These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

90 related articles for article (PubMed ID: 9298354)

  • 61. Harmonization Status of Serum Ferritin Measurements and Implications for Use as Marker of Iron-Related Disorders.
    Braga F; Pasqualetti S; Frusciante E; Borrillo F; Chibireva M; Panteghini M
    Clin Chem; 2022 Sep; 68(9):1202-1210. PubMed ID: 35794075
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Reference values and methods comparison of a new testosterone assay on the AxSYM system.
    González-Sagrado M; Martín-Gil FJ; López-Hernández S; Fernández-García N; Olmos-Linares A; Arranz-Peña ML
    Clin Biochem; 2000 Apr; 33(3):175-9. PubMed ID: 10913514
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Assessment of analytical bias in ferritin assays and impact on functional reference limits.
    Choy KW; Sezgin G; Wijeratne N; Calleja J; Liwayan R; Rathnayake G; McFarlane R; McNeil A; Doery JCG; Lu Z; Markus C; Loh TP
    Pathology; 2022 Apr; 54(3):302-307. PubMed ID: 34538480
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Protein measurement of standards for serum ferritin assays, and comparison of liver and spleen ferritins as standards.
    Gonyea-Stewart L; Arndt CH
    Clin Chem; 1979 Jul; 25(7):1344-6. PubMed ID: 455667
    [No Abstract]   [Full Text] [Related]  

  • 65. WHO international cytokine standards and reference preparations.
    Tovey MG; Wadhwa M; Thorpe R
    J Leukoc Biol; 2010 Sep; 88(3):425-6. PubMed ID: 20807711
    [No Abstract]   [Full Text] [Related]  

  • 66. Microparticle enzyme immunoassays for creatine kinase MB and ferritin on the Abbott AxSYM system.
    Simondsen R; Sebek L; Moster J; Osikowicz G; Brandt D
    Clin Chem; 1993 Sep; 39(9):1979. PubMed ID: 8375084
    [No Abstract]   [Full Text] [Related]  

  • 67. An evaluation of the Abbott TDx serum cortisol assay.
    Ayers GJ; Clark J; Burnett D
    Ann Clin Biochem; 1989 May; 26 ( Pt 3)():294-5. PubMed ID: 2764476
    [No Abstract]   [Full Text] [Related]  

  • 68. [Preparation of ferritin from human liver].
    MENDE HE; SUNDERMANN A
    Folia Haematol Int Mag Klin Morphol Blutforsch; 1961; 78():54-64. PubMed ID: 13769340
    [No Abstract]   [Full Text] [Related]  

  • 69. Analytical magnetapheresis of ferritin-labeled lymphocytes.
    Zborowski M; Fuh CB; Green R; Sun L; Chalmers JJ
    Anal Chem; 1995 Oct; 67(20):3702-12. PubMed ID: 8644920
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Evaluation of a commercially obtainable ferritin test kit in relation to the high-dose parabolic phenomenon.
    Li PK; Humbert JR; Cheng CS
    Clin Chem; 1978 Sep; 24(9):1650-1. PubMed ID: 688633
    [No Abstract]   [Full Text] [Related]  

  • 71. [Determination of ferritin in the medical laboratory].
    Burger EC; Zyman HJ; Bauer K; Gabl F
    Med Lab (Stuttg); 1979 Jul; 32(7):165-9. PubMed ID: 470803
    [No Abstract]   [Full Text] [Related]  

  • 72. Reference interval of ferritin in premenopausal women calculated in four laboratories using three different analyzers.
    Dorizzi RM; Fortunato A; Marchi G; Scattolo N
    Clin Biochem; 2000 Feb; 33(1):75-7. PubMed ID: 10693990
    [No Abstract]   [Full Text] [Related]  

  • 73. Lack of ferritin concentration at the decision level among commercial quality-control materials.
    Ng RH; Statland BE
    Clin Chem; 1983 Mar; 29(3):580. PubMed ID: 6825285
    [No Abstract]   [Full Text] [Related]  

  • 74. Development and multisite evaluation of an automated assay for B12 on the Abbott AxSYM analyzer.
    Wilson DH; Yu J; Karian A; Kozlowski J; O'Reilly S
    Clin Chem; 1999 Mar; 45(3):428-9. PubMed ID: 10053053
    [No Abstract]   [Full Text] [Related]  

  • 75. What information should manufacturers provide on their procedures?
    Bais R
    Clin Chem; 2006 Aug; 52(8):1624-5. PubMed ID: 16873314
    [No Abstract]   [Full Text] [Related]  

  • 76. A demonstration of the structure and disposition of ferritin in the human liver cell.
    KERR DN; MUIR AR
    J Ultrastruct Res; 1960 Feb; 3():313-9. PubMed ID: 14408633
    [No Abstract]   [Full Text] [Related]  

  • 77. High ferritin concentration in acute liver failure: The top of the iceberg?
    Brito-Azevedo A
    Liver Int; 2018 Jan; 38(1):190. PubMed ID: 28941305
    [No Abstract]   [Full Text] [Related]  

  • 78. Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis.
    Garcia-Casal MN; Peña-Rosas JP; Urrechaga E; Escanero JF; Huo J; Martinez RX; Lopez-Perez L
    PLoS One; 2018; 13(5):e0196576. PubMed ID: 29723227
    [TBL] [Abstract][Full Text] [Related]  

  • 79. Calibration of Abbott AxSYM Ferritin kit using the WHO Human Liver Ferritin International Standard 80/602.
    Milman N; Juul-Jørgensen B; Bentzon MW
    Eur J Clin Chem Clin Biochem; 1997 Aug; 35(8):631-2. PubMed ID: 9298354
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Calibration of the Amersham Ferritin RIA kit using the WHO human liver ferritin international standard 80/602.
    Milman N; Graudal N; Juul-Jørgensen B; Bentzon MW
    Eur J Clin Chem Clin Biochem; 1994 Jan; 32(1):41-2. PubMed ID: 8167193
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 5.