
9. Bidirectional (positive/negative) interference in a digoxin immunoassay: importance of antibody specificity.
Datta P; Dasgupta A
Ther Drug Monit; 1998 Jun; 20(3):352-7. PubMed ID: 9631936
[TBL] [Abstract][Full Text] [Related]
10. Interference from digitoxin-like immunoreactive factors reduced in a new monoclonal chemiluminescent digitoxin assay.
Datta P; Dasgupta A
Ther Drug Monit; 1998 Dec; 20(6):663-8. PubMed ID: 9853984
[TBL] [Abstract][Full Text] [Related]
11. Bidirectional (negative/positive) interference of oleandrin and oleander extract on a relatively new Loci digoxin assay using Vista 1500 analyzer.
Dasgupta A; Welsh KJ; Hwang SA; Johnson M; Actor JK
J Clin Lab Anal; 2014 Jan; 28(1):16-20. PubMed ID: 24375780
[TBL] [Abstract][Full Text] [Related]
12. Falsely elevated serum digitoxin concentrations due to cross-reactivity of water-extractable digitoxin-like immunoreactivity of Chinese medicine Chan SU: elimination of interference by use of a chemiluminescent assay.
Biddle DA; Datta P; Wells A; Dasgupta A
Clin Chim Acta; 2000 Oct; 300(1-2):151-8. PubMed ID: 10958871
[TBL] [Abstract][Full Text] [Related]
13. Determination of thevetin B in serum by fluorescence polarization immunoassay.
Uber-Bucek E; Hamon M; Pham Huy C; Dadoun H
J Pharm Biomed Anal; 1992 Jun; 10(6):413-9. PubMed ID: 1420463
[TBL] [Abstract][Full Text] [Related]
14. Digitoxinlike and digoxinlike immunoreactivitis in sera of patients with uremia and liver disease as measured by fluorescence polarization immunoassays: poor correlation between digitoxinlike and digoxinlike immunoreactivities.
Luke M; Dasgupta A
Ther Drug Monit; 1997 Apr; 19(2):230-5. PubMed ID: 9108656
[TBL] [Abstract][Full Text] [Related]
15. Stability of oleander extract and oleandrin in sera stored in plastic serum separator tubes.
Dasgupta A; White D
Ann Clin Biochem; 2007 Sep; 44(Pt 5):485-7. PubMed ID: 17761037
[TBL] [Abstract][Full Text] [Related]
16. Interference of endogenous digoxin-like immunoreactive factors in serum digoxin measurement is minimized in a new turbidimetric digoxin immunoassay on ADVIA 1650 analyzer.
Datta P; Dasgupta A
Ther Drug Monit; 2004 Feb; 26(1):85-9. PubMed ID: 14749555
[TBL] [Abstract][Full Text] [Related]
17. The new enzyme-linked immunosorbent digoxin assay on the ADVIA Integrated Modular System is virtually free from oleander interference.
Dasgupta A; Kang E; Datta P
Ther Drug Monit; 2006 Apr; 28(2):282-5. PubMed ID: 16628146
[TBL] [Abstract][Full Text] [Related]
18. New enzyme-linked immunosorbent digoxin assay on the ADVIA IMS 800i system is virtually free from interference of endogenous digoxin-like immunoreactive factors.
Dasgupta A; Kang E; Datta P
Ther Drug Monit; 2005 Apr; 27(2):139-43. PubMed ID: 15795642
[TBL] [Abstract][Full Text] [Related]
19. Sensitive methods for determination of free digitoxin concentration using digitoxin immunoassays: demonstration of elevated free digitoxin concentration caused by digitoxin-phenytoin interaction by applying these new techniques.
Dasgupta A; Vega AE; Wells A; Datta P
Ther Drug Monit; 1999 Dec; 21(6):625-30. PubMed ID: 10604823
[TBL] [Abstract][Full Text] [Related]
20. Activated charcoal is effective but equilibrium dialysis is ineffective in removing oleander leaf extract and oleandrin from human serum: monitoring the effect by measuring apparent digoxin concentration.
Dasgupta A; Cao S; Wells A
Ther Drug Monit; 2003 Jun; 25(3):323-30. PubMed ID: 12766561
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]