7. Variation of inhaled nitric oxide concentration with the use of a continuous flow ventilator. De Jaegere AP; Jacobs FI; Laheij NG; van den Anker JN Crit Care Med; 1997 Jun; 25(6):995-1002. PubMed ID: 9201053 [TBL] [Abstract][Full Text] [Related]
8. Distribution of inhaled nitric oxide during sequential and continuous administration into the inspiratory limb of the ventilator. Mourgeon E; Gallart L; Rao GS; Lu Q; Law-Koune JD; Puybasset L; Coriat P; Rouby JJ Intensive Care Med; 1997 Aug; 23(8):849-58. PubMed ID: 9310802 [TBL] [Abstract][Full Text] [Related]
9. Performance of proportional and continuous nitric oxide delivery systems during pressure- and volume-controlled ventilation. Hiesmayr MJ; Neugebauer T; Lassnigg A; Steltzer H; Haider W; Gilly H Br J Anaesth; 1998 Oct; 81(4):544-52. PubMed ID: 9924230 [TBL] [Abstract][Full Text] [Related]
10. A delivery system for inhalation of nitric oxide evaluated with chemiluminescence, electrochemical fuel cells, and capnography. Lindberg L; Rydgren G; Larsson A; Olsson SG; Nordström L Crit Care Med; 1997 Jan; 25(1):190-6. PubMed ID: 8989197 [TBL] [Abstract][Full Text] [Related]
11. Intratracheal pulmonary ventilation in a rabbit lung injury model: continuous airway pressure monitoring and gas exchange efficacy. Hon EK; Hultquist KA; Loescher T; Raszynski A; Torbati D; Tabares C; Wolfsdorf J Crit Care Med; 2000 Jul; 28(7):2480-5. PubMed ID: 10921582 [TBL] [Abstract][Full Text] [Related]
12. Flow-proportional administration of nitric oxide with a new delivery system: inspiratory nitric oxide concentration fluctuation during different flow conditions. Sydow M; Bristow F; Zinserling J; Allen SJ Chest; 1997 Aug; 112(2):496-504. PubMed ID: 9266890 [TBL] [Abstract][Full Text] [Related]
13. Delivery of inhaled nitric oxide using the Ohmeda INOvent Delivery System. Kirmse M; Hess D; Fujino Y; Kacmarek RM; Hurford WE Chest; 1998 Jun; 113(6):1650-7. PubMed ID: 9631807 [TBL] [Abstract][Full Text] [Related]
14. Nitric oxide delivery to the lung: a model. Jones PR; Hooper RH; Stopp N; Moore NA Eur J Anaesthesiol; 2000 Mar; 17(3):160-7. PubMed ID: 10758464 [TBL] [Abstract][Full Text] [Related]
15. Influence of inspiratory flow pattern and nebulizer position on aerosol delivery with a vibrating-mesh nebulizer during invasive mechanical ventilation: an in vitro analysis. Dugernier J; Wittebole X; Roeseler J; Michotte JB; Sottiaux T; Dugernier T; Laterre PF; Reychler G J Aerosol Med Pulm Drug Deliv; 2015 Jun; 28(3):229-36. PubMed ID: 25393556 [TBL] [Abstract][Full Text] [Related]
16. An injection and mixing element for delivery and monitoring of inhaled nitric oxide. Martin AR; Jackson C; Fromont S; Pont C; Katz IM; Caillobotte G Biomed Eng Online; 2016 Aug; 15(1):103. PubMed ID: 27576350 [TBL] [Abstract][Full Text] [Related]