These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
638 related articles for article (PubMed ID: 9280931)
1. [Magnetic resonance of the brain: comparative assessment of conventional sequences versus fast sequences]. Cardone G; Gallucci M; Paluello GB; Gagliardo O; Castrucci M Radiol Med; 1997 May; 93(5):514-9. PubMed ID: 9280931 [TBL] [Abstract][Full Text] [Related]
2. [Magnetic resonance study of patellofemoral cartilage with a fat-suppressed T1-3D gradient-echo sequence: a comparison with other acquisition technics at medium field strength]. Cardone G; Minio Paluello GB; Lo Presti G; Gagliardo O; Gallucci M; Castrucci M Radiol Med; 1997 Sep; 94(3):150-6. PubMed ID: 9446117 [TBL] [Abstract][Full Text] [Related]
3. [Phased-array superficial coil and breath holding technique in MRI of the liver. Comparison of conventional spin echo sequences with rapid fat suppressing gradient echo and turbo-spin sequences]. Helmberger T; Holzknecht N; Lackerbauer CA; Müller-Lisse U; Schnarkowski P; Gauger J; Reiser M Radiologe; 1995 Dec; 35(12):919-24. PubMed ID: 8584635 [TBL] [Abstract][Full Text] [Related]
4. [Comparison of fast turbo-spin-echo and gradient- and spin-echo sequences as well as echo planar imaging with conventional spin-echo sequences in MRI of focal liver lesions at 1.0 tesla]. Jung G; Krahe T; Kugel H; Gieseke J; Walter C; Fischbach R; Landwehr P Rofo; 1996 Aug; 165(2):137-43. PubMed ID: 8924665 [TBL] [Abstract][Full Text] [Related]
5. Importance of T2*-weighted gradient-echo MRI for diagnosis of cortical vein thrombosis. Fellner FA; Fellner C; Aichner FT; Mölzer G Eur J Radiol; 2005 Nov; 56(2):235-9. PubMed ID: 15967621 [TBL] [Abstract][Full Text] [Related]
6. [Comparison of a T1-weighted inversion-recovery-, gradient-echo- and spin-echo sequence for imaging of the brain at 3.0 Tesla]. Stehling C; Niederstadt T; Krämer S; Kugel H; Schwindt W; Heindel W; Bachmann R Rofo; 2005 Apr; 177(4):536-42. PubMed ID: 15838759 [TBL] [Abstract][Full Text] [Related]
7. [Value of turbo-spin-echo sequences in cerebral magnetic resonance tomography in children]. Kreft B; Kuhl C; Keller E; Schömer M; Haghir-Schömer M; Gieseke J; Haverkamp F; Schild H Rofo; 1995 Aug; 163(2):134-40. PubMed ID: 7670014 [TBL] [Abstract][Full Text] [Related]
8. [Comparative assessment of conventional spin echo sequences and turbo spin echo in the study with magnetic resonance of the lesions of the spinal cord]. Aprile I; Biasizzo E; Petralia B; Iaiza F; De Colle MC; Santino P; Fabris G Radiol Med; 1996 Oct; 92(4):377-80. PubMed ID: 9045235 [TBL] [Abstract][Full Text] [Related]
9. [An introduction to fast and ultrafast sequences in magnetic resonance]. Maspes F; Apruzzese A; Squillaci E; Floris R; Santino P; Simonetti G Radiol Med; 1994 Sep; 88(3):249-58. PubMed ID: 7938731 [TBL] [Abstract][Full Text] [Related]
10. Fast spin-echo imaging of the brain. Jolesz FA; Jones KM Top Magn Reson Imaging; 1993; 5(1):1-13. PubMed ID: 8416684 [TBL] [Abstract][Full Text] [Related]
11. Contrast-enhanced multi-shot echo-planar FLAIR in the depiction of metastatic tumors of the brain: comparison with contrast-enhanced spin-echo T1-weighted imaging. Tomura N; Narita K; Takahashi S; Otani T; Sakuma I; Yasuda K; Nishii T; Watarai J Acta Radiol; 2007 Nov; 48(9):1032-7. PubMed ID: 17957522 [TBL] [Abstract][Full Text] [Related]
12. Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging. Erdem LO; Erdem CZ; Acikgoz B; Gundogdu S Eur J Radiol; 2005 Aug; 55(2):277-82. PubMed ID: 16036160 [TBL] [Abstract][Full Text] [Related]
13. Rapid MR imaging of the liver: comparison of twelve techniques for single breath-hold whole volume acquisition. Naganawa S; Jenner G; Cooper TG; Potchen EJ; Ishigaki T Radiat Med; 1994; 12(6):255-61. PubMed ID: 7724816 [TBL] [Abstract][Full Text] [Related]
14. [Evaluation of rapid gradient-echo and turbo-spin-echo sequences in MRT of focal liver lesions using 0.5 tesla]. Kreft B; Layer G; Spiller L; Träber F; Wolff M; Gieseke J; Steudel A Rofo; 1994 Dec; 161(6):512-8. PubMed ID: 7803774 [TBL] [Abstract][Full Text] [Related]
15. Contrast-enhanced T1-weighted fluid-attenuated inversion-recovery BLADE magnetic resonance imaging of the brain: an alternative to spin-echo technique for detection of brain lesions in the unsedated pediatric patient? Alibek S; Adamietz B; Cavallaro A; Stemmer A; Anders K; Kramer M; Bautz W; Staatz G Acad Radiol; 2008 Aug; 15(8):986-95. PubMed ID: 18620119 [TBL] [Abstract][Full Text] [Related]
16. T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: a comparison in 20 patients with brain lesions. Al-Saeed O; Ismail M; Athyal RP; Rudwan M; Khafajee S J Med Imaging Radiat Oncol; 2009 Aug; 53(4):366-72. PubMed ID: 19695043 [TBL] [Abstract][Full Text] [Related]
17. [Fast and ultra-fast sequences in MRI of the pelvis and retroperitoneum]. Heuck A; Scheidler J; Holzknecht N; Gauger J; Sittek H; Müller-Lisse U; Reiser M Radiologe; 1995 Dec; 35(12):936-44. PubMed ID: 8584637 [TBL] [Abstract][Full Text] [Related]
18. Improved contrast of enhancing brain lesions using contrast-enhanced T1-weighted fast spin-echo MR imaging. Melhem ER; Guidone PL; Jara H; Yucel EK AJR Am J Roentgenol; 1997 Apr; 168(4):1091-5. PubMed ID: 9124121 [TBL] [Abstract][Full Text] [Related]