These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

163 related articles for article (PubMed ID: 9264507)

  • 1. Myocardial perfusion imaging in the setting of coronary artery stenosis and acute myocardial infarction using venous injection of a second-generation echocardiographic contrast agent.
    Firschke C; Lindner JR; Wei K; Goodman NC; Skyba DM; Kaul S
    Circulation; 1997 Aug; 96(3):959-67. PubMed ID: 9264507
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Myocardial perfusion characteristics and hemodynamic profile of MRX-115, a venous echocardiographic contrast agent, during acute myocardial infarction.
    Lindner JR; Firschke C; Wei K; Goodman NC; Skyba DM; Kaul S
    J Am Soc Echocardiogr; 1998 Jan; 11(1):36-46. PubMed ID: 9487468
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of risk area during coronary occlusion and infarct size after reperfusion with myocardial contrast echocardiography using left and right atrial injections of contrast.
    Villanueva FS; Glasheen WP; Sklenar J; Kaul S
    Circulation; 1993 Aug; 88(2):596-604. PubMed ID: 8339423
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of significant two-vessel versus one-vessel coronary artery stenosis on myocardial contrast defects observed with intermittent harmonic imaging after intravenous contrast injection during dobutamine stress echocardiography.
    Porter TR; Li S; Kilzer K; Deligonul U
    J Am Coll Cardiol; 1997 Nov; 30(5):1399-406. PubMed ID: 9350946
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography.
    Leong-Poi H; Le E; Rim SJ; Sakuma T; Kaul S; Wei K
    J Am Soc Echocardiogr; 2001 Dec; 14(12):1173-82. PubMed ID: 11734784
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection of myocardial perfusion defects by contrast echocardiography in the setting of acute myocardial ischemia with residual antegrade flow.
    Main ML; Escobar JF; Hall SA; Killam AL; Grayburn PA
    J Am Soc Echocardiogr; 1998 Mar; 11(3):228-35. PubMed ID: 9560746
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Quantitative assessment of myocardial perfusion during graded coronary artery stenoses by intravenous myocardial contrast echocardiography.
    Leistad E; Ohmori K; Peterson TA; Christensen G; DeMaria AN
    J Am Coll Cardiol; 2001 Feb; 37(2):624-31. PubMed ID: 11216989
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of coronary stenoses and quantification of the degree and spatial extent of blood flow mismatch during coronary hyperemia with myocardial contrast echocardiography.
    Ismail S; Jayaweera AR; Goodman NC; Camarano GP; Skyba DM; Kaul S
    Circulation; 1995 Feb; 91(3):821-30. PubMed ID: 7828311
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noninvasive prediction of ultimate infarct size at the time of acute coronary occlusion based on the extent and magnitude of collateral-derived myocardial blood flow.
    Coggins MP; Sklenar J; Le DE; Wei K; Lindner JR; Kaul S
    Circulation; 2001 Nov; 104(20):2471-7. PubMed ID: 11705827
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemodynamic characteristics, myocardial kinetics and microvascular rheology of FS-069, a second-generation echocardiographic contrast agent capable of producing myocardial opacification from a venous injection.
    Skyba DM; Camarano G; Goodman NC; Price RJ; Skalak TC; Kaul S
    J Am Coll Cardiol; 1996 Nov; 28(5):1292-300. PubMed ID: 8890829
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Detection of coronary stenosis and myocardial viability using a single intravenous bolus injection of BR14.
    Fisher NG; Leong-Poi H; Sakuma T; Rim SJ; Bin JP; Kaul S
    J Am Coll Cardiol; 2002 Feb; 39(3):523-9. PubMed ID: 11823093
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Relation of perfusion defects observed with myocardial contrast echocardiography to the severity of coronary stenosis: correlation with thallium-201 single-photon emission tomography.
    Cheirif J; Desir RM; Bolli R; Mahmarian JJ; Zoghbi WA; Verani MS; QuiƱones MA
    J Am Coll Cardiol; 1992 May; 19(6):1343-9. PubMed ID: 1564236
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion?
    Wei K; Jayaweera AR; Firoozan S; Linka A; Skyba DM; Kaul S
    J Am Coll Cardiol; 1998 Jul; 32(1):252-60. PubMed ID: 9669278
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Assessment of myocardial perfusion with second harmonic imaging--using intravenous injection of Albunex and Levovist].
    Hasegawa M; Saiki Y; Kayano H; Katagiri T
    Nihon Rinsho; 1998 Apr; 56(4):903-8. PubMed ID: 9577606
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of myocardial perfusion by myocardial contrast echocardiography using harmonic power and the transvenous contrast agent SHU 563A in acute coronary occlusion and after reperfusion.
    Teupe C; Takeuchi M; Yao J; Abadi C; Avelar E; Fritzsch T; Pandian N
    Int J Cardiol; 2001 Feb; 77(2-3):231-7. PubMed ID: 11182187
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Contrast echocardiography can assess risk area and infarct size during coronary occlusion and reperfusion: experimental validation.
    Lafitte S; Higashiyama A; Masugata H; Peters B; Strachan M; Kwan OL; DeMaria AN
    J Am Coll Cardiol; 2002 May; 39(9):1546-54. PubMed ID: 11985921
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Myocardial contrast echocardiography with harmonic power Doppler and lung traversing SHU 563A ultrasound contrast medium for imaging myocardial perfusion disorders].
    Teupe C; Yao J; Takeuchi M; Abadi C; Avelar E; Fritzsch T; Pandian N
    Z Kardiol; 2000 Oct; 89(10):914-20. PubMed ID: 11098542
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Quantitative assessment of myocardial perfusion during graded coronary stenosis by real-time myocardial contrast echo refilling curves.
    Masugata H; Peters B; Lafitte S; Strachan GM; Ohmori K; DeMaria AN
    J Am Coll Cardiol; 2001 Jan; 37(1):262-9. PubMed ID: 11153750
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Myocardial contrast echocardiography in acute myocardial infarction using aortic root injections of microbubbles in conjunction with harmonic imaging: potential application in the cardiac catheterization laboratory.
    Firschke C; Lindner JR; Goodman NC; Skyba DM; Wei K; Kaul S
    J Am Coll Cardiol; 1997 Jan; 29(1):207-16. PubMed ID: 8996316
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of the veracity of real-time perfusion, harmonic angio, and ultraharmonic mocardial contrast imaging modes in evaluation of acute myocardial infarction area.
    Xing YQ; Zhang Y; Li DQ; Liu XQ; Li XQ; Zhao CQ; Chen M; Gao HQ
    Chin Med J (Engl); 2006 Feb; 119(3):179-84. PubMed ID: 16537001
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.