These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
26. Sensitivity of radiographic screens to scattered radiation and its relationship to image contrast. Castle JW Radiology; 1977 Mar; 122(3):805-9. PubMed ID: 841075 [TBL] [Abstract][Full Text] [Related]
27. X-ray-intensifying screen technology for improving veterinary field radiography. Pharr JW; Fretz PB J Am Vet Med Assoc; 1979 Nov; 175(10):1103-5. PubMed ID: 521355 [TBL] [Abstract][Full Text] [Related]
28. The AAPM/RSNA physics tutorial for residents. Measures of screen-film performance. Haus AG Radiographics; 1996 Sep; 16(5):1165-81. PubMed ID: 8888396 [TBL] [Abstract][Full Text] [Related]
29. The effect of phosphor K x-rays on the MFT of rare-earth screens. Arnold BA; Bjärngard BE Med Phys; 1979; 6(6):500-3. PubMed ID: 545119 [TBL] [Abstract][Full Text] [Related]
30. Performance of automatic exposure controls when used with rare-earth intensifying screens. Olson A; High M Radiology; 1981 Aug; 140(2):491-8. PubMed ID: 7255727 [TBL] [Abstract][Full Text] [Related]
31. Backscatter from metal surfaces in diagnostic radiology. Kodera Y; Schmidt RA; Chan HP; Doi K Radiology; 1984 Jan; 150(1):231-4. PubMed ID: 6689765 [TBL] [Abstract][Full Text] [Related]
32. Binary screen detector system for single-pulse dual-energy radiography. Boone JM; Tecotzky M; Alexander GM Radiology; 1992 Jun; 183(3):863-70. PubMed ID: 1584948 [TBL] [Abstract][Full Text] [Related]
33. Metal screen-film detector MTF at megavoltage x-ray energies. Droege RT; Bjärngard BE Med Phys; 1979; 6(6):515-8. PubMed ID: 545122 [TBL] [Abstract][Full Text] [Related]
34. Measurements of reciprocity law failure in green-sensitive X-ray films. Arnold BA; Eisenberg H; Bjärngard BE Radiology; 1978 Feb; 126(2):493-8. PubMed ID: 622504 [TBL] [Abstract][Full Text] [Related]
35. Radiologic exchange. Patient dose can be reduced by using 105 mm photofluoro spot films instead of the screen-film cassette spot radiographs. Stears JG; Gray JE; Frank ED Radiol Technol; 1989; 60(6):515-6. PubMed ID: 2762541 [No Abstract] [Full Text] [Related]
36. An asymmetric screen pair for angiography. Moore WE; Cromwell LD Radiology; 1980 Sep; 136(3):787-8. PubMed ID: 7403563 [TBL] [Abstract][Full Text] [Related]
37. [Examinations of rare-earth film-screen-systems for image detectors in mammography (author's transl)]. Weberling R Rontgenblatter; 1979 Mar; 32(3):109-16. PubMed ID: 432483 [TBL] [Abstract][Full Text] [Related]
38. [Reduction of patient dose with maximum assurance of image quality]. Kuhn H Rontgenblatter; 1985 Jul; 38(7):224-30. PubMed ID: 4035266 [TBL] [Abstract][Full Text] [Related]
39. [The importance of high-speed screen-filmcombinations for coronary angiography (author's transl)]. Bardach G Rontgenblatter; 1977 Jun; 30(6):320-4. PubMed ID: 897517 [TBL] [Abstract][Full Text] [Related]
40. [Quality assurance through constancy control for x-ray film processors (author's transl)]. Weberling R Rontgenblatter; 1982 Jun; 35(6):248-54. PubMed ID: 7089438 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]