These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 9308533)

  • 1. Shelf life and in vivo duration. Impacts on performance of tibial bearings.
    Currier BH; Currier JH; Collier JP; Mayor MB; Scott RD
    Clin Orthop Relat Res; 1997 Sep; (342):111-22. PubMed ID: 9308533
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo oxidation of gamma-barrier-sterilized ultra-high-molecular-weight polyethylene bearings.
    Currier BH; Currier JH; Mayor MB; Lyford KA; Van Citters DW; Collier JP
    J Arthroplasty; 2007 Aug; 22(5):721-31. PubMed ID: 17689783
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Overview of polyethylene as a bearing material: comparison of sterilization methods.
    Collier JP; Sutula LC; Currier BH; Currier JH; Wooding RE; Williams IR; Farber KB; Mayor MB
    Clin Orthop Relat Res; 1996 Dec; (333):76-86. PubMed ID: 8981883
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Oxidation-induced dynamic changes in morphology reflected on freeze-fractured surface of gamma-irradiated ultra-high molecular weight polyethylene components.
    Watanabe E; Suzuki M; Nagata K; Kaneeda T; Harada Y; Utsumi M; Mori A; Moriya H
    J Biomed Mater Res; 2002 Dec; 62(4):540-9. PubMed ID: 12221702
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Gamma-irradiation sterilization in an inert environment: a partial solution.
    Berry DJ; Currier BH; Mayor MB; Collier JP
    Clin Orthop Relat Res; 2012 Jul; 470(7):1805-13. PubMed ID: 22033874
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Otto Aufranc Award. Impact of gamma sterilization on clinical performance of polyethylene in the hip.
    Sutula LC; Collier JP; Saum KA; Currier BH; Currier JH; Sanford WM; Mayor MB; Wooding RE; Sperling DK; Williams IR
    Clin Orthop Relat Res; 1995 Oct; (319):28-40. PubMed ID: 7554641
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Coventry Award. The effects of shelf life on clinical outcome for gamma sterilized polyethylene tibial components.
    Bohl JR; Bohl WR; Postak PD; Greenwald AS
    Clin Orthop Relat Res; 1999 Oct; (367):28-38. PubMed ID: 10546595
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Unilateral tibial polyethylene liner failure in bilateral total knee arthroplasty--bilateral retrieval analysis at 8 years.
    Burnett RS; Biggerstaff S; Currier BH; Collier JP; Barrack RL
    J Arthroplasty; 2007 Aug; 22(5):753-8. PubMed ID: 17689787
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantifying the effect of resin type and sterilization method on the degradation of ultrahigh molecular weight polyethylene after 4 years of real-time shelf aging.
    Willie BM; Ashrafi S; Alajbegovic S; Burnett T; Bloebaum RD
    J Biomed Mater Res A; 2004 Jun; 69(3):477-89. PubMed ID: 15127395
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A study of the combined effects of shelf ageing following irradiation in air and counterface roughness on the wear of UHMWPE.
    Besong AA; Hailey JL; Ingham E; Stone M; Wroblewski BM; Fisher J
    Biomed Mater Eng; 1997; 7(1):59-65. PubMed ID: 9171903
    [TBL] [Abstract][Full Text] [Related]  

  • 11. In vivo degradation of polyethylene liners after gamma sterilization in air.
    Kurtz SM; Rimnac CM; Hozack WJ; Turner J; Marcolongo M; Goldberg VM; Kraay MJ; Edidin AA
    J Bone Joint Surg Am; 2005 Apr; 87(4):815-23. PubMed ID: 15805212
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Crosslink density, oxidation and chain scission in retrieved, highly cross-linked UHMWPE tibial bearings.
    Reinitz SD; Currier BH; Levine RA; Van Citters DW
    Biomaterials; 2014 May; 35(15):4436-40. PubMed ID: 24589360
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide.
    Ries MD; Weaver K; Rose RM; Gunther J; Sauer W; Beals N
    Clin Orthop Relat Res; 1996 Dec; (333):87-95. PubMed ID: 8981884
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In vivo oxidation in remelted highly cross-linked retrievals.
    Currier BH; Van Citters DW; Currier JH; Collier JP
    J Bone Joint Surg Am; 2010 Oct; 92(14):2409-18. PubMed ID: 20962191
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gamma inert sterilization: a solution to polyethylene oxidation?
    Medel FJ; Kurtz SM; Hozack WJ; Parvizi J; Purtill JJ; Sharkey PF; MacDonald D; Kraay MJ; Goldberg V; Rimnac CM
    J Bone Joint Surg Am; 2009 Apr; 91(4):839-49. PubMed ID: 19339568
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty.
    Collier MB; Engh CA; McAuley JP; Engh GA
    J Bone Joint Surg Am; 2007 Jun; 89(6):1306-14. PubMed ID: 17545435
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Sterilization and polyethylene wear: clinical studies to support laboratory data.
    Sychterz CJ; Orishimo KF; Engh CA
    J Bone Joint Surg Am; 2004 May; 86(5):1017-22. PubMed ID: 15118047
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of fabrication method and resin type on performance of tibial bearings.
    Currier BH; Currier JH; Collier JP; Mayor MB
    J Biomed Mater Res; 2000; 53(2):143-51. PubMed ID: 10713560
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Conventional ultra-high molecular weight polyethylene: a gold standard of sorts.
    Engh CA; Sychterz CJ; Engh CA
    Instr Course Lect; 2005; 54():183-7. PubMed ID: 15948445
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accelerated aging studies of UHMWPE. I. Effect of resin, processing, and radiation environment on resistance to mechanical degradation.
    Edidin AA; Herr MP; Villarraga ML; Muth J; Yau SS; Kurtz SM
    J Biomed Mater Res; 2002 Aug; 61(2):312-22. PubMed ID: 12007212
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.