These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Use of electrosurgical units in the endoscopic resection of gastrointestinal tumors. Marín-Gabriel JC; Romito R; Guarner-Argente C; Santiago-García J; Rodríguez-Sánchez J; Toyonaga T Gastroenterol Hepatol; 2019 Oct; 42(8):512-523. PubMed ID: 31326105 [TBL] [Abstract][Full Text] [Related]
5. Obtaining rapid and effective hemostasis: Part II. Electrosurgery in patients with implantable cardiac devices. Howe N; Cherpelis B J Am Acad Dermatol; 2013 Nov; 69(5):677.e1-677.e9. PubMed ID: 24124835 [TBL] [Abstract][Full Text] [Related]
6. Intraoperative Electrosurgical Electromagnetic Interference in Patients with Implantable Cardioverter Defibrillators: Is It Safe? Rooke GA Anesthesiology; 2019 Apr; 130(4):523-525. PubMed ID: 30724773 [No Abstract] [Full Text] [Related]
7. Electrosurgery in patients with implantable electronic cardiac devices (pacemakers and defibrillators). García Bracamonte B; Rodriguez J; Casado R; Vanaclocha F Actas Dermosifiliogr; 2013 Mar; 104(2):128-32. PubMed ID: 23218607 [TBL] [Abstract][Full Text] [Related]
8. Electrosurgery and implantable electronic devices: review and implications for office-based procedures. Voutsalath MA; Bichakjian CK; Pelosi F; Blum D; Johnson TM; Farrehi PM Dermatol Surg; 2011 Jul; 37(7):889-99. PubMed ID: 21585593 [No Abstract] [Full Text] [Related]
9. Electrosurgery in patients with pacemakers/implanted cardioverter defibrillators. Dawes JC; Mahabir RC; Hillier K; Cassidy M; de Haas W; Gillis AM Ann Plast Surg; 2006 Jul; 57(1):33-6. PubMed ID: 16799305 [TBL] [Abstract][Full Text] [Related]
10. Electrosurgery and Implantable Devices: A Survey of Dermatologic Surgeons. Cervantes JA; Fox MC; Jambusaria-Pahlajani A Dermatol Surg; 2021 Jul; 47(7):1029-1030. PubMed ID: 33165061 [No Abstract] [Full Text] [Related]
11. Electrosurgery in otolaryngology-head and neck surgery: principles, advances, and complications. Smith TL; Smith JM Laryngoscope; 2001 May; 111(5):769-80. PubMed ID: 11359154 [TBL] [Abstract][Full Text] [Related]
12. Implications of pacemakers and implantable cardioverter defibrillators in urological practice. Ubee SS; Kasi VS; Bello D; Manikandan R J Urol; 2011 Oct; 186(4):1198-205. PubMed ID: 21849189 [TBL] [Abstract][Full Text] [Related]
13. An update on the management of implanted cardiac devices during electrosurgical procedures. Parekh PJ; Buerlein RC; Shams R; Herre J; Johnson DA Gastrointest Endosc; 2013 Dec; 78(6):836-841. PubMed ID: 24139080 [TBL] [Abstract][Full Text] [Related]
14. Evaluating the effects of different dental devices on implantable cardioverter defibrillators. Maheshwari KR; Nikdel K; Guillaume G; Letra AM; Silva RM; Dorn SO J Endod; 2015 May; 41(5):692-5. PubMed ID: 25726385 [TBL] [Abstract][Full Text] [Related]
15. Implantable Devices: Assessment and Perioperative Management. Costa A; Richman DC Anesthesiol Clin; 2016 Mar; 34(1):185-99. PubMed ID: 26927747 [TBL] [Abstract][Full Text] [Related]
16. Investigation of hyfrecators and their in vitro interference with implantable cardiac devices. Weyer C; Siegle RJ; Eng GG Dermatol Surg; 2012 Nov; 38(11):1843-8. PubMed ID: 22889152 [TBL] [Abstract][Full Text] [Related]
17. Are patients with cardiac implants protected against electromagnetic interference in daily life and occupational environment? Napp A; Stunder D; Maytin M; Kraus T; Marx N; Driessen S Eur Heart J; 2015 Jul; 36(28):1798-804. PubMed ID: 25908772 [TBL] [Abstract][Full Text] [Related]