These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
148 related articles for article (PubMed ID: 9283965)
1. Shapes and dimensional characteristics of polyethylene wear particles generated in vivo by total knee replacements compared to total hip replacements. Schmalzried TP; Campbell P; Schmitt AK; Brown IC; Amstutz HC J Biomed Mater Res; 1997; 38(3):203-10. PubMed ID: 9283965 [TBL] [Abstract][Full Text] [Related]
2. Standardized analysis of UHMWPE wear particles from failed total joint arthroplasties. Mabrey JD; Afsar-Keshmiri A; Engh GA; Sychterz CJ; Wirth MA; Rockwood CA; Agrawal CM J Biomed Mater Res; 2002; 63(5):475-83. PubMed ID: 12209890 [TBL] [Abstract][Full Text] [Related]
3. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. Urban RM; Jacobs JJ; Tomlinson MJ; Gavrilovic J; Black J; Peoc'h M J Bone Joint Surg Am; 2000 Apr; 82(4):457-76. PubMed ID: 10761937 [TBL] [Abstract][Full Text] [Related]
4. Wear and morphology of ultra-high molecular weight polyethylene wear particles from total hip replacements. Campbell P; Doorn P; Dorey F; Amstutz HC Proc Inst Mech Eng H; 1996; 210(3):167-74. PubMed ID: 8885653 [TBL] [Abstract][Full Text] [Related]
5. Isolation and characterization of UHMWPE wear particles down to ten nanometers in size from in vitro hip and knee joint simulators. Tipper JL; Galvin AL; Williams S; McEwen HM; Stone MH; Ingham E; Fisher J J Biomed Mater Res A; 2006 Sep; 78(3):473-80. PubMed ID: 16721797 [TBL] [Abstract][Full Text] [Related]
6. The origin of submicron polyethylene wear debris in total hip arthroplasty. McKellop HA; Campbell P; Park SH; Schmalzried TP; Grigoris P; Amstutz HC; Sarmiento A Clin Orthop Relat Res; 1995 Feb; (311):3-20. PubMed ID: 7634588 [TBL] [Abstract][Full Text] [Related]
8. In vivo comparison of wear particles between highly crosslinked polyethylene and conventional polyethylene in the same design of total knee arthroplasties. Iwakiri K; Minoda Y; Kobayashi A; Sugama R; Iwaki H; Inori F; Hashimoto Y; Ohashi H; Ohta Y; Fukunaga K; Takaoka K J Biomed Mater Res B Appl Biomater; 2009 Nov; 91(2):799-804. PubMed ID: 19637367 [TBL] [Abstract][Full Text] [Related]
10. Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses. Schmalzried TP; Jasty M; Rosenberg A; Harris WH J Appl Biomater; 1994; 5(3):185-90. PubMed ID: 10147443 [TBL] [Abstract][Full Text] [Related]
11. Distribution of polyethylene wear particles and bone fragments in periprosthetic tissue around total hip joint replacements. Zolotarevova E; Entlicher G; Pavlova E; Slouf M; Pokorny D; Vesely F; Gallo J; Sosna A Acta Biomater; 2010 Sep; 6(9):3595-600. PubMed ID: 20417318 [TBL] [Abstract][Full Text] [Related]
12. Polyethylene wear particle generation in vivo in an alumina medial pivot total knee prosthesis. Minoda Y; Kobayashi A; Iwaki H; Miyaguchi M; Kadoya Y; Ohashi H; Takaoka K Biomaterials; 2005 Oct; 26(30):6034-40. PubMed ID: 15893371 [TBL] [Abstract][Full Text] [Related]
13. Comparison and quantitation of wear debris of failed total hip and total knee arthroplasty. Hirakawa K; Bauer TW; Stulberg BN; Wilde AH J Biomed Mater Res; 1996 Jun; 31(2):257-63. PubMed ID: 8731215 [TBL] [Abstract][Full Text] [Related]
14. Separation and characterization of polyethylene wear debris from synovial fluid and tissue samples of revised knee replacements. Wolfarth DL; Han DW; Bushar G; Parks NL J Biomed Mater Res; 1997 Jan; 34(1):57-61. PubMed ID: 8978653 [TBL] [Abstract][Full Text] [Related]
15. Quantitative analysis of ultrahigh molecular weight polyethylene (UHMWPE) wear debris associated with total knee replacements. Shanbhag AS; Bailey HO; Hwang DS; Cha CW; Eror NG; Rubash HE J Biomed Mater Res; 2000; 53(1):100-10. PubMed ID: 10634959 [TBL] [Abstract][Full Text] [Related]
16. Quantitative and qualitative analysis of polyethylene wear particles in synovial fluid of patients with total knee arthroplasty. A preliminary report. Bosco J; Benjamin J; Wallace D Clin Orthop Relat Res; 1994 Dec; (309):11-9. PubMed ID: 7994947 [TBL] [Abstract][Full Text] [Related]
17. Characteristics of Hylamer polyethylene particles isolated from peri-prosthetic tissues of failed cemented total hip arthroplasties. Iwakiri K; Iwaki H; Kobayashi A; Minoda Y; Kagiyama H; Kadoya Y; Takaoka K J Biomed Mater Res B Appl Biomater; 2008 Apr; 85(1):125-9. PubMed ID: 17806109 [TBL] [Abstract][Full Text] [Related]
18. Application of numerical descriptors to the characterization of wear particles obtained from joint replacements. Stachowiak GW; Stachowiak GB; Campbell P Proc Inst Mech Eng H; 1997; 211(1):1-10. PubMed ID: 9141885 [TBL] [Abstract][Full Text] [Related]
19. Influence of design and bearing material on polyethylene wear particle generation in total knee replacement. Utzschneider S; Paulus A; Datz JC; Schroeder C; Sievers B; Wegener B; Jansson V Acta Biomater; 2009 Sep; 5(7):2495-502. PubMed ID: 19375997 [TBL] [Abstract][Full Text] [Related]
20. Particle size and morphology of UHMWPE wear debris in failed total knee arthroplasties--a comparison between mobile bearing and fixed bearing knees. Huang CH; Ho FY; Ma HM; Yang CT; Liau JJ; Kao HC; Young TH; Cheng CK J Orthop Res; 2002 Sep; 20(5):1038-41. PubMed ID: 12382971 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]