These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

114 related articles for article (PubMed ID: 9309739)

  • 1. Impact of programmed sensitivity safety factor on atrial sensing in children.
    Chiu CC; Gow RM; McCrindle BW; Hamilton RM
    Pacing Clin Electrophysiol; 1997 Sep; 20(9 Pt 1):2163-70. PubMed ID: 9309739
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Should unipolar leads be implanted in the atrium? A Holter electrocardiographic comparison of threshold adapted unipolar and high sensitive bipolar sensing.
    Wiegand UK; Schier H; Bode F; Brandes A; Potratz J
    Pacing Clin Electrophysiol; 1998 Aug; 21(8):1601-8. PubMed ID: 9725160
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Unipolar sensing in contemporary pacemakers: using myopotential testing to define optimal sensitivity settings.
    Exner DV; Rothschild JM; Heal S; Gillis AM
    J Interv Card Electrophysiol; 1998 Mar; 2(1):33-40. PubMed ID: 9869994
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Complicated Holter tracing with an incidence of inappropriate mode switch due to sensing abnormalities in a patient with dual-chamber pacemaker.
    Poręba M; Karczmarewicz S; Szwarc B; Sobieszczańska M; Wranicz JK
    Cardiol J; 2011; 18(1):94-6. PubMed ID: 21305495
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Diagnosis of atrial undersensing in dual chamber pacemakers: impact of autodiagnostic features.
    Wiegand UK; Bode F; Schneider R; Brandes A; Haase H; Katus HA; Potratz J
    Pacing Clin Electrophysiol; 1999 Jun; 22(6 Pt 1):894-902. PubMed ID: 10392387
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparative evaluation of acute and long-term clinical performance of two single lead atrial synchronous ventricular (VDD) pacemakers: diagonally arranged bipolar versus closely spaced bipolar ring electrodes.
    Lau CP; Leung SK; Lee IS
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 1):1574-81. PubMed ID: 8946453
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of autosensing as an automatic means of maintaining a 2:1 sensing safety margin in an implanted pacemaker. Autosensing Investigation Team.
    Castro A; Liebold A; Vincente J; Dungan T; Allen JC
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1708-13. PubMed ID: 8945028
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pacing and sensing disturbances in patients with DDD pacemakers in the early period after implantation.
    Wranicz JK; Chudzik M; Cygankiewicz I; Klimczak A; Kaczmarek K; Maciejewski M; Goch JH
    Acta Cardiol; 2006 Jun; 61(3):289-94. PubMed ID: 16869449
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Spontaneous daily variability of atrial sensitivity. A study with an implanted DDD pacemaker.
    Romanò M; Spinelli A; Grieco A
    Int J Cardiol; 2001 Feb; 77(2-3):287-91. PubMed ID: 11182194
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Efficacy and safety of bipolar sensing with high atrial sensitivity in dual chamber pacemakers.
    Wiegand UK; Bode F; Peters W; Haase H; Bonnemeier H; Katus HA; Potratz J
    Pacing Clin Electrophysiol; 2000 Apr; 23(4 Pt 1):427-33. PubMed ID: 10793429
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implantation strategy of the atrial dipole impacts atrial sensing performance of single lead VDD pacemakers.
    Wiegand UK; Nowak B; Reisp U; Peiffer T; Bode F; Potratz J;
    Pacing Clin Electrophysiol; 2002 Mar; 25(3):316-23. PubMed ID: 11990661
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous Holter telemetry of atrial electrograms and marker annotations using a common Holter recording system: impact on Holter electrocardiogram interpretation in patients with dual chamber pacemakers.
    Wiegand UK; Bonnemeier H; Bode F; Eberhardt F; Chun JK; Katus HA; Peters W
    Pacing Clin Electrophysiol; 2002 Dec; 25(12):1724-30. PubMed ID: 12520673
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reliability of an automatic sensing algorithm.
    Berg M; Fröhlig G; Schwerdt H; Becker R; Schieffer H
    Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 2):1880-5. PubMed ID: 1279564
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bipolar ventricular far-field signals in the atrium.
    Fröhlig G; Helwani Z; Kusch O; Berg M; Schieffer H
    Pacing Clin Electrophysiol; 1999 Nov; 22(11):1604-13. PubMed ID: 10598963
    [TBL] [Abstract][Full Text] [Related]  

  • 15. First experience with an automatic sensing algorithm in single-lead VDD stimulation.
    Nowak B; Fellmann P; Maertens S; Mols R; Demetz K; Brüls A; Geil S; Voigtländer T; Himmrich E; Meyer J
    Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 2):2232-5. PubMed ID: 9825324
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Unipolar sensing abnormalities: incidence and clinical significance of skeletal muscle interference and undersensing in 228 patients.
    Secemsky SI; Hauser RG; Denes P; Edwards LM
    Pacing Clin Electrophysiol; 1982 Jan; 5(1):10-9. PubMed ID: 6181460
    [TBL] [Abstract][Full Text] [Related]  

  • 17. VVI pacemaker ventricular undersensing.
    Johnson CD
    Bol Asoc Med P R; 1986 Jan; 78(1):21-5. PubMed ID: 3456750
    [No Abstract]   [Full Text] [Related]  

  • 18. [Atrioventricular block/sick sinus syndrome].
    Ishikawa T; Umemura S
    Nihon Rinsho; 2002 Jul; 60(7):1401-7. PubMed ID: 12136621
    [TBL] [Abstract][Full Text] [Related]  

  • 19. How reliable is atrial sensing in single-lead VDD pacing: comparison of three systems.
    Nowak B; Middeldorf T; Voigtländer T; Rosocha S; Liebrich A; Zellerhoff C; Przibille O; Himmrich E; Meyer J
    Pacing Clin Electrophysiol; 1998 Nov; 21(11 Pt 2):2226-31. PubMed ID: 9825323
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-term stability of P wave sensing in single lead VDDR pacing: clinical versus subclinical atrial undersensing.
    Lau CP; Tai YT; Leung SK; Leung WH; Chung FL; Lee IS
    Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):1849-53. PubMed ID: 7845779
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.