These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 9285605)

  • 1. Evaluation with evoked and spontaneous electromyography during lumbar instrumentation: a prospective study.
    Welch WC; Rose RD; Balzer JR; Jacobs GB
    J Neurosurg; 1997 Sep; 87(3):397-402. PubMed ID: 9285605
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of intraoperative neurophysiologic monitoring in lumbosacral spine fusion and instrumentation: a retrospective study.
    Alemo S; Sayadipour A
    World Neurosurg; 2010 Jan; 73(1):72-6; discussion e7. PubMed ID: 20452872
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Neuromonitoring with pulse-train stimulation for implantation of thoracic pedicle screws: a blinded and randomized clinical study. Part 2. The role of feedback.
    Calancie B; Donohue ML; Moquin RR
    J Neurosurg Spine; 2014 Jun; 20(6):692-704. PubMed ID: 24684176
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Ability of electromyographic monitoring to determine the presence of malpositioned pedicle screws in the lumbosacral spine: analysis of 2450 consecutively placed screws.
    Parker SL; Amin AG; Farber SH; McGirt MJ; Sciubba DM; Wolinsky JP; Bydon A; Gokaslan ZL; Witham TF
    J Neurosurg Spine; 2011 Aug; 15(2):130-5. PubMed ID: 21529126
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neuromonitoring with pulse-train stimulation for implantation of thoracic pedicle screws: a blinded and randomized clinical study. Part 1. Methods and alarm criteria.
    Calancie B; Donohue ML; Harris CB; Canute GW; Singla A; Wilcoxen KG; Moquin RR
    J Neurosurg Spine; 2014 Jun; 20(6):675-91. PubMed ID: 24684171
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Neurophysiologic monitoring of spinal nerve root function during instrumented posterior lumbar spine surgery.
    Bose B; Wierzbowski LR; Sestokas AK
    Spine (Phila Pa 1976); 2002 Jul; 27(13):1444-50. PubMed ID: 12131744
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Pulse-train stimulation for detecting medial malpositioning of thoracic pedicle screws.
    Donohue ML; Murtagh-Schaffer C; Basta J; Moquin RR; Bashir A; Calancie B
    Spine (Phila Pa 1976); 2008 May; 33(12):E378-85. PubMed ID: 18496333
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [First experience of intraoperative nerve root monitoring with the INS-1-device on the lumbosacral spine].
    Heyde CE; Böhm H; el-Saghir H; Kayser R
    Z Orthop Ihre Grenzgeb; 2003; 141(1):79-85. PubMed ID: 12605335
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of a commercially made pedicle stimulating probe with a custom-made device: does the commercial device detect pedicle wall breaches more reliably?
    Hedden DM; Norton JA
    Spine (Phila Pa 1976); 2011 Oct; 36(22):1864-6. PubMed ID: 21270697
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels.
    Isley MR; Zhang XF; Balzer JR; Leppanen RE
    Neurodiagn J; 2012 Jun; 52(2):100-75. PubMed ID: 22808751
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Persistently electrified pedicle stimulation instruments in spinal instrumentation. Technique and protocol development.
    Rose RD; Welch WC; Balzer JR; Jacobs GB
    Spine (Phila Pa 1976); 1997 Feb; 22(3):334-43. PubMed ID: 9051896
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intraoperative neuromonitoring: can the results of direct stimulation of titanium-alloy pedicle screws in the thoracic spine be trusted?
    Donohue ML; Swaminathan V; Gilbert JL; Fox CW; Smale J; Moquin RR; Calancie B
    J Clin Neurophysiol; 2012 Dec; 29(6):502-8. PubMed ID: 23207589
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Electrical stimulation for intraoperative evaluation of thoracic pedicle screw placement.
    Shi YB; Binette M; Martin WH; Pearson JM; Hart RA
    Spine (Phila Pa 1976); 2003 Mar; 28(6):595-601. PubMed ID: 12642768
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Using triggered electromyographic threshold in the intercostal muscles to evaluate the accuracy of upper thoracic pedicle screw placement (T3-T6).
    Rodriguez-Olaverri JC; Zimick NC; Merola A; De Blas G; Burgos J; Piza-Vallespir G; Hevia E; Vicente J; Sanper I; Domenech P; Regidor I
    Spine (Phila Pa 1976); 2008 Apr; 33(7):E194-7. PubMed ID: 18379388
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Guideline update for the performance of fusion procedures for degenerative disease of the lumbar spine. Part 15: electrophysiological monitoring and lumbar fusion.
    Sharan A; Groff MW; Dailey AT; Ghogawala Z; Resnick DK; Watters WC; Mummaneni PV; Choudhri TF; Eck JC; Wang JC; Dhall SS; Kaiser MG
    J Neurosurg Spine; 2014 Jul; 21(1):102-5. PubMed ID: 24980592
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Recording diffusion responses from contralateral intercostal muscles after stimulus-triggered electromyography: refining a tool for the assessment of thoracic pedicle screw placement in an experimental porcine model.
    de Blas G; Burgos J; Regidor I; Barrios C; Solá R; García-Urquiza S; Hevia E
    Spine (Phila Pa 1976); 2009 May; 34(11):E391-6. PubMed ID: 19444052
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated intraoperative EMG testing during percutaneous pedicle screw placement.
    Ozgur BM; Berta S; Khiatani V; Taylor WR
    Spine J; 2006; 6(6):708-13. PubMed ID: 17088202
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Efficacy of intraoperative monitoring of transcranial electrical stimulation-induced motor evoked potentials and spontaneous electromyography activity to identify acute-versus delayed-onset C-5 nerve root palsy during cervical spine surgery: clinical article.
    Bhalodia VM; Schwartz DM; Sestokas AK; Bloomgarden G; Arkins T; Tomak P; Gorelick J; Wijesekera S; Beiner J; Goodrich I
    J Neurosurg Spine; 2013 Oct; 19(4):395-402. PubMed ID: 23889183
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Safe pedicle screw placement in thoracic scoliotic curves using t-EMG: stimulation threshold variability at concavity and convexity in apex segments.
    de Blas G; Barrios C; Regidor I; Montes E; Burgos J; Pizá-Vallespir G; Hevia E
    Spine (Phila Pa 1976); 2012 Mar; 37(6):E387-95. PubMed ID: 22024903
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The risks of pedicle wall breech with larger screws after undertapping.
    Chin KR; Gibson B
    Spine J; 2007; 7(5):570-4. PubMed ID: 17905319
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.